Inherent correlation between the total output cooling capacity and equipment sensible heat ratio of a direct expansion air conditioning system under variable-speed operation (XXG SMD SHR DX AC unit)

2010 ◽  
Vol 30 (13) ◽  
pp. 1601-1607 ◽  
Author(s):  
Xiangguo Xu ◽  
Liang Xia ◽  
Mingyin Chan ◽  
Shiming Deng
1999 ◽  
Author(s):  
Craig W. Wood ◽  
Josua P. Meyer

Abstract This study involves the experimental verification of a universal heat exchanger accumulator design procedure. A heat exchange accumulator was manufactured according to a mathematical model developed by the authors and installed into a small air conditioning system. Experimental results show that the addition of the heat exchanger accumulator results in a liquid overfeeding operation that replaces the previously utilized direct expansion operation. It provides an improved air conditioning system that has a 7.5% increase in coefficient of performance and a 4.4% increase in refrigerant mass flow rate. A pressure ratio reduction has a positive effect on the compressor performance and life span. Liquid overfeeding increases the cooling capacity of the system by 6.5%. When compared to direct expansion systems, this basic heat exchanger accumulator provides a reduction in cycling losses and power consumption, an increase in suction pressure and an improvement in isentropic compressor efficiency.


Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4757
Author(s):  
Yudong Xia ◽  
Shu Jiangzhou ◽  
Xuejun Zhang ◽  
Zhao Zhang

When using a certain type of Heating, Ventilation & Air Conditioning (HVAC) systems, it is primary to obtain their steady-state operating behaviors for achieving a better indoor thermal environment. This paper reports a development of a white-box-based dynamic model for a direct expansion (DX) air conditioning (A/C) system to predict its steady-state operating performance under variable speed operation. The established model consists of five sub-models, i.e., a compressor, an electronic expansion valve, an evaporator, a condenser and a conditioned space. Each sub-model was developed based on partial lumped parameter approach. Using the available data generated from an experimental DX A/C system, both transient and steady-state behaviors predictions agreed well with the experimental ones. With the help of the validated white-box model, the inherent steady-state operating performance expressed in terms of the relationship among total cooling capacity (TCC), equipment sensible heat ratio (E SHR) and coefficient of performance (COP) under various speed combinations of compressor and supply fan were further examined. The results show that a higher COP could be achieved when the DX A/C system was operated at a higher fan speed or a lower compressor speed for dealing with a larger required E SHR. This model could be helpful for A/C system design and controller development.


Author(s):  
Yilin Du ◽  
Jan Muehlbauer ◽  
Jiazhen Ling ◽  
Vikrant Aute ◽  
Yunho Hwang ◽  
...  

A rechargeable personal air-conditioning (RPAC) device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The conditioned air is discharged towards a single person through adjustable nozzle. The main focus of the current research was on the development of the cooling system. A 100 W cooling capacity prototype was designed, built, and tested. The cooling capacity of the vapor compression cycle measured was 165.6 W. The PCM was recharged in nearly 8 hours under thermosiphon mode. When this device is used in the controlled built environment, the thermostat setting can be increased so that building air conditioning energy can be saved by about 5–10%.