Solitaire FR Stent as an Adjunctive Tool for Pipeline Stent Deployment in the Treatment of Giant Intracranial Aneurysms

2012 ◽  
Vol 72 (2) ◽  
pp. ons241-ons244
Author(s):  
Frédéric Clarençon ◽  
Gerald Wyse ◽  
Noel Fanning ◽  
Federico Di Maria ◽  
André Gaston ◽  
...  

Abstract BACKGROUND AND IMPORTANCE: The use of flow-diverting stents has gained acceptance during the past few years for the treatment of numerous intracranial aneurysms, especially large or giant ones. However, successful catheterization of the distal parent artery in giant intracranial aneurysms with a microcatheter can be extremely challenging. Forming a microcatheter loop in the aneurysm sac can aid distal catheterization. CLINICAL PRESENTATION: We report the use of a Solitaire FR stent as an adjunctive tool in the successful treatment of 2 giant intracranial unruptured aneurysms with a Pipeline Embolization Device. After having formed a loop inside the aneurysm sac, the microcatheter was anchored distally by a Solitaire FR stent. With the Solitaire FR device opened, the loop in the giant aneurysm sac was completely reduced without loss of the microcatheter position in the distal parent artery. A Pipeline Embolization Device could be delivered in both cases without any difficulty. There were no complications. CONCLUSION: The technique described results in ideal microcatheter alignment with a secure distal position before deployment of a flow-diverting stent.

1999 ◽  
Vol 5 (1_suppl) ◽  
pp. 93-96 ◽  
Author(s):  
C.F. Dowd ◽  
C.C. Phatouros ◽  
A.M. Malek ◽  
T.E. Lempert ◽  
P.M. Meyers ◽  
...  

Options for treatment of intracranial aneurysms have expanded with the advent of the Guglielmi Detachable Cod (GDC) eight years ago. We have reviewed 435 cases of intracranial aneurysms treated at UCSF by endovascular means using the GDC system. Of these, 55% represent anterior circulation aneurysms, and 45% are located in the posterior circulation. Additionally, 55% of the aneurysms presented with subarachnoid hemorrhage (SAH) and 45% were unruptured. Factors which hindered optimal coiling include the following: wide aneurysm neck in relation to the overall aneurysm size, mural thrombus, giant aneurysm, arteries originating from the aneurysm sac, and middle cerebral location. After initial experience was gained, we tended to avoid these aneurysms especially in the non-ruptured group. This may be especially important in light of new epidemiological data suggesting that the natural history of unruptured aneurysms is significantly lower than previously thought. New technical developments which may reduce the risk of treating unruptured aneurysms include the two-dimensional coil, the three-dimensional coil, the balloon-assist technique for wide-necked aneurysms, and combined stent-coil procedures.


1998 ◽  
Vol 4 (1) ◽  
pp. E1 ◽  
Author(s):  
Vini G. Khurana ◽  
David G. Piepgras ◽  
Jack P. Whisnant

Object The present study was conducted to estimate the frequency and timing of rebleeding after initial subarachnoid hemorrhage (SAH) from ruptured giant aneurysms. Methods The authors reviewed records of 109 patients who suffered an initial SAH from a giant aneurysm and were treated at the Mayo Clinic between 1973 and 1996. They represented 25% of patients with giant intracranial aneurysms seen at this institution during that 23-year period. Seven of the patients were residents of Rochester, Minnesota, and the rest were referred from other institutions. The aneurysms ranged from 25 to 60 mm in diameter, and 74% were located on arteries of the anterior intracranial circulation. The cumulative frequency of rebleeding at 14 days after admission was 18.4%. Cerebrospinal fluid drainage, cerebral angiography, and delayed aneurysm recurrence were implicated in rebleeding in some of the patients. Rebleeding was not precluded by intraaneurysm thrombosis. Among those who suffered recurrent SAH at the Mayo Clinic, 33% died in the hospital. Conclusions Rebleeding from giant aneurysms occurs at a rate comparable to that associated with smaller aneurysms, a finding that should be considered in management strategies.


