scholarly journals MHD Flow Behavior and Performance of Subsonic Non-equilibrium Disk MHD Generator Driven by Shock-tube Facility.

2001 ◽  
Vol 67 (658) ◽  
pp. 1416-1421 ◽  
Author(s):  
Yoshihiro NABARA ◽  
Yoshihiro OKUNO ◽  
Hiroyuki YAMASAKI
2006 ◽  
Vol 126 (9) ◽  
pp. 933-939 ◽  
Author(s):  
Alessandro Liberati ◽  
Tomoyuki Murakami ◽  
Yoshihiro Okuno ◽  
Hiroyuki Yamasaki

Author(s):  
Tomoyuki Murakami ◽  
Tetsuya Suekane ◽  
Kiyoshi Tsuji ◽  
Yoshihiro Okuno ◽  
Yasuo Hasegawa ◽  
...  

2022 ◽  
Vol 14 (1) ◽  
pp. 168781402110704
Author(s):  
Zhuang Dong ◽  
Jian Yang ◽  
Chendi Zhu ◽  
Dimitrios Chronopoulos ◽  
Tianyun Li

This study investigates the vibration power flow behavior and performance of inerter-based vibration isolators mounted on finite and infinite flexible beam structures. Two configurations of vibration isolators with spring, damper, and inerter as well as different rigidities of finite and infinite foundation structures are considered. Both the time-averaged power flow transmission and the force transmissibility are studied and used as indices to evaluate the isolation performance. Comparisons are made between the two proposed configurations of inerter-based isolators and the conventional spring-damper isolators to show potential performance benefits of including inerter for effective vibration isolation. It is shown that by configuring the inerter, spring, and damper in parallel in the isolator, anti-peaks are introduced in the time-averaged transmitted power and force transmissibility at specific frequencies such that the vibration transmission to the foundation can be greatly suppressed. When the inerter is connected in series with a spring-damper unit and then in-parallel with a spring, considerable improvement in vibration isolation can be achieved near the original peak frequency while maintaining good high-frequency isolation performance. The study provides better understanding of the effects of adding inerters to vibration isolators mounted on a flexible foundation, and benefits enhanced designs of inerter-based vibration suppression systems.


2015 ◽  
Vol 7 (3) ◽  
pp. 21-31 ◽  
Author(s):  
D. R. Kuiry ◽  
S. Bahadur

The steady flow behavior of a viscous, incompressible and electrically conducting fluid between two parallel infinite insulated horizontal porous plates with heat transfer is investigated along with the effect of an external uniform transverse magnetic field, the action of inflow normal to the plates, the pressure gradient on the flow and temperature. The fluid viscosity is supposed to vary exponentially with the temperature. A numerical solution for the governing equations for both the momentum transfer and energy transfer has been developed using the finite difference method. The velocity and temperature distribution graphs have been presented under the influence of different values of magnetic inclination, fluid pressure gradient, inflow acting perpendicularly on the plates, temperature dependent viscosity and the Hartmann number. In our study viscosity is shown to affect the velocity graph. The flow parameters such as viscosity, pressure and injection of fluid normal to the plate can cause reverse flow. For highly viscous fluid, reverse flow is observed. The effect of magnetic force helps to restrain this reverse flow.


Sign in / Sign up

Export Citation Format

Share Document