Fourth Report of the Wire Ropes Research Committee

1930 ◽  
Vol 118 (1) ◽  
pp. 553-602 ◽  
Author(s):  
W. A. Scoble
1935 ◽  
Vol 130 (1) ◽  
pp. 373-478 ◽  
Author(s):  
W. A. Scoble

The present Report, like those which have preceded it, includes results which can be divided into two sections. The work of the first section follows from data recorded in earlier Reports. The Fourth Report included test results for ropes of 2 inches circumference which were tested on the larger machines, whilst the facilities for handling larger ropes allowed those consisting of more wires to be tested, since these more flexible constructions are not generally made of 1 inch circumference. Rope 20 of 2 inches circumference, 6 × 19, was included for comparison with the earlier 1-inch ropes of similar construction to indicate the importance or otherwise of the scale effect. The 2-inch rope was somewhat inferior to the poorer of two 6 × 19 1-inch ropes, Nos. 10 and 14, which differed appreciably in performance. Comparison of two 6 × 19 Trulay ropes, one about three times as large as the other, confirmed the superior life of a small compared with a large rope under corresponding conditions. Nos. 10 and 14 showed that appreciable differences may be met with in ropes supposed to be similar, so it was thought that the apparent inferiority of the larger rope was partly due to the fact that No. 20 belonged to the lower region of the range of performance which may be anticipated. Another 6 × 19 rope of 2 inches circumference, No. 26, of the same tensile strength as No. 20, was available, so it was tested to check this supposition and the probable range of behaviour. A few further tests of the 2–inch circumference ropes, arranged 6 × 19, 6 × 24, and 6 × 37, were made under more severe conditions than were covered by the data of the Fourth Report. The investigation of the effect of rope speed was carried a stage further by an attempt to discover whether slip between rope and pulley was a possible cause of a reduction of rope life at higher speeds. The lubrication of ropes has been the subject of more detailed study and an Appendix by Mr. P. G. Taigel, B.Sc. (Eng.), G.I.Mech.E., is included giving the results of many experiments and throwing further light on this important matter. The second section of the Report records the results of new work which, although it is necessarily related to, is not merely an extension of, the earlier experiments. Three flattened-strand ropes of different but typical constructions were fully tested over pulleys. A set of ropes made from the same wire but in 6 × 7, 6 × 19, 6 × 24, and 6 × 37 constructions was tested to confirm whether the pulley diameter should be related to the wire or to the rope diameter. Of another set of three ropes of similar construction and size, two were of wire having tensile strengths of 80–90 and 100–110 tons per sq. in. respectively, obtained by drawing, and the third was of wire of 80–90 tons per sq. in. tensile strength, secured by heat treatment, to confirm the effect of the tensile strength of the wire on the life of ropes and to determine whether heat-treated wire was as good as drawn wire. These ropes were made under the supervision of Mr. A. T. Adam, of Messrs. Bruntons, and were prepared for tests in connexion with his questions in the Discussion on the last Report. Experiments were carried out on a new machine designed to represent ropeway conditions. A rope under tension was traversed by a pulley taking a lateral load which caused the rope to bend through a small angle at the pulley. Comparative tests of ropes on chilled and ordinary cast iron pulleys were followed by similar tests on pulleys made of other metals or with linings at the tread. In most of the constructions dealt with, ropes were examined under an empirical static bending test and the measurements made were plotted and analysed. Little is said about the wire itself because, although more time and work have been devoted to it than to the complete ropes, many results have been negative, whilst experience has shown that hasty conclusions are likely to be wrong. It is considered that the new tests developed during this research should be given further trial before they are recommended for general use. This being the final Report of the Committee, the opportunity is taken to review the conclusions which have been drawn from time to time, and an attempt is made to stress the practical bearing of some of them.


2013 ◽  
Vol 423-426 ◽  
pp. 842-845 ◽  
Author(s):  
Zhi Hui Hu ◽  
Yong Hu ◽  
Ji Quan Hu

Based on the analysis of multi-layer winding arrangement characteristic of the wire rope in Lebus drum, the experimental study is carried on wear distribution of the wire rope in parallel grooved multi-layer winding. The result shows that, the wire rope is arranged regularly in each drum area in parallel grooved multi-layer winding; the wear of wire ropes in crossover zone is more serious than that of the parallel zone; in the same-layer wire rope winding in crossover zone, the wear damage during the wire rope winding in crossover zone at the end of each-layer drum is the most serious.


1895 ◽  
Vol 58 (347-352) ◽  
pp. 265-468 ◽  

During the progress of my investigation of the bacterial flora of the River 'l'hames, I have frequently isolated from the water a Rchizomycete, which turns out to be in many respects one of the most interesting forms yet met with, and probably one of the most instructive species yet known to science. It occurs at all seasons, more or less, but oftenest during the autumn and winter months, and is found on the isolation plates as white colonies, becoming yellowish with age, which rapidly develop into large membranous growths, so like tho mycelium of a fine mould that it is quite conceivable, or even probable in some cases, observers might pass it by as a small mucor or other fungus, not belonging to the schizomycetes at all.


Author(s):  
Anil Babu Seelam ◽  
Mohammad Saif Jawed ◽  
Sachidananda Hassan Krishanmurthy

In this research paper design and analysis of wire ropes used in elevator have been presented. The main objective of this study is to find the best practices on handling wire ropes for safety and to reduce the downtime of elevators due to wire rope failures. Design calculations have been done to calculate the apt dimensions and design is constructed on Auto Desk inventor software and the analysis have been performed using Ansys. Two configurations of the wire ropes have been studied and from this result it can be concluded that the design of wire rope is possible to relieve mechanical handling and to improve the design of wire ropes making it more durable by possible inclusion of new materials which in turn increases the efficiency and life of wire ropes without compromising safety.


Sign in / Sign up

Export Citation Format

Share Document