Neurosurgery ◽  
2006 ◽  
Vol 58 (3) ◽  
pp. 443-450 ◽  
Author(s):  
Bernhard Kis ◽  
Werner Weber ◽  
Peter Berlit ◽  
Dietmar Kühne

Abstract OBJECTIVE: Endovascular coil embolization of saccular intracranial aneurysms is safe and effective, but long-term results are dissatisfying. Reconstructive treatments using stents improve occlusion rate and protect parent vessels. We present data on our experience with a new self-expanding stent manufactured with braided nitinol wires. METHODS: Twenty-five saccular, complex, and broad-necked intracranial aneurysms in 21 patients were treated electively. They were located at the internal carotid artery (10), basilar trunk (5), cavernous carotid artery (4), basilar tip (2), anterior cerebral artery (2), anterior communicating artery (1), and middle cerebral artery (1). Eleven aneurysms exhibited recanalization after primary endovascular treatment without stent. RESULTS: Stent deployment was successful in 24 lesions, and additional coil embolization was performed in 23. No permanent neurological deficits were encountered consequent to endovascular procedure. Complete or partial occlusion immediately after stent deployment was achieved in 19 aneurysms, whereas no immediate coil embolization was chosen in 6 cases. There were two thromboembolic events related to the deployment of the Leo stent, one failure of stent deployment, difficulties in stent positioning in three cases, and one asymptomatic parent artery occlusion after 7 months. Follow-up (available in 18 patients and 21 aneurysms and obtained at 3–12 mo; average, 5 mo) revealed patent stents in the remaining cases. Angiographic recurrences arose in three lesions, which were retreated without complications. CONCLUSION: Primary and recurrence treatment of saccular and broad-necked intracranial aneurysms using the Leo stent is feasible and effective. No permanent neurological deficits were associated with stent placement. Short-term follow-up identified intact parent arteries and stable occlusion rates in the majority of cases.


2020 ◽  
Vol 12 (11) ◽  
pp. 1107-1112 ◽  
Author(s):  
Hal Rice ◽  
Mario Martínez Galdámez ◽  
Markus Holtmannspötter ◽  
Laurent Spelle ◽  
Konstantinos Lagios ◽  
...  

BackgroundThe first and second generations of the Pipeline Embolization Device (PED) have been widely adopted for the treatment of intracranial aneurysms (IAs) due to their high associated occlusion rates and low morbidity and mortality. The objective of this study was to evaluate the safety and effectiveness of the third- generation Pipeline Shield device (PED-Shield) for the treatment of IAs.MethodsThe SHIELD study was a prospective, single-arm, multicenter, post-market, observational study evaluating the PED-Shield device for the treatment of IAs. The primary efficacy endpoint was complete aneurysm occlusion without significant parent artery stenosis or retreatment at 1-year post-procedure and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurological death.ResultsOf 205 subjects who consented across 21 sites, 204 subjects with 204 target aneurysms were ultimately treated (mean age 54.8±12.81 years, 81.4% [166/204] female). Technical success (ie, deployment of the PED-Shield) was achieved in 98.0% (200/204) of subjects with a mean number of 1.1±0.34 devices per subject and a single device used in 86.8% (177/204) of subjects. The primary effectiveness endpoint was met in 71.7% (143/200) of subjects while the primary safety endpoint occurred in six (2.9%) subjects, two (1.0%) of which led to neurological death.ConclusionsThe findings of the SHIELD study support the safety and effectiveness of the PED-Shield for IA treatment, evidenced by high occlusion rates and low rates of neurological complications in the study population.Clinical trial registration-URLhttp://www.clinicaltrials.gov. Unique identifier: NCT02719522.


2015 ◽  
Vol 3 (3-4) ◽  
Author(s):  
Alice Venier ◽  
Beatrice Gardenghi ◽  
Giuseppe Lanzino ◽  
Stylianos K. Rammos

AbstractThe progressive establishment of endovascular management in treating intracranial aneurysms had lead to continuous technique advancements and development of innovative technologies. Flow diverters are “stent-like” devices currently used for complex unruptured aneurysms allowing endoluminal reconstruction of the parent artery and occlusion of the aneurysm sac. In the present article, we review the development of flow diversion devices through


1998 ◽  
Vol 88 (3) ◽  
pp. 425-429 ◽  
Author(s):  
Vini G. Khurana ◽  
David G. Piepgras ◽  
Jack P. Whisnant

Object. The present study was conducted to estimate the frequency and timing of rebleeding after initial subarachnoid hemorrhage (SAH) from ruptured giant aneurysms. Methods. The authors reviewed records of 109 patients who suffered an initial SAH from a giant aneurysm and were treated at the Mayo Clinic between 1973 and 1996. They represented 25% of patients with giant intracranial aneurysms seen at this institution during that 23-year period. Seven of the patients were residents of Rochester, Minnesota, and the rest were referred from other institutions. The aneurysms ranged from 25 to 60 mm in diameter, and 74% were located on arteries of the anterior intracranial circulation. The cumulative frequency of rebleeding at 14 days after admission was 18.4%. Cerebrospinal fluid drainage, cerebral angiography, and delayed aneurysm recurrence were implicated in rebleeding in some of the patients. Rebleeding was not precluded by intraaneurysm thrombosis. Among those who suffered recurrent SAH at the Mayo Clinic, 33% died in the hospital. Conclusions. Rebleeding from giant aneurysms occurs at a rate comparable to that associated with smaller aneurysms, a finding that should be considered in management strategies.


