scholarly journals 3078) Separation of Sensible Heat Load and Latent Heat Load in Air Conditioning Analysis

Author(s):  
Toshio Maeda
2011 ◽  
Vol 403-408 ◽  
pp. 3235-3238 ◽  
Author(s):  
Jian Feng Qian

Urban sewage is a renewable energy source in the fields of heating and air conditioning engineering, and urban sewage source heat pump system plays an important role on energy-saving and environmental protection. According to the differences of the sewage emission coefficient and heat load of the building, it is not able to satisfy the user heating demand only on the limited temperature difference sensible heat on many situations, especially for the sewage rate of flow in small trunk canals. Therefore, a new heat system named urban sewage source heat pump system with freezing latent heat collection is proposed, in which the freezing latent heat is used as the heating source of the heat pump system at peak heat load in winter as well as the temperature difference sensible heat. According to the status, the system form is brought out and the operation modes of this heat pump system are stated, then the characteristics of the design and operating parameters are discussed.


2021 ◽  
pp. 014459872110052
Author(s):  
Yuechao Liu ◽  
Dong Guo ◽  
Min Zhou ◽  
Shanshan Wu ◽  
Dongmei Li

One optimization method of hourly heat load calculation model for heat storage air-conditioning heating system in different climate zones was proposed. A building model is initially built in six different climate zones. Subsequently, the hourly heat load and steady-state design heat load in different climate zones were analyzed. Simultaneously, the hourly heat load additional coefficient of the air-conditioning system with different heating modes on a typical day was compared. It can be found that steady-state design heat load on a typical day is mostly between the peak load and average load of the air-conditioning heating system. Simultaneously, results indicate that the hourly heat load additional coefficient in each climate zone can be fitted to different exponential functions. When the heat storage capacity of building components was changed, the maximum increase of the hourly heat load additional coefficient of the air-conditioning system with intermittent heating was 5%. Thus, the research of the optimal design of hourly heat load calculation method provides a relative reference for performance improvement of the heat storage air-conditioning heating system.


2013 ◽  
Vol 21 (02) ◽  
pp. 1350009 ◽  
Author(s):  
HWATAIK HAN ◽  
SANG-HOON NAM ◽  
GEON-SOO HAN

This study experimentally investigates the effect of internal condensation on the performance of a heat recovery ventilator. Experiments were performed using a plate-type sensible heat exchanger element that was designed for very humid and dusty environments such as chicken broiler houses. The results of these experiments show that the temperature efficiency considering condensation is always greater than that without considering latent heat. As outdoor temperature decreases or indoor relative humidity increases, temperature efficiency increases owing to an increase in the rate of condensation. The present polypropylene-based sensible heat exchanger element could be a solution for harsh environments because it can discharge condensate water by gravity and is resistant to moisture and other toxic gases.


2014 ◽  
Vol 11 (16) ◽  
pp. 4507-4519 ◽  
Author(s):  
T. S. El-Madany ◽  
H. F. Duarte ◽  
D. J. Durden ◽  
B. Paas ◽  
M. J. Deventer ◽  
...  

Abstract. Sodar (SOund Detection And Ranging), eddy-covariance, and tower profile measurements of wind speed and carbon dioxide were performed during 17 consecutive nights in complex terrain in northern Taiwan. The scope of the study was to identify the causes for intermittent turbulence events and to analyze their importance in nocturnal atmosphere–biosphere exchange as quantified with eddy-covariance measurements. If intermittency occurs frequently at a measurement site, then this process needs to be quantified in order to achieve reliable values for ecosystem characteristics such as net ecosystem exchange or net primary production. Fourteen events of intermittent turbulence were identified and classified into above-canopy drainage flows (ACDFs) and low-level jets (LLJs) according to the height of the wind speed maximum. Intermittent turbulence periods lasted between 30 and 110 min. Towards the end of LLJ or ACDF events, positive vertical wind velocities and, in some cases, upslope flows occurred, counteracting the general flow regime at nighttime. The observations suggest that the LLJs and ACDFs penetrate deep into the cold air pool in the valley, where they experience strong buoyancy due to density differences, resulting in either upslope flows or upward vertical winds. Turbulence was found to be stronger and better developed during LLJs and ACDFs, with eddy-covariance data presenting higher quality. This was particularly indicated by spectral analysis of the vertical wind velocity and the steady-state test for the time series of the vertical wind velocity in combination with the horizontal wind component, the temperature, and carbon dioxide. Significantly higher fluxes of sensible heat, latent heat, and shear stress occurred during these periods. During LLJs and ACDFs, fluxes of sensible heat, latent heat, and CO2 were mostly one-directional. For example, exclusively negative sensible heat fluxes occurred while intermittent turbulence was present. Latent heat fluxes were mostly positive during LLJs and ACDFs, with a median value of 34 W m−2, while outside these periods the median was 2 W m−2. In conclusion, intermittent turbulence periods exhibit a strong impact on nocturnal energy and mass fluxes.


Sign in / Sign up

Export Citation Format

Share Document