Artificial Ligaments

Author(s):  
Andrew A. Amis
Keyword(s):  
1988 ◽  
Vol 10 (3) ◽  
pp. 221-227 ◽  
Author(s):  
F. Bonnel ◽  
J. -P. Micaleff

2000 ◽  
Vol 5 (5) ◽  
pp. 481-488 ◽  
Author(s):  
Sonia Lettry ◽  
Francesco Roccavilla ◽  
Bahaa B. Seedhom
Keyword(s):  

Author(s):  
Pan Ma ◽  
Tianwu Chen ◽  
Xiaopei Wu ◽  
Yuandi Hu ◽  
Kai Huang ◽  
...  

The insufficient bioactivity of polyethylene terephthalate (PET) artificial ligaments severely weakens the ligament-bone healing in anterior cruciate ligament (ACL) reconstruction, while osteogenic modification is a prevailing method to enhance osseointegration...


2018 ◽  
Vol 6 (12) ◽  
pp. 232596711881160 ◽  
Author(s):  
Zachary Paul Sinagra ◽  
Alan Kop ◽  
Moreica Pabbruwe ◽  
Jeremy Parry ◽  
Gavin Clark

Background: Artificial ligaments have been developed and used in the treatment of ligamentous injuries since the 1970s. The early generation of artificial ligaments showed promising short-term results but resulted in high rates of rupture and inflammatory reaction in the surrounding tissues. Purpose: To determine whether the use of Ligament Augmentation and Reconstruction System (LARS) ligaments is associated with the development of intra-articular foreign body reaction. Study Design: Case series; Level of evidence, 4. Methods: LARS ligaments were explanted from 15 patients under 6 consultant orthopaedic surgeons at 8 surgical centers. Of these, 14 explanted samples were sent for macroscopic and histological analysis, with the 1 remaining sample sent for scanning electron microscopy, to assess for inflammatory change as well as the degree of fibrous tissue ingrowth. Results: We observed a foreign body reaction in 10 of 14 explanted LARS ligaments. Seven samples demonstrated fibrous tissue ingrowth, with 5 producing only focal or incomplete ingrowth. The 2 samples with extensive fibrous coverage were completely free of any foreign body reaction, while all 5 remaining samples with only focal or partial fibrous ingrowth were associated with at least some degree of harmful immune response. Conclusion: The LARS ligament is still associated with a clinically significant degree of foreign body reaction despite the LARS Company’s efforts to reduce complications through improved design. The development and completion of fibrous tissue ingrowth may work to reduce the occurrence of a foreign body reaction.


2020 ◽  
Author(s):  
Chengyi Huang ◽  
Beiyu Wang ◽  
Hao Liu ◽  
Tingkui Wu ◽  
Kangkang Huang ◽  
...  

Abstract Introduction: The posterior ligamentous complex (PLC) offers restraints to deformation in a complex and interconnected manner. The stability and range of motion (ROM) of the posterior cervical spine is greatly restricted when the PLC is damaged, even without bone disruptions. We describe a novel surgical technique, its advantages, and the postoperative condition of the first patient to use artificial ligament in a reconstruction surgery of PLC injuries in patients without lower cervical vertebral fracture. This technique aimed to fully retain the mobility of the injured segment based on spinal stability and apply dynamic reconstruction in patients’ treatment.Method: We present a detailed description of the reconstruction surgery with artificial ligaments performed on C4-6 PLC injuries in a 27-year-old male presented with neck pain and restricted movement following a high fall injury accompanied by impaired movement of limbs. Results: Immediately postsurgery, the patient’s neck pain and quadriparesis had been improved. The spinal canal decompression and cervical spine sequence results were satisfactory, the facet joint face was in a good position, and the spinous process spacing returned to normal. After three months of rehabilitation, the patient reported improvement of symptoms and the physical and imaging examination showed a significant improvement in the patient’s condition. The patient’s neck mobility motor function had improved further.Conclusion: The present data demonstrate that the novel technique for reconstruction of PLC injury is feasible and safe. However, familiarity with cervical anatomy and adequate experience in lateral mass screws placement during surgery is crucial for this procedure. Therefore, a highly experienced cervical surgery team is recommended to perform the surgery.


