The effectiveness of laboratory tests to predict early postoperative periprosthetic infection after total knee arthroplasty

2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 177-184
Author(s):  
Mason E. Uvodich ◽  
Evan M. Dugdale ◽  
Douglas R. Osmon ◽  
Mark W. Pagnano ◽  
Daniel J. Berry ◽  
...  

Aims It remains difficult to diagnose early postoperative periprosthetic joint infection (PJI) following total knee arthroplasty (TKA). We aimed to validate the optimal cutoff values of ESR, CRP, and synovial fluid analysis for detecting early postoperative PJI in a large series of primary TKAs. Methods We retrospectively identified 27,066 primary TKAs performed between 2000 and 2019. Within 12 weeks, 169 patients (170 TKAs) had an aspiration. The patients were divided into two groups: those evaluated ≤ six weeks, or between six and 12 weeks postoperatively. The 2011 Musculoskeletal Infection Society (MSIS) criteria for PJI diagnosis in 22 TKAs. The mean follow-up was five years (two months to 17 years). The results were compared using medians and Mann-Whitney U tests and thresholds were analyzed using receiver operator characteristic curves. Results Within six weeks, the median CRP (101 mg/l vs 35 mg/l; p = 0.011), synovial WBCs (58,295 cells/μl vs 2,121 cells/μl; p ≤ 0.001), percentage of synovial neutrophils (91% vs 71% (p < 0.001), and absolute synovial neutrophil count (ANC) (50,748 cells/μl vs 1,386 cells/μl (p < 0.001) were significantly higher in infected TKAs. Between six and 12 weeks, the median CRP (85 mg/l vs 5 mg/l (p < 0.001)), ESR (33 mm/hr vs 14 mm/hr (p = 0.015)), synovial WBCs (62,247 cells/μl vs 620 cells/μl (p < 0.001)), percentage of synovial neutrophils (93% vs 54% (p < 0.001)), and ANC (55,911 cells/μl vs 326 cells/μl (p < 0.001)) were also significantly higher in infected TKAs. Optimal thresholds at ≤ six weeks were: CRP ≥ 82 mg/l (sensitivity 70%, specificity 77%), synovial WBCs ≥ 8,676 cells/μl (83%, 90%), percentage of synovial neutrophils ≥ 88% (67%, 78%), and ANC ≥ 8,346 cells/μl (83%, 91%). Between six and 12 weeks, thresholds were: CRP ≥ 34 mg/l (90%, 93%), synovial WBCs ≥ 1,983 cells/μl (80%, 85%), percentage of synovial neutrophils ≥ 76% (80%, 81%), and ANC ≥ 1,684 cells/μl (80%, 87%). Conclusion Early PJI after TKA should be suspected within six weeks if the CRP is ≥ 82 mg/l, synovial WBCs are ≥ 8,676 cells/μl, the percentage of synovial neutrophils is ≥ 88%, and/or the ANC is ≥ 8,346 cells/μl. Between six and 12 weeks, thresholds include a CRP of ≥ 34 mg/l, synovial WBC of ≥ 1,983 cells/μl, a percentage of synovial neutrophils of ≥ 76%, and/or an ANC of ≥ 1,684 cells/μl. Cite this article: Bone Joint J 2021;103-B(6 Supple A):177–184.

2019 ◽  
Vol 33 (07) ◽  
pp. 678-684 ◽  
Author(s):  
Fahad Hossain ◽  
Sujith Konan ◽  
Babar Kayani ◽  
Christina Kontoghiorghe ◽  
Toby Barrack ◽  
...  