Neurosurgery ◽  
2011 ◽  
Vol 70 (3) ◽  
pp. 617-624 ◽  
Author(s):  
Olli I. Tähtinen ◽  
Hannu I. Manninen ◽  
Ritva L. Vanninen ◽  
Janne Seppänen ◽  
Tero Niskakangas ◽  
...  

Abstract Background: The flow-diverting stent is a new option in endovascular therapy specifically designed for the endovascular reconstruction of a segmentally diseased artery. The safety of flow-diverting stents is still equivocal. Objective: To evaluate the technical aspects, thromboembolic events, adjunctive therapies, and midterm results in patients with complex intracranial aneurysms treated with a flow-diverting stent (Silk; Balt Extrusion, Montmorency, France). Methods: We retrospectively examined angiographic images and clinical reports of 24 consecutive patients (29 stents) treated (n = 23) or attempted to treat (n = 1) with a flow-diverting device in 2 Finnish centers between March 2009 and October 2010. Results: The primary technical success rate was 67% (16/24). Adjunctive therapies were required in 6 (25%) patients, including 4 cases where intra-arterial abciximab was administered for the treatment of intraprocedural thromboembolic events. Technique-related complication rate and the 30-day mortality rate were each 4% (1/24). Follow-up imaging revealed 1 case of delayed in-stent thrombosis resulting in permanent disability of the patient, 1 asymptomatic occlusion, and 1 asymptomatic stenosis of the stented artery. Complete occlusion of the aneurysm with fully patent parent artery was observed in 16 of the 23 aneurysms (70%) where follow-up images were available. Conclusion: Many previously untreatable cerebral aneurysms may be successfully treated with the Silk flow-diverting stent, but the associated risk of thromboembolic events is justifiable only if conventional endovascular or surgical treatment options are not applicable. Perioperative thromboembolic events should be prepared for and treated without unnecessary delays because they frequently respond to adjunctive medical therapy.


2019 ◽  
Vol 11 (6) ◽  
pp. 591-597 ◽  
Author(s):  
Tanja Djurdjevic ◽  
Victoria Young ◽  
Rufus Corkill ◽  
Dennis Briley ◽  
Wilhelm Küker

Background and purposeLow profile braided stents have facilitated the endovascular treatment of broad-based intracranial aneurysms.MethodsBetween 2013 and June 2018, we attempted 104 Leo baby stent placements in 101 patients. Locations were the anterior communicating artery (AcomA) (37 aneurysms, 35.6%), middle cerebral artery (MCA) bifurcation (29 aneurysms, 27.9%) and basilar artery (23aneurysms, 22.1%). Mean neck size was 4.9 mm (2.2–8.2). 60 aneurysms were incidental, 31 of 37 recurrent aneurysms had ruptured before.ResultsStent deployment was successful in 89.4% of cases. Common reasons for failure were inability to access the parent artery (n=5) or to deploy the stent across the aneurysm neck (n=4). Two patients had poor outcomes within 24 hours. One patient developed a brain hemorrhage caused by guide wire perforation (MRS 5), the other an early thrombotic stent occlusion (MRS 4). No patient died. Nine (8.7%) patients experienced transient neurological deficits with ischemic lesions on diffusion weighted imaging (DWI). Initially Raymond-Roy class 1 occlusion was achieved in 23 aneurysms (24.7%), class 2 occlusion in 40 (43%), class 3a occlusion in 14 (15.0%), and 3b occlusion in 16 aneurysms (17.2%). Follow-up imaging in 87 patients showed stable or improved occlusion grades in 76%. Six patients required retreatment while the rest were managed conservatively. Four delayed stent occlusions occurred in three patients, with severe morbidity in one patient (MRS 5). There were no aneurysm ruptures or deaths.ConclusionStent assisted treatment of broad-based aneurysms with the Leo baby stent is safe and effective. The frequency of delayed thrombotic complications is low and similar to other stents.


Sign in / Sign up

Export Citation Format

Share Document