2009 ◽  
Vol 9 (15) ◽  
pp. 2794-2800 ◽  
Author(s):  
Saber Marzougui ◽  
Saber Ben Abdessalem ◽  
Faouzi Sakli

2019 ◽  
Vol 7 (11_suppl6) ◽  
pp. 2325967119S0045
Author(s):  
Shiyi Chen ◽  
Tianwu Chen ◽  
Fang Wan

The dispute on artificial ligaments used for anterior cruciate ligament (ACL) reconstruction has been a long time issue. Admittedly, due to designing defects, materials deficient without creeping, viscoelasticity and biocompatibility, and incorrect surgical technique, early application of synthetic ligament in ACL reconstruction did not yield good outcomes. For a long time, a poor outcome occupied our consensus. Whilst the poignant lessons didn’t drive people to thoroughly figure out underlying reasons but amplified the fear of synthetics ligament in the ACL reconstruction. Recent 15 years, a new generation synthetic ligament, Ligament Advanced Reinforcement System (LARS) developed for ACL/PCL reconstruction has been widely used in China. There are at least 147 papers on LARS published in Chinese and over 47 SCI papers published in English. Consistently, a positive outcome has been concluded in most reports with an early return to sports and lower complication or failure rate. Cumulative failure rate from short- and mid-term follow-ups was only 2.6% according to Batty et al., which has been commended as “surprisingly impressive” by James H. Lubowitz of journal Arthroscopy. In China, LARS ligaments have been approved by CFDA since 2004 and been used for ACL reconstruction over 30,000 cases. Recently a national multi-centers clinical investigation has been done in long-term failure analysis of the ACLR with LARS, which has involved 20 Chinese clinical centers and 1146 cases with mean follow-up time of 87 months(7 years), organized by the Chinese Artificial Ligament Study Group (CALSG), with an acceptable outcome in failure rate of 4.5% and complication rate of 4.1%. The following factors were concluded as main failure reasons, 1)incorrect surgical technique in a non-isometric ACL reconstruction, 2)lack of the graft biocompatibility and rigid screw interface fixation, 3) non-suitable indicated patients’ selection and rehabilitation program. Compared with reported long-term failure rate in auto(10%)or in allografts(24%), the outcome of Synthetic ligament was more superior and acceptable results. Moreover, the functional evaluation and return to sports of the patients were also high satisfying, despite some complication, such as screw loose, remnant stimulation but very rear synovitis. Non-isometric tunnel position was the main failure reason which caused by surgeons tech. An ISOMETRIC surgical technique should be stressed especially in ACL reconstruction using synthetic, focused on surgeon education, instead of simply blaming the artificial graft. Based on the systemic review and our study, a modification of synthetic graft has been developed successfully in experiment, graft fixation, synthetics materials modified with Polyethylene Terephthalate (PET) which has facilitated the biocompatibility. Our clinical investigation has also focused on a near-isometric ACL reconstruction, which would decrease the graft tunnel motion and facilitate artificial graft successful. Non-isometric input will predispose the grafts easy failure because of over tension on the graft while joint moving. Carefully selected patients, proper surgical technique, and standard rehabilitation program will ensure artificial ligament successfully. We will keep devoting to innovate artificial ligaments, including tissue engineering, bio-mimics design, advanced fixation, hybrid graft designing and more precise Isometric surgical technique. Never forgetting our beginning mind, the artificial ligaments will open a new epoch in the future of ACL reconstruction.


2009 ◽  
Vol 12 (sup1) ◽  
pp. 31-32 ◽  
Author(s):  
D. Ait Aouit ◽  
M. Thourot ◽  
M. Manassero ◽  
V. Viateau ◽  
S. Guerard ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document