scholarly journals On the generalizability of same-day partial knee replacement surgery—A non-selective interventional study evaluating efficacy, patient satisfaction, and safety in a public hospital setting

PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0260816
Author(s):  
Magnus Tveit

Purpose Programs referred to as Fast-Track/Rapid Recovery/Enhanced Recovery After Surgery have proven both effective and safe in joint replacement surgery, to the degree where same-day discharge (SDD) has been attempted in carefully selected cases at specialized outpatient units. Therefore, the primary aim of this study was to evaluate a same-day surgery protocol regarding safety using the minor partial knee replacement (PKR) procedure by non-selectively recruiting patients at a public hospital for one consecutive year. Methods 33 unselected PKR cases were included in this open clinical trial. The inclusion/exclusion criteria were solely based on logistics, as all the procedures were medial PKRs, designated the first morning slots, and performed by one single-surgeon. Strict postoperative criteria based on vital parameters, urinary function, bleeding, and mobilization had to be met before discharge was considered. SDD rate, patient satisfaction, number of outpatient visits, adverse events and readmissions within 90 days were evaluated. A predetermined subgroup analysis was also conducted where patients <80 yrs. and with an American Society of Anesthesiologists (ASA) classification <III was compared with those aged ≥80 yrs. and/or ASA class ≥III. Results 29 of 33 (88%) successfully achieved SDD. In a univariate comparison, 100% of the patients <80 yrs. and ASA class <III achieved SDD, whereas a corresponding 43% applied for those aged ≥80 yrs. and/or ASA class ≥III (p = 0.001). A 93% overall satisfaction rate was reached. Only 8% extra outpatient visits were required, all occurring within the first 2 weeks (well in line with routine practice.) One plausible transient ischemic attack and one readmission caused by a penetrating trauma not affecting the knee were identified, both of which happened 10 weeks after surgery. No adverse events or readmissions occurred within the first 48 hours of surgery. Conclusion When following strict criteria for discharge, same-day partial knee replacement surgery may be both feasible and safe, even without preselection of patients.

Arthritis ◽  
2011 ◽  
Vol 2011 ◽  
pp. 1-6 ◽  
Author(s):  
N. Mahomed ◽  
Rajiv Gandhi ◽  
Lawrence Daltroy ◽  
J. N. Katz

Introduction. The objective of this study was to develop a short self-report questionnaire for evaluating patient satisfaction with the outcome of hip and knee replacement surgery. Methods. This scale consists of four items focusing on satisfaction with the extent of pain relief, improvement in ability to perform home or yard work, ability to perform recreational activities, and overall satisfaction with joint replacement. This instrument does not measure satisfaction with process of care. The responses are scored on a Likert scale, with the total score ranging from 25 to 100 per question. The instrument was tested on 1700 patients undergoing primary total hip and total knee replacement surgery, evaluated preoperatively, at 12 weeks, and one year postoperatively. Psychometric testing included internal consistency, measured with Cronbach's alpha, and convergent validity, measured by correlation with changes in measures of health status between the preoperative, 12-week, and one-year evaluations. Results. The internal consistency (reliability) of the scale, measured by the Cronbach's alpha, ranged from 0.86 to 0.92. The scale demonstrated substantial ceiling effects at 1 year. The scale scores correlated modestly with the absolute SF-36 PCS and WOMAC scores (ρ=0.56–0.63 and also with the WOMAC change scores (ρ=0.38–0.46) at both 12-week and 1-year followups. Conclusions. This instrument is valid and reliable for measuring patient satisfaction following primary hip and knee arthroplasty and could be further evaluated for use with other musculoskeletal interventions.


2014 ◽  
Vol 120 (4) ◽  
pp. 852-860 ◽  
Author(s):  
Cynthia So-Osman ◽  
Rob G. H. H. Nelissen ◽  
Ankie W. M. M. Koopman-van Gemert ◽  
Ewoud Kluyver ◽  
Ruud G. Pöll ◽  
...  

Abstract Background: Patient blood management is introduced as a new concept that involves the combined use of transfusion alternatives. In elective adult total hip- or knee-replacement surgery patients, the authors conducted a large randomized study on the integrated use of erythropoietin, cell saver, and/or postoperative drain reinfusion devices (DRAIN) to evaluate allogeneic erythrocyte use, while applying a restrictive transfusion threshold. Patients with a preoperative hemoglobin level greater than 13 g/dl were ineligible for erythropoietin and evaluated for the effect of autologous blood reinfusion. Methods: Patients were randomized between autologous reinfusion by cell saver or DRAIN or no blood salvage device. Primary outcomes were mean intra- and postoperative erythrocyte use and proportion of transfused patients (transfusion rate). Secondary outcome was cost-effectiveness. Results: In 1,759 evaluated total hip- and knee-replacement surgery patients, the mean erythrocyte use was 0.19 (SD, 0.9) erythrocyte units/patient in the autologous group (n = 1,061) and 0.22 (0.9) erythrocyte units/patient in the control group (n = 698) (P = 0.64). The transfusion rate was 7.7% in the autologous group compared with 8.3% in the control group (P = 0.19). No difference in erythrocyte use was found between cell saver and DRAIN groups. Costs were increased by €298 per patient (95% CI, 76 to 520). Conclusion: In patients with preoperative hemoglobin levels greater than 13 g/dl, autologous intra- and postoperative blood salvage devices were not effective as transfusion alternatives: use of these devices did not reduce erythrocyte use and increased costs.


2004 ◽  
Vol 51 (1) ◽  
pp. 110-116 ◽  
Author(s):  
Joe Feinglass ◽  
Hagay Amir ◽  
Patricia Taylor ◽  
Ithai Lurie ◽  
Larry M. Manheim ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document