Strategies of seismic damage mitigation for infilled RC frames: shake-table tests

2015 ◽  
Author(s):  
Hanhui Zhang
2017 ◽  
Vol 46 (14) ◽  
pp. 2419-2438 ◽  
Author(s):  
Hanhui Zhang ◽  
J.S. Kuang ◽  
Terry Y.P. Yuen

2013 ◽  
Vol 07 (03) ◽  
pp. 1350023 ◽  
Author(s):  
P. BENSON SHING ◽  
IOANNIS KOUTROMANOS ◽  
ANDREAS STAVRIDIS

This paper presents the findings of a research that focused on the seismic performance of masