scholarly journals Concurrent Posterolateral Corner Injury Associated with a Schatzker Type 2 Tibial Plateau Fracture: A Case Report

2020 ◽  
Vol 33 (1) ◽  
pp. 27
Author(s):  
Jae Cheon Sim ◽  
Choong Won Jung ◽  
Tae Seok Nam
2015 ◽  
Vol 2015 ◽  
pp. 1-5
Author(s):  
Boris A. Zelle ◽  
James R. Heaberlin ◽  
Matthew C. Murray

Isolated posterolateral corner (PLC) injuries are rarely seen with tibial plateau fractures and can be missed during the initial assessment. The objective of this paper is to present a case of a Schatzker type 2 tibial plateau fracture with associated isolated PLC injury and give a discussion on physical exam, diagnostic studies, and treatment options. A twenty-five-year-old female sustained a concomitant Schatzker type 2 fracture and PLC injury. Magnetic Resonance Imaging showed an isolated PLC disruption. Open reduction-internal fixation was performed with subsequent PLC repair. At sixteen months postoperatively, the patient had full range of motion and strength of her knee and no signs of laxity. This case emphasizes the importance of physical exam and appropriate imaging modalities in order to diagnose and treat this significant injury in a prompt fashion. In this case, surgical fracture fixation and subsequent repair of the PLC provided a good clinical outcome.


Author(s):  
VINCENZO GIORDANO ◽  
WILLIAM DIAS BELANGERO ◽  
BRENNO DE ARAÚJO SÁ ◽  
DANIELA RIVAS ◽  
DANILO SOUTO ◽  
...  

ABSTRACT The aim of this study was to evaluate the biomechanical role of both a non-locking two-hole small fragment dynamic compression plate with 3.5-mm screws and a 4.5-mm cortical screw with a washer applied to a Schatzker type-I tibial plateau fracture. Sixteen right synthetic tibiae were used to create an anterolateral shear tibial plateau fracture (Schatzker type-I fracture). Eight models were fixed with a small fragment non-locked straight dynamic compression plate with one 3.5-mm bicortical screw (plate-screw construction) and eight models were fixed with a 4.5-mm cortical screw and a washer (screw-washer construction), both inserted at 1.0 mm distal to the apex of the fracture. Specimens were tested up to the onset of yielding at a constant strain rate of 5.0-mm/min. Stiffness ranged from 311.83 N/mm to 199.54 N/mm, with a mean + SD of 260.32 + 33.8 N/mm in the plate-screw construction, and from 290.34 N/mm to 99.16 N/mm, with a mean + SD of 220.46 + 63.12 N/mm in screw-washer construction. There was no significant difference (p=0.172). Use of a two-hole small-fragment non-locked plate with one 3.5-mm cortical screw or a 4.5-mm cortical screw with a washer applied at 1.0 mm distal to the apex of the fracture as buttressing present similar stiffness in terms of preventing axial displacement in synthetic tibiae models tested up to the onset of yielding.


Author(s):  
Ujwal S. Ramteke ◽  
Vidyadhar Telang ◽  
Nadir Shah ◽  
Ayush Singh ◽  
Hitesh Mangukiya ◽  
...  

<p class="abstract"><strong>Background:</strong> <span lang="EN-GB">Fractures of proximal tibia involve a major weight-bearing joint and are serious injuries, which, if not treated well, result in functional impairment. To preserve normal knee function one must strive to maintain joint congruity, preserve the normal mechanical axis, ensure joint stability and restore a full range of motion. This is a formidable task to accomplish, especially in the face of associated medical conditions of the patients</span><span lang="EN-IN">.</span></p><p class="abstract"><strong>Methods:</strong> <span lang="EN-GB">In our study, 30 cases were selected. Selection of cases were done on the basis of X-rays. Schatzker type I, II, III, IV, V &amp; VI included in study. Criteria for acceptable reduction 1) &lt;5 mm of articular step; 2) &lt;5 mm of articular depression. Each case is referred to one set of tibial plateau fracture, showing distribution of tibia plateau fractures that we treated with MIPPO. Clinical follow-up examination was performed at 4, 6, 10, 12 weeks and 3, 6 months. Clinico-radiological assessment was done at 3 month and grading was done. Patients were evaluated according to grading minimum 3 months after injury</span>.</p><p class="abstract"><strong>Results:</strong> <span lang="EN-GB">Our study of 30 tibial plateau fractures confirms that the MIPPO technique is an excellent treatment modality in case of tibial plateau fractures. We observed these fractures mainly in age group of 30-40 years, which were involved in road traffic accident. Tibial plateau fractures seen in elder age group were mainly due to abnormal loading patterns on the leg. We have found oblique views very much informative especially for posterolateral or posteromedial displacement, articular depression which helps to plan the position and direction of screws to be used for fixation</span><span lang="EN-IN">. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-GB">In view of the excellent results obtained with this technique, we advocate MIPPO over conventional open reduction and internal fixation technique for tibial plateau fracture fixation</span><span lang="EN-IN">.</span></p>


Sign in / Sign up

Export Citation Format

Share Document