C122 Study on the Task Air Conditioning System Using the System Separated the Latent Heat Load and Sensible Heat Load

2009 ◽  
Vol 2009 (0) ◽  
pp. 71-72
Author(s):  
Masato Sasaki ◽  
Takashi Yanai ◽  
Takashi Akimoto
2011 ◽  
Vol 347-353 ◽  
pp. 3036-3040
Author(s):  
Rui Ju ◽  
Qiu Na Cui

This paper is based on the BIN metrological data and calculates the cold and heat load of the building.According to the performance parameters of the WSHP, the energy consumption and cost of two typical schemes is calculated.Contrast the investment and cost of the SWHP and air conditioning system and discuss the applicability of commercial buildings. Result shows that WSHP costs less than traditional air conditioning in the present operation conditions. Energy-saving effect is remarkable.


2019 ◽  
pp. 9-14
Author(s):  
Євген Іванович Трушляков ◽  
Андрій Миколайович Радченко ◽  
Микола Іванович Радченко ◽  
Сергій Анатолійович Кантор ◽  
Веніамін Сергійович Ткаченко

One of the most attractive reserves of enhancing the energetic efficiency of air conditioning systems is to provide the operation of refrigeration compressors in nominal or close to nominal modes by choosing rational design cooling loads (cooling capacities) and their distribution according to a cooling load behaviour within the overall design (installed) cooling load band to match current changeable climatic conditions and provide close to maximum annual cooling capacity generation according to cooling duties. The direction of increasing the efficiency of outdoor air conditioning in combined central-local type systems by rationally distributing the heat load - cooling capacity of the central air conditioner into zones of variable heat load in accordance with current climatic conditions and its relatively stable value, i.e. cooling capacity required for further air cooling at the entrance to the indoor recirculation air conditioning system is justified. By comparing the values of the excessive production of cold and its deficit within every 3 days for a rational design heat load of the air conditioning system (cooling capacity of the installed refrigeration machine), which provides close to maximum annual production of cold, and the corresponding values of the excess and deficit of cooling capacity in accordance with current climatic conditions during July substantiated the feasibility of accumulating the excess of cooling capacity of a central air conditioner at low current loads and its use for covering cooling deficit at elevated heat loads through pre-cooling the outdoor air. It is developed a scheme of a combined central-local air conditioning system, which includes the subsystems for the outdoor air conditioning in a central air conditioner and the local indoor recirculated air conditioning.


Sign in / Sign up

Export Citation Format

Share Document