scholarly journals Effect of vapor- and liquid-phase radiation grafting on water permeability of porous hollow-fiber membrane.

1988 ◽  
pp. 212-216 ◽  
Author(s):  
Hideyuki YAMAGISAI ◽  
Kyoichi SAITO ◽  
Shintaro FURUSAKI ◽  
Takanobu SUGO ◽  
Jiro OKAMOTO
2013 ◽  
Vol 675 ◽  
pp. 260-263 ◽  
Author(s):  
Du Shu Huang ◽  
Ya Shun Chen ◽  
He Ping Yan ◽  
Na Wu ◽  
Wei Liu ◽  
...  

A novel method for determination of organochlorine pesticides residuals (2,4-DDT and 4,4-DDT) in water samples through hollow fiber membrane-liquid phase microextraction using ionic liquid material as extractant coupled with high performance liquid chromatography has been developed. The effect of extraction parameters including pH of the feed solution, stirring rate and extraction time was investigated. The proposed method provided enrichment efficiency of 323 and 289 for 2,4-DDT and 4,4-DDT respectively. The method had good linear range of 0.5-50 μg /L and the limits of detection of the pesticides were 0.1 μg /L.


2018 ◽  
Vol 19 (4) ◽  
pp. 716-725 ◽  

Sulfur dioxide (SO2) emissions lead to negative environmental impacts and it is considered as an indicator for the larger group of gaseous sulfur oxides (SOx) in the air. In this paper, the dimethylamine (DMA) solution was used as the absorbent in a α-Al2O3 hollow fiber membrane contactor that is operated under several conditions of gas velocity, liquid velocity, and 290 K operating temperature. The effects of gas and liquid phase properties and module configuration on SO2 absorption efficiency in the hollow fiber membrane contactor were investigated. Simulation results showed that the changes of gas phase velocity, liquid phase velocity, and concentration have great influences on the absorption efficiency of SO2. An increase of the gas flow rate decreases the SO2 absorption efficiency, while an increase of the liquid flow rate has the opposite effect, increasing the efficiency. Because gas in the membrane module stays for a longer time, more absorption time promotes the gas and liquid reaction. However, the changes of the volume fraction of SO2 in the mixed gas are not significant to SO2 absorption. The simulation model could provide guidelines for selecting suitable fluid properties during the SO2 absorption process in a hollow fiber membrane contactor.


2012 ◽  
Vol 51 (43) ◽  
pp. 14199-14208 ◽  
Author(s):  
Ksenija R. Kumrić ◽  
Goran T. Vladisavljević ◽  
Tatjana M. Trtić-Petrović

Sign in / Sign up

Export Citation Format

Share Document