AbstractThe use of valgus–varus constrained (VVC) implant designs in primary total knee arthroplasty (TKA) is considered in situations of severe deformities, bone loss, and inadequate soft tissue balance. It is not known whether the use of such prosthesis designs may predispose to reduced function owing to its constraining design. The components are usually implanted with diaphyseal stem extensions to dissipate the increased forces. The totally stabilized (TS) implant is a contemporary VVC design with metaphyseal fixation only. It has a conforming articulation with increased rotational freedom compared with conventional VVC designs. The aim of this study was to assess whether the use of the contemporary TS implant with its metaphyseally fixed components would be associated with inferior outcomes compared with conventional standard primary posterior stabilized (PS) implants. We reviewed 38 consecutive complex primary TKAs performed using the metaphyseally fixed TS implant and 76 matched patients receiving primary PS TKA, at a minimum follow-up of 24 months. The mean follow-up was 61.1 months (24–102). Only patients with osteoarthritis were included. Clinical outcome was assessed using range of motion (ROM) and Oxford knee score (OKS). Radiographic assessment was performed using the femorotibial angle (FTA) at 6 weeks followed by assessment of bone–implant interface lucencies at final follow-up. There were no major early postoperative complications. The mean postoperative ROM in the TS and PS groups were 114.1 and 112.0, respectively. There was no difference in the mean ROM and OKS between the two groups. The mean FTA for patients in both groups was within 3° of the expected. There was no evidence of progressive lucencies or implant migration at final follow-up. The metaphyseally fixed TS knee design achieves comparable short-term functional outcomes when compared with conventional PS designs in primary knee arthroplasty. Long-term follow-up studies are required to assess survivorship.


2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 32-37
Author(s):  
Santiago Restrepo ◽  
Eric B. Smith ◽  
William James Hozack

Aims Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years. Results At mid-term follow-up, the mean KOOS JR score improved significantly from 33.14 (0 t0 85, standard deviation (SD) 21.88) preoperatively to 84.12 (15.94 to 100, SD 20.51) postoperatively (p < 0.001), the mean VR/SF-12 scores improved significantly from physical health (PH), 31.21 (SD 5.32; 23.99 to 56.77) preoperatively to 42.62 (SD 10.72; 19.38 to 56.82) postoperatively (p < 0.001) and the mental health (MH), 38.15 (SD 8.17; 19.06 to 60.75) preoperatively to 55.09 (SD 9.64; 19.06 to 66.98) postoperatively (p < 0.001). A total of 11 revisions were undertaken, with an overall revision rate of 2.94%, including five for periprosthetic joint infection (1.34%), three for loosening (0.80%), two for instability (0.53%), and one for pain (0.27%). The overall survivorship was 97.06% and survivorship for aseptic loosening as the endpoint was 98.40%, with a 99.5% survivorship of the 3D-printed tibial component. Conclusion This 3D-printed cementless total knee system shows excellent survivorship at mid-term follow-up. This design and the ability to obtain cementless fixation offers promise for excellent long-term durability. Cite this article: Bone Joint J 2021;103-B(6 Supple A):32–37.


2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 51-58
Author(s):  
JaeWon Yang ◽  
Nathanael D. Heckmann ◽  
Cindy R. Nahhas ◽  
Michael B. Salzano ◽  
Gregory P. Ruzich ◽  
...  

Aims Recent total knee arthroplasty (TKA) designs have featured more anatomical morphologies and shorter tibial keels. However, several reports have raised concerns about the impact of these modifications on implant longevity. The aim of this study was to report the early performance of a modern, cemented TKA design. Methods All patients who received a primary, cemented TKA between 2012 and 2017 with a minimum two-year follow-up were included. The implant investigated features an asymmetrical tibial baseplate and shortened keel. Patient demographic details, Knee Society Scores (KSS), component alignment, and the presence of radiolucent lines at final follow-up were recorded. Kaplan-Meier analyses were performed to estimate survivorship. Results A total of 720 of 754 primary TKAs (95.5%) were included with a mean follow-up of 3.9 years (SD 1.3); 562 (78.1%) were cruciate-retaining and 158 (21.9%) were posterior-stabilized. A total of 11 (1.5%) required reoperation for periprosthetic joint infection and seven (1.0%) for aseptic tibial loosening (five cruciate-retaining, two posterior-stabilized). Loosening occurred at a mean of 3.3 years (0.9 to 6.5). There were no cases of loosening in the 33 patients who received a 14 mm × 30 mm tibial stem extension. All-cause survivorship was 96.6% at three years (95% confidence interval (CI) 95.3% to 98.0%) and 96.2% at five years (95% CI 94.8% to 97.7%). Survivorship with revision for aseptic loosening was 99.6% at three years (95% CI 99.1% to 100.0%) and 99.1% at five years (95% CI 98.4% to 99.9%). Tibial components were in significantly more varus in those with aseptic loosening (mean 3.4° (SD 3.7°) vs 1.3° (SD 2.0°); p = 0.015). There were no other differences in demographic, radiological, or surgical characteristics between revised and non-revised TKAs for aseptic loosening (p = 0.293 to 1.00). Mean KSS improved significantly from 57.3 (SD 9.5) preoperatively to 92.6 (SD 8.9) at the final follow-up (p < 0.001). Conclusion This is the largest series to date of this design of implant. At short-term follow-up, the rate of aseptic tibial loosening is not overly concerning. Further observation is required to determine if there will be an abnormal rate of loosening at mid- to long-term follow-up. Cite this article: Bone Joint J 2021;103-B(6 Supple A):51–58.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 807.3-807
Author(s):  
I. Moriyama

