scholarly journals A New Approach for Optimal Location and Sizing of Distributed Generation Using an Exact Solution Method

Author(s):  
Ken Kuroda ◽  
Tomiyasu Ichimura ◽  
Hideki Magori ◽  
Ryuichi Yokoyama
2017 ◽  
Vol 12 (1) ◽  
pp. 126-134
Author(s):  
A.M. Ilyasov

Based on the generalized Perkins-Kern-Nordgren model (PKN) for the development of a hyperbolic type vertical hydraulic fracture, an exact solution is obtained for the hydraulic fracture self-oscillations after terminating the fracturing fluid injection. These oscillations are excited by a rarefaction wave that occurs after the injection is stopped. The obtained solution was used to estimate the height, width and half-length of the hydraulic fracture at the time of stopping the hydraulic fracturing fluid injection based on the bottomhole pressure gauge data.


2021 ◽  
pp. 15-27
Author(s):  
Mamdouh Kamaleldin AHMED ◽  
◽  
Mohamed Hassan OSMAN ◽  
Nikolay V. KOROVKIN ◽  
◽  
...  

The penetration of renewable distributed generations (RDGs) such as wind and solar energy into conventional power systems provides many technical and environmental benefits. These benefits include enhancing power system reliability, providing a clean solution to rapidly increasing load demands, reducing power losses, and improving the voltage profile. However, installing these distributed generation (DG) units can cause negative effects if their size and location are not properly determined. Therefore, the optimal location and size of these distributed generations may be obtained to avoid these negative effects. Several conventional and artificial algorithms have been used to find the location and size of RDGs in power systems. Particle swarm optimization (PSO) is one of the most important and widely used techniques. In this paper, a new variant of particle swarm algorithm with nonlinear time varying acceleration coefficients (PSO-NTVAC) is proposed to determine the optimal location and size of multiple DG units for meshed and radial networks. The main objective is to minimize the total active power losses of the system, while satisfying several operating constraints. The proposed methodology was tested using IEEE 14-bus, 30-bus, 57-bus, 33-bus, and 69- bus systems with the change in the number of DG units from 1 to 4 DG units. The result proves that the proposed PSO-NTVAC is more efficient to solve the optimal multiple DGs allocation with minimum power loss and a high convergence rate.


Author(s):  
Gerhard G. G. Lueschen ◽  
Lawrence A. Bergman

Abstract A new approach to the exact solution is given for the free vibration of a periodic structure comprised of a multiplicity of identical linear distributed parameter substructures, closely coupled through identical linear springs. The method used is an extension of a classical result for periodic discrete systems.


Omega ◽  
2021 ◽  
pp. 102581
Author(s):  
Zhe Zhang ◽  
Xue Gong ◽  
Xiaoling Song ◽  
Yong Yin ◽  
Benjamin Lev ◽  
...  

2018 ◽  
Vol 10 (2) ◽  
pp. 65-79 ◽  
Author(s):  
Shabbir Uddin ◽  
Sandeep Chakravorty ◽  
Amitava Ray ◽  
Karma Sonam Sherpa

In this article, methodologies have been proposed for site selection of sub-station considering technical and non-technical constraints. Firstly, a systematic frame has been developed considering various factors that influence the optimal location of the sub-station. Various factors considered are evaluated using DEMATEL-QFD. An evaluation has been done between the outcome of the TOPSIS (Technique for order preference by similarity to ideal solution) method and the COPRAS (Compressed Proportional Assessment) method. Finally, Spearman rank co-relation co-efficients indicates the strength of association of both the methodologies. A case study is done using GIS to prove the justification of the methodologies to the applied area. The application of the methodologies will help the decision maker improve the plan, location and grid renovation of the distribution sub-stations.


Sign in / Sign up