scholarly journals Assessment of ocular beta radiation dose distribution due to 106Ru/106Rh brachytherapy applicators using MCNPX Monte Carlo code

2014 ◽  
Vol 2 (3) ◽  
pp. 02038 ◽  
Author(s):  
Nilseia Barbosa ◽  
Luiz da Rosa ◽  
Artur Menezes ◽  
Juraci Reis ◽  
Alessandro Facure ◽  
...  
2010 ◽  
Vol 24 (05) ◽  
pp. 599-604
Author(s):  
ALI ASGHAR MOWLAWI ◽  
MAJED YAZDANI

The combination of 192 Ir seed with the Leipzig applicators is used in a considerable number of clinical trials for skin cancer treatment. As is known, the beneficial effects of ionizing radiation for tumor treatment depends on the dosimetry accuracy. Nowadays, dosimetry calculations are supported by the characteristics provided by the manufacturer, which have been obtained from measurements with an ionization chamber in a phantom. Despite their benefit, the experimental data involves errors related to the positioning, energy, and angular dependence of the detectors. Thus, in order to get a detailed and more accurate dosimetry, the Monte Carlo code MCNP4C2 — Monte Carlo Neutron Particle, 4C2 version — has been employed to analyze the dose distribution in depth and at the surface in the skin cancer treatment using Leipzig applicators. On the other hand, some different measurements have been taken to validate the method and compare results. The results for this material of phantom (the skin with 0.5 cm thick over infinite soft tissue) can be used in treatment planning systems and also for computation of model dependent parameters like anisotropy dose function.


2021 ◽  
Vol 15 ◽  
pp. 594
Author(s):  
Michel De Campos Vettorato ◽  
Jéssica Leite Fogaça ◽  
Sheila Canevese Rahal ◽  
Marco Antônio Rodrigues Fernandes

Betatherapy is a modality within brachytherapy that uses beta radiation applicators, which are used in the treatment of superficial injuries. With the advancement of therapeutic techniques, new clinical protocols in veterinary medicine will be established. In this sense, betatherapy appears as an important option for performing radiotherapy procedures and, consequently, further studies are necessary to define the clinical oncological protocols. Therefore, the aim of this study was to present a methodology for determining the dose distribution of beta radiation from strontium-90 (90Sr) applicators for use in intraoperative radiotherapy in veterinary medicine. Planar radiation dose distributions from three 90Sr applicators were analyzed using radiographic films, which were exposed to beams from sources at different exposure times. The optical density (O.D.) of the radiation field was verified with a digital densitometer. After scanning the films, using the ImageJ software, the brightness intensities (BI) for the radiation exposure fields were measured. The analysis of the radiation dose distribution of the betatherapy applicators, produced results similar to those already described in the literature. The use of the ImageJ software, as well as the O.D. obtained, helped in the analysis of dosimetric studies. The behavior of the dose-effect curves provided a better understanding of the homogeneity of the radiation field in the treatment plan and, therefore, the radiation dose distributions in the treatment fields indicate the use of these types of applicators in veterinary radiotherapy procedures.


2012 ◽  
Vol 81 (6) ◽  
pp. 609-617 ◽  
Author(s):  
Olivier Croce ◽  
Sabet Hachem ◽  
Eric Franchisseur ◽  
Serge Marcié ◽  
Jean-Pierre Gérard ◽  
...  

2015 ◽  
Vol 5 (4) ◽  
pp. 39-44
Author(s):  
Thanh Xuan Le ◽  
Cam Thu Nguyen Thi ◽  
Van Nghia Tran ◽  
Hong Loan Truong Thi ◽  
Thanh Nhon Vo

The dose distribution calculation is one of the major steps in radiotherapy. In this paper the Monte Carlo code MCNP5 has been applied for simulation 15MV photon beams emitted from linear accelerator in a case of lung cancer of the General Hospital of Kien Giang. The settings for beam directions, field sizes and isocenter position used in MCNP5 must be the same as those in treatment plan at the hospital to ensure the results from MCNP5 are accurate. We also built a program CODIM by using MATLAB­® programming software. This program was used to construct patient model from lung CT images obtained from cancer treatment cases at the General Hospital of Kien Giang and then MCNP5 code was used to simulate the delivered dose in the patient. The results from MCNP5 show that there is a difference of 5% in comparison with Prowess Panther program – a semi-empirical simulation program which is being used for treatment planning in the General Hospital of Kien Giang. The success of the work will help the planners to verify the patient dose distribution calculated from the treatment planning program being used at the hospital.


Sign in / Sign up

Export Citation Format

Share Document