Flexural Behavior of Hybrid Fiber-Reinforced Polymer/Concrete Beam/Slab Bridge Component

2004 ◽  
Vol 101 (2) ◽  
2021 ◽  
Vol 309 ◽  
pp. 01172
Author(s):  
G. Prashanth Naik ◽  
K Hemalatha ◽  
Srikanth Konik

This paper present the experimental result of flexural behavior of Hybrid Fiber Reinforced Polymer (HFRP) concrete beams reinforced with Glass Fiber Reinforced Polymer (GFRP) rebars and steel bars. This experiment is conducted with the aim of replacing steel reinforcement with GFRP rebars to reduce the risk of corrosion of steel in concrete structures. The data presented in this study is obtained by conducting flexural test experiment on four beams of HFRP beams with various PVA fibre dosage of 0%, 0.25% and 0.5% and one Pure FRP beam. Fly ash is added by 25% in the mix as a mineral admixture to control the shrinkage cracks. The test result showed that by addition of PVA fibre in HFRP concrete enhance the mechanical properties of beam like deflections, ductility, load carrying capacity and flexural capacity. The optimum dosage of PVA fibre is 0.25%. which improve flexural strength by 200% and 31.1% and ductility increased by 112.2% and 55.12% as compared with Pure FRP beam and HFRP beam without PVA fibre.


2020 ◽  
Vol 23 (7) ◽  
pp. 1487-1504 ◽  
Author(s):  
Bing Zhang ◽  
Jun-Liang Zhao ◽  
Tao Huang ◽  
Ning-Yuan Zhang ◽  
Yi-Jie Zhang ◽  
...  

Hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns are a novel form of hollow columns that combine two traditional construction materials (i.e. concrete and steel) with fiber-reinforced polymer composites. Hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns consist of an inner tube made of steel, an outer tube made of fiber-reinforced polymer, and a concrete layer between the two tubes. Existing studies, however, are focused on hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns with fibers of the fiber-reinforced polymer tube oriented in the hoop direction or close to the hoop direction. In order to investigate the effect of fiber angles (i.e. the fiber angle between the fiber orientation and the longitudinal axis of the fiber-reinforced polymer tube), monotonic axial compression tests were conducted on hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns with an fiber-reinforced polymer tube of ±45°, ±60°, or ±80° fiber angles. There were two types of steel tubes adopted for these hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns. The fiber-reinforced polymer tube thickness was also investigated as an important parameter. Experimental results showed that the confinement effect of the fiber-reinforced polymer tube increased with the increase of the absolute value of fiber angles, whereas the ultimate axial strain of hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns decreased with the increase of the absolute value of fiber angles. An existing stress–strain model, which was developed on the basis of hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns with an fiber-reinforced polymer tube of ±90° fiber angles, is verified using the test results of this study. For the compressive strength of the confined concrete in hybrid fiber-reinforced polymer–concrete–steel double-skin tubular columns, the existing model provides conservative predictions for specimens with a ±80° fiber-reinforced polymer tube, overestimated predictions for specimens with a ±60° fiber-reinforced polymer tube, and close predictions for specimens with a ±45° fiber-reinforced polymer tube.


Materials ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 3790 ◽  
Author(s):  
Wang ◽  
Petrů ◽  
Ai ◽  
Ou

The strengthening method of using hybrid fiber reinforced polymer is an effective way to increase the strengthening efficiency and lower the cost. This paper focuses on simulating the flexural behavior of reinforced concrete beam strengthened by prestressed C/GFRP (Carbon-Glass hybrid Fiber Reinforced Polymer) with different hybrid ratios and prestress levels. An elastoplastic damage constitution is used to simulate the mechanical behavior of concrete. A cohesive zone model under mixed mode is adopted to describe the debonding behavior of the FRP-concrete and concrete-steel interface. The results show good agreement with the experiment in the load-deflection curve, load-stress curve of steel, and HFRP. Furthermore, the failure mode of concrete and FRP debonding obtained from numerical simulation is the same as the test. Considering the improvement of the bending capacity, stiffness, and ductility of the strengthened beam in this paper, the best hybrid ratio of carbon to glass fiber is 1:1, and the suitable prestress level is between 30 and 50% of its ultimate strength.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Yousef Al Rjoub ◽  
Ala Obaidat ◽  
Ahmed Ashteyat ◽  
Khalid Alshboul

PurposeThis study aims to conduct an experimental study and finite element model (FEM) to investigate the flexural behavior of heat-damaged beams strengthened/repaired by hybrid fiber-reinforced polymers (HFRP).Design/methodology/approachTwo groups of beams of (150 × 250 × 1,200) mm were cast, strengthened and repaired using different configurations of HFRP and tested under four-point loadings. The first group was kept at room temperature, while the second group was exposed to a temperature of 400°C.FindingsIt was found that using multiple layers of carbon fiber-reinforced polymer (CFRP) and glass fiber-reinforced polymer (GFRP) enhanced the strength more than a single layer. Also, the order of two layers of FRP showed no effect on flexural behavior of beams. Using a three-layer scheme (attaching the GFRP first and followed by two layers of CFRP) exhibited increase in ultimate load more than the scheme attached by CFRP first. Furthermore, the scheme HGC (heated beam repaired with glass and carbon, in sequence) allowed to achieve residual flexural capacity of specimen exposed to 400°C. Typical flexural failure was observed in control and heat-damaged beams, whereas the strengthened/repaired beams failed by cover separation and FRP debonding, however, specimen repaired with two layers of GFRP failed by FRP rupture. The FEM results showed good agreement with experimental results.Originality/valueFew researchers have studied the effects of HFRP on strengthening and repair of heated, damaged reinforced concrete (RC) beams. This paper investigates, both experimentally and analytically, the performance of externally strengthened and repaired RC beams, in flexure, with different FRP configurations of CFRP and GFRP.