scholarly journals A Specific and Sensitive Assay for Gefitinib Using the Enzyme-Linked Immunosorbent Assay in Human Serum

2005 ◽  
Vol 28 (10) ◽  
pp. 1833-1837 ◽  
Author(s):  
Tetsuya Saita ◽  
Hiroshi Fujito ◽  
Masato Mori
mSphere ◽  
2018 ◽  
Vol 3 (4) ◽  
pp. e00128-18 ◽  
Author(s):  
Danka Pavliakova ◽  
Peter C. Giardina ◽  
Soraya Moghazeh ◽  
Shite Sebastian ◽  
Maya Koster ◽  
...  

ABSTRACT A Luminex-based direct immunoassay (dLIA) platform has been developed to replace the standardized pneumococcal enzyme-linked immunosorbent assay platform. The multiplex dLIA simultaneously measures the concentration of serum immunoglobulin G (IgG) antibodies specific for pneumococcal capsular polysaccharide (PnPS) serotypes 1, 3, 4, 5, 6A, 6B, 7F, 9V, 14, 18C, 19A, 19F, and 23F. The assay uses poly-l-lysine (PLL)-conjugated PnPS, chemically coupled to spectrally distinct Luminex microspheres. Assay validation experiments were performed using residual human serum samples obtained from 13-valent pneumococcal conjugate vaccine (13vPnC) clinical studies. Assay results are expressed as IgG antibody concentrations in micrograms per milliliter using the international reference serum, 007sp. The lower limit of quantitation (LLOQ) for all serotypes covered in the 13-plex dLIA fell within the range of 0.002 to 0.038 µg/ml serum IgG. The difference between the lower limit and upper limit of the assay range was >500-fold for all serotypes, and assay variability was <20% relative standard deviation (RSD) for all serotypes. IgG antibody measurements were shown to be serotype-specific (some cross-reactivity was observed only between the structurally related serotypes 6A and 6B as well as 19A and 19F), and no interference was observed between the serotypes when the assay was performed in the 13-plex format compared to the singleplex assays. The 13-plex dLIA platform developed by Pfizer Inc. generates up to 143 test results in a single 96-well plate and is a suitable replacement of the enzyme-linked immunosorbent assay (ELISA) platform for evaluating vaccine clinical trials. IMPORTANCE The pneumococcal enzyme-linked immunosorbent assay (ELISA) measures IgG antibodies in human serum, and it is an important assay that supports licensure of pneumococcal vaccines. The immune correlate of protection, 0.35 µg/ml of IgG antibodies, was determined by the ELISA method. Pfizer has developed a new Luminex-based assay platform to replace the ELISA. These papers describe the important work of (i) validating the Luminex-based assay and (ii) bridging the immune correlate of protection (0.35 µg/ml IgG) to equivalent values reported by the Luminex platform.


1995 ◽  
Vol 240 (1) ◽  
pp. 1-9 ◽  
Author(s):  
Toshitaka Sato ◽  
Masayoshi Fukasawa ◽  
Makoto Kinoshita ◽  
Hiroyuki Arai ◽  
Takao Saeki ◽  
...  

Steroids ◽  
1985 ◽  
Vol 45 (1) ◽  
pp. 31-38 ◽  
Author(s):  
M. Jawed Iqbal ◽  
Alastair Forbes ◽  
Timothy P. Corbishley ◽  
Mark L. Wilkinson ◽  
Roger Williams

1988 ◽  
Vol 71 (6) ◽  
pp. 1137-1140 ◽  
Author(s):  
Deborah E Dixon-Holland ◽  
Stanley E Katz

Abstract A sensitive assay for the detection of sulfamethazine in swine urine and muscle tissue using a direct competitive enzyme-linked immunosorbent assay (ELISA) has been developed. Undiluted urine or a phosphate-buffered saline extract of pork muscle tissue is mixed with an enzyme-labeled conjugate of sulfamethazine and horseradish peroxidase. The mixture is added to wells of a microtiter plate coated with antibody to sulfamethazine. After the test system is incubated, washed, and re-incubated with substrate and the reaction is stopped, the absorbance is measured at 405 nm. Levels of sulfamethazine as low as 20 ng sulfamethazine/g muscle tissue and 10 ng sulfamethazine/ mL swine urine were detected and estimated


1992 ◽  
Vol 38 (10) ◽  
pp. 1954-1958 ◽  
Author(s):  
S Ogiwara ◽  
K Kiuchi ◽  
T Nagatsu ◽  
R Teradaira ◽  
I Nagatsu ◽  
...  

Abstract An enzyme immunosorbent assay of neopterin and biopterin on a polystyrene microtiter plate has been developed. A conjugate of neopterin or biopterin to bovine serum albumin was used to raise a specific antiserum against neopterin or biopterin in rabbits. An incubation mixture of the antiserum and samples prepared from human serum underwent another antigen-antibody reaction with the hapten fixed on the microtiter plate. The amount of antibody bound to the fixed hapten, which is inverse to the amount of hapten in the sample, was determined by using anti-rabbit IgG-horseradish peroxidase conjugate in a usual manner by measuring absorbance at 490 nm after reaction with o-phenylenediamine and hydrogen peroxide. The minimal detectable amounts of neopterin and biopterin were approximately 0.1 pmol. The specificity of the assay was so high that the assay system for neopterin completely distinguished it from biopterin, as judged from the cross-reaction of 0.002%, and vice versa. The amounts of neopterin and biopterin in human serum determined by the present method agreed well with those determined by high-performance liquid chromatography. We used the present method to determine the concentrations of neopterin in serum from healthy control subjects and patients with cancers and systemic lupus erythematosus; the results were consistent with literature data.


2017 ◽  
Vol 58 (8) ◽  
pp. 1591-1597 ◽  
Author(s):  
Kazuya Miyashita ◽  
Katsuyuki Nakajima ◽  
Isamu Fukamachi ◽  
Yuji Muraba ◽  
Takafumi Koga ◽  
...  

2009 ◽  
Vol 391 (2) ◽  
pp. 114-120 ◽  
Author(s):  
Carola W.N. Damen ◽  
Els R. de Groot ◽  
Marianne Heij ◽  
David S. Boss ◽  
Jan H.M. Schellens ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document