Background:No widely accepted view or criteria currently exist concerning whether or not patellar replacement (resurfacing) should accompany total knee arthroplasty for osteoarthritis of the knee.1)2)3)Objectives:We recently devised our own criteria for application of patellar replacement and performed selective patellar replacement in accordance with this set of criteria. The clinical outcome was analyzed.Methods:The study involved 1150 knees on which total knee arthroplasty was performed between 2005 and 2019 because of osteoarthritis of the knee. The mean age at operation was 73, and the mean postoperative follow-up period was 91 months. Our criteria for application of patellar replacement are given below. Criterion A pertains to evaluation of preoperative clinical symptoms related to the patellofemoral joint: (a) interview regarding presence/absence of pain around the patella, (b) cracking or pain heard or felt when standing up from a low chair, (c) pain when going upstairs/downstairs. Because it is difficult for individual patients to identify the origin of pain (patellofemoral joint or femorotibial joint), the examiner advised each patient about the location of the patellofemoral joint when checking for these symptoms. Criterion B pertains to intense narrowing or disappearance of the patellofemoral joint space on preoperative X-ray of the knee. Criterion C pertains to the intraoperatively assessed extent of patellar cartilage degeneration corresponding to class 4 of the Outerbridge classification. Patellar replacement was applied to cases satisfying at least one of these sets of criteria (A-a,-b,-c, B and C). Postoperatively, pain of the patellofemoral joint was evaluated again at the time of the last observation, using Criterion A-a,-b,-c.Results:Patellar replacement was applied to 110 knees in accordance with the criteria mentioned above. There were 82 knees satisfying at least one of the Criterion sets A-a,-b,-c, 39 knees satisfying Criterion B and 70 knees satisfying Criterion C. (Some knees satisfied 2 or 3 of Criteria A, B and C).When the pain originating from patellofemoral joint (Criterion A) was clinically assessed at the time of last observation, pain was not seen in any knee of the replacement group and the non-replacement group.Conclusion:Whether or not patellar replacement is needed should be determined on the basis of the symptoms or findings related to the patellofemoral joint, and we see no necessity of patellar replacement in cases free of such symptoms/findings. When surgery was performed in accordance with the criteria on patellar replacement as devised by us, the clinical outcome of the operated patellofemoral joint was favorable, although the follow-up period was not long. Although further follow-up is needed, the results obtained indicate that selective patellar replacement yields favorable outcome if applied to cases judged indicated with appropriate criteria.References:[1]The Effect of Surgeon Preference for Selective Patellar Resurfacing on Revision Risk in Total Knee Replacement: An Instrumental Variable Analysis of 136,116 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry.Vertullo CJ, Graves SE, Cuthbert AR, Lewis PL J Bone Joint Surg Am. 2019 Jul 17;101(14):1261-1270[2]Resurfaced versus Non-Resurfaced Patella in Total Knee Arthroplasty.Allen W1, Eichinger J, Friedman R. Indian J Orthop. 2018 Jul-Aug;52(4):393-398.[3]Is Selectively Not Resurfacing the Patella an Acceptable Practice in Primary Total Knee Arthroplasty?Maradit-Kremers H, Haque OJ, Kremers WK, Berry DJ, Lewallen DG, Trousdale RT, Sierra RJ. J Arthroplasty. 2017 Apr;32(4):1143-1147.Disclosure of Interests:None declared


2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 191-195
Author(s):  
Elizabeth B. Gausden ◽  
Matthew B. Shirley ◽  
Matthew P. Abdel ◽  
Rafael J. Sierra

