scholarly journals Evaluation of Cathodic Protection Criteria for Embedded Steel Reinforcement in concrete structures

2018 ◽  
Vol 7 (3.12) ◽  
pp. 333 ◽  
Author(s):  
Hirudayasamy Dolli ◽  
Andiappan Kavitha ◽  
Jeevarose .

This paper presents the results of performance of sacrificial protection in preventing the rebar corrosion in chloride contaminated and chloride free concrete. In this present study, the effectiveness of sacrificial protection of embedded steel rebars has been evaluated on chloride contaminated and chloride free concrete slabs using ribbon type Zinc anodes with ion conductive polymer backfill over a period of 250 days of exposure. The results showed that the ribbon type zinc sacrificial anodes with the navel electrochemical interface (Ion conductive polymer backfill) can confer effective corrosion protection of embedded steel in concrete on preventing corrosion initiation in chloride contaminated as well as chloride free concretes slabs. The cathodic protection criteria evaluated on concrete unit slab showed that 100-150mV is necessary in the atmospheric exposure and 160-200mV under alternate wetting & drying conditions. 

Materials ◽  
2021 ◽  
Vol 14 (4) ◽  
pp. 747
Author(s):  
Mariusz Jaśniok ◽  
Jacek Kołodziej ◽  
Krzysztof Gromysz

This article describes the comparative analysis of tests on bond strength of hot-dip galvanized and black steel to concrete with and without chlorides. The bond effect was evaluated with six research methods: strength, electrochemical (measurements of potential, EIS and LPR), optical, and 3D scanning. The tests were conducted within a long period of 18 months on 48 test elements reinforced with smooth rebars ϕ8 mm from steel grade S235JR+AR and ribbed rebars ϕ8 mm and ϕ16 mm from steel grade B500SP. The main strength tests on the reinforcement bond to concrete were used to compare forces pulling out galvanized and black steel rebars from concrete. This comparative analysis was performed after 28, 180, and 540 days from the preparation of the elements. The electrochemical tests were performed to evaluate corrosion of steel rebars in concrete, particularly in chloride contaminated concrete. The behaviour of concrete elements while pulling out the rebar was observed using the system of digital cameras during the optical tests. As regards 3D scanning of ribbed rebars ϕ8 mm and ϕ16 mm, this method allowed the detailed identification of their complex geometry in terms of determining the polarization area to evaluate the corrosion rate of reinforcement in concrete. The test results indicated that the presence of zinc coating on rebars had an impact on the parameters of anchorage. In the case of ribbed rebars of 16 mm in diameter, the maximum values of adhesive stress and bond stiffness were reduced over time when compared to black steel rebars. Moreover, it was noticed that the stiffness of rebar anchorage in chloride contaminated concrete was considerably higher than in concrete without chlorides.


2018 ◽  
Vol 173 ◽  
pp. 443-451 ◽  
Author(s):  
Han-Seung Lee ◽  
Hyun-Min Yang ◽  
Jitendra Kumar Singh ◽  
Shailesh Kumar Prasad ◽  
Bongyoung Yoo

2018 ◽  
Vol 51 (6) ◽  
Author(s):  
Hayder M. Oleiwi ◽  
Yu Wang ◽  
Michele Curioni ◽  
Xianyi Chen ◽  
Guowen Yao ◽  
...  

2010 ◽  
Vol 59 (5) ◽  
pp. 187-194 ◽  
Author(s):  
Toshiaki Kodama ◽  
Yoshio Shinoda ◽  
Kazuhiro Tanaka

CORROSION ◽  
2001 ◽  
Vol 57 (7) ◽  
pp. 591-597 ◽  
Author(s):  
S. Feliu ◽  
M. Morcillo ◽  
S. Feliu

2021 ◽  
pp. 116454
Author(s):  
Jitendra Kumar Singh ◽  
Hyun-Min Yang ◽  
Han-Seung Lee ◽  
Soumen Mandal ◽  
Fahid ASLAM ◽  
...  