Experimental Research on Instability of Phase-Change Heater in Thermal Power Plant

2021 ◽  
Vol 10 (04) ◽  
pp. 426-432
Author(s):  
毅 何
2011 ◽  
Vol 347-353 ◽  
pp. 448-452
Author(s):  
De Qi Peng ◽  
Ya Jie Zhou ◽  
Wei Qiang Wang ◽  
Tian Lan Yu ◽  
Huan Yu ◽  
...  

In order to reduce the pressure drop increase caused by self-rotating plastic twisted-strips in heat transfer tubes of vacuum condensers in thermal power plant, the twisted strips structure is optimized. There are holes distributed in twisted strip uniformly. The holes diameter and interval are optimized through experimental research. The results show that when holes diameter is less than 6mm, holes can reduce the pressure drop increase at low flow velocity while the pressure drop with holes is greater than that without holes at high flow velocity. The holes diameter is 4~5mm when the pressure drop is the lowest. The pressure drop with holes is always larger than that without holes when holes diameter is more than 6mm. The pressure drop will increase as holes interval decreases at high flow velocity, while it will reduce at low flow velocity.


2012 ◽  
Vol 3 (6) ◽  
pp. 174-177 ◽  
Author(s):  
Sambhunath Dinda ◽  
◽  
Harekrishna Jana ◽  
Soma Bhattacharya ◽  
Keshab Chandra mondal

2012 ◽  
Vol 58 (4) ◽  
pp. 351-356
Author(s):  
Mincho B. Hadjiski ◽  
Lyubka A. Doukovska ◽  
Stefan L. Kojnov

Abstract Present paper considers nonlinear trend analysis for diagnostics and predictive maintenance. The subject is a device from Maritsa East 2 thermal power plant a mill fan. The choice of the given power plant is not occasional. This is the largest thermal power plant on the Balkan Peninsula. Mill fans are main part of the fuel preparation in the coal fired power plants. The possibility to predict eventual damages or wear out without switching off the device is significant for providing faultless and reliable work avoiding the losses caused by planned maintenance. This paper addresses the needs of the Maritsa East 2 Complex aiming to improve the ecological parameters of the electro energy production process.


2013 ◽  
Vol 12 (2) ◽  
pp. 337-342 ◽  
Author(s):  
Firuta Goga ◽  
Roxana Dudric ◽  
Calin Cormos ◽  
Florica Imre ◽  
Liliana Bizo ◽  
...  

Author(s):  
V. I. Minina ◽  
Yu. A. Nelyubova ◽  
Ya. A. Savchenko ◽  
A. A. Timofeeva ◽  
Ye. A. Astafieva ◽  
...  

Introduction. Coal heat power stations are characterized by severe hazardous eff ect of occupational environment on workers. Objective. To analyze chromosomal disorders in workers of thermal power plant working on coal from Kuznetsk coal fi eld (West Siberia). Materials and methods. Th e authors studied level and specter of chromosomal aberrations in blood lymphocytes of 185 workers of Kemerovo thermal power plant and 218 inhabitants of the same location, not working on industrial enterprises (Kemerovo, Russia). For every individual, average number of 200 metaphase plates of high quality was analyzed. Results. Findings are that the workers of thermal power plant have levels of chromosomal aberrations signifi cantly higher than those of reference group (3,01±0,13% vs. 1,45±0,08%; р<0,00001). With that, increased frequency is seen both for chromatid aberrations and for chromosomal ones — that indicates complex exposure to chemical and radiation factors. Conclusions. Th e results obtained necessitate elaboration of measures to decrease genotoxic hazards in the occupational environment.