Aims To describe the risk of periprosthetic joint infection (PJI) and reoperation in patients who have an acute, traumatic wound dehiscence following total knee arthroplasty (TKA). Methods From January 2002 to December 2018, 16,134 primary TKAs were performed at a single institution. A total of 26 patients (0.1%) had a traumatic wound dehiscence within the first 30 days. Mean age was 68 years (44 to 87), 38% (n = 10) were female, and mean BMI was 34 kg/m2 (23 to 48). Median time to dehiscence was 13 days (interquartile range (IQR) 4 to 15). The dehiscence resulted from a fall in 22 patients and sudden flexion after staple removal in four. The arthrotomy was also disrupted in 58% (n = 15), including a complete extensor mechanism disruption in four knees. An irrigation and debridement with component retention (IDCR) was performed within 48 hours in 19 of 26 knees and two-thirds were discharged on antibiotic therapy. The mean follow-up was six years (2 to 15). The association of wound dehiscence and the risk of developing a PJI was analyzed. Results Patients who sustained a traumatic wound dehiscence had a 6.5-fold increase in the risk of PJI (95% confidence interval (CI) 1.6 to 26.2; p = 0.008). With the small number of PJIs, no variables were found to be significant risk factors. However, there were no PJIs in any of the patients who were treated with IDCR and a course of antibiotics. Three knees required reoperation including one two-stage exchange for PJI, one repeat IDCR for PJI, and one revision for aseptic loosening of the tibial component. Conclusion Despite having a traumatic wound dehiscence, the risk of PJI was low, but much higher than experienced in all other TKAs during the same period. We recommend urgent IDCR and a course of postoperative antibiotics to decrease the risk of PJI. A traumatic wound dehiscence increases risk of PJI by 6.5-fold. Cite this article: Bone Joint J 2021;103-B(6 Supple A):191–195.


2019 ◽  
Vol 101-B (11) ◽  
pp. 1356-1361 ◽  
Author(s):  
Brian P. Chalmers ◽  
Kapil G. Mehrotra ◽  
Rafael J. Sierra ◽  
Mark W. Pagnano ◽  
Michael J. Taunton ◽  
...  

Aims Knee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results. Patients and Methods In total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2 (18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation. Results Survivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening. Conclusion Contemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356–1361.


2020 ◽  
pp. 2050020
Author(s):  
Xabier Foruria ◽  
Jesús Moreta ◽  
Carlos Jaramillo ◽  
Ane Anton ◽  
Isidoro Calvo ◽  
...  

Objective: Patient-specific positioning guides have been designed to improve precision in total knee arthroplasty. The aim of this study is to evaluate the medium-term clinical and radiological outcomes with magnetic resonance imaging-based patient-specific positioning guides. Material and methods: We retrospectively reviewed patients from two centers treated with total knee arthroplasty performed with patient-specific positioning guides. We enrolled patients operated on between January 2011 and December 2013, with a minimum follow-up of 5 years. Preoperative and postoperative hip knee angle (HKA) and position of each component in the coronal plane were assessed. Overall malalignment was defined as an outlier of more than [Formula: see text] from the neutral mechanical axis and specific malalignment as when any component showed more than [Formula: see text] of deviation. Clinical outcomes were evaluated using the Hospital for Special Surgery (HSS) knee Score. Results: This study included 68 patients with a mean age of 72 years. The mean postoperative alignment (HKA) was [Formula: see text] and 26.5% of patients showed coronal malalignment [Formula: see text]. Regarding femoral components, 19.1% showed specific malalignment [Formula: see text], while 11.7% of tibial components were classified as outliers. The mean HSS Knee Score at final follow up was 89.2. Patients whose implants were mechanically aligned did not obtain better functional outcomes ([Formula: see text]). Conclusion: In our series, the use of patient-specific positioning guides resulted in a range of mechanical malalignment, similar to conventional instrumentation results reported in the literature.


2020 ◽  
Vol 34 (01) ◽  
pp. 115-120
Author(s):  
Ali Utkan ◽  
Emrah Caliskan ◽  
Batuhan Gencer ◽  
Bulent Ozkurt

AbstractAlthough there are numerous studies about routine histopathological analysis during arthroplasty surgeries, most of them showed that new diagnoses have rarely been obtained as a result. The aim of this study was to evaluate the efficacy of routine pathological analyses of synovia resected during primary total knee arthroplasty in patients with osteoarthritis and its relevance in the treatment process. Of the 47 included patients who were followed up prospectively, 26 patients had clinical and histopathological concordant diagnoses and 21 patients had discrepant diagnoses. Oxford knee score and visual analogue score were performed for all the patients. Kallgren-Lawrence score was used for radiological analyses. The Mann-Whitney U test was used to examine the differences between the abnormally distributed variables. Mean age was 65.9 ± 4.3 years (range, 50–89 years) and mean follow-up time was 19 ± 7.8 months (range, 6–39 months). Grade IV gonarthrosis was found to be statistically lower in the discrepant group (p = 0.046). The mean preoperative Oxford knee score was 16.8 ± 2.3 (range, 2–23) and the mean postoperative Oxford knee score was 44.6 ± 1.8 (range, 27–48; p = 0.016). Postoperative Oxford knee scores and VAS were significantly increased in both the concordant and discrepant groups (p = 0.026 and p = 0.035, p = 0.019 and p = 0.039, respectively). Resection and histopathologic analyses of the hypertrophied and inflamed synovium encountered during primary arthroplasty procedure should be performed. This examination not only could provide crucial information that may influence the postoperative follow-up guidelines but also could help us to expand our knowledge and awareness of rare diseases that might yield osteoarthritis. The level of evidence for the study is level II.


2017 ◽  
Vol 30 (09) ◽  
pp. 894-897 ◽  
Author(s):  
Alun Yewlett ◽  
Ryan Trickett ◽  
Mark Forster ◽  
Adel Ghandour ◽  
Hannah Sellars

AbstractResection of Hoffa's fat pad during total knee arthroplasty is sometimes performed to improve access and view. Opponents of this technique argue that sacrificing the fat pad potentially compromises blood supply to the patellar tendon and it can subsequently shorten. Our objective was to identify any difference in the Insall-Salvati ratio of knees undergoing total knee arthroplasty between a cohort that had Hoffa's fat pad preserved and the one that had Hoffa's fat pad completely excised. The total knee arthroplasties by two surgeons at our institution were reviewed over a 3-year period. Surgeon A routinely preserves the fat pad and surgeon B routinely excises the fat pad. Radiographs preoperatively, immediately postoperatively, and at a minimum of 1-year follow up were analyzed for the Insall-Salvati ratio. A total of 161 knees were reviewed, 65 in the preserved group and 96 in the excised group with a mean age of 67 and 70 years, respectively. The mean preoperative Insall-Salvati ratio for the preserved group was 1.12 (±0.145) and excised group 1.16 (±0.168) (p = 0.094). The mean immediate postoperative Insall-Salvati ratio for the preserved group was 1.10 (±0.154) and for excised group 1.18 (±0.194). The difference in Insall-Salvati ratio from preoperative to the immediate postoperative period in the preserved group compared with the excised group demonstrated a significant difference (p = 0.010). However, the change of Insall-Salvati ratio at 1 year did not significantly differ between the groups (p = 0.059). There does not appear to be any difference in the Insall-Salvati ratios of both groups at 1 year's follow up; therefore, this study radiologically at least supports the use of either technique.


2020 ◽  
Author(s):  
Yang Li ◽  
Xinguang Wang ◽  
Hua Tian

Abstract Background: The reconstruction of massive bone defects is one of the main challenges in revision total knee arthroplasty (RTKA). Although several methods are available, each of them has its prominent shortcomings. The purpose of this study is to review the clinical outcomes of RTKA with massive proximal tibial bone defects using patient-customized three-dimensional (3D)-printed highly porous metaphyseal cones.Methods: We retrospectively reviewed seven RTKAs with Anderson Orthopaedic Research Institute (AORI) type III tibial defects using patient-customized 3D-printed highly porous metaphyseal cones, which have been performed at a single institution between 2016 and 2018. Results: The mean age at diagnosis of the patients was 68 years old (61-77). The mean length of follow-up was 25.3 months (19-36). At the latest follow-up, no aseptic loosening or prosthetic joint infection has been determined. The mean HSS increased from 49 (39-63) to 78 (70-83) (P<0.01); the mean WOMAC increased from 59 (46-73) to 26 (12-38) (P<0.01). All patients obtained the range of motion and mechanical alignment improvement postoperatively.Conclusion: The patient-customized 3D-printed metaphyseal cone could be a promising technique in addressing severe tibial defects in RTKA. Our study shows encouraging short-term clinical and radiological outcomes with no aseptic loosening, periprosthetic infection, or fracture. Nevertheless, further follow-up and the expansion of sample size are needed to demonstrate the advantage of this innovative technique fully.


Sign in / Sign up

Export Citation Format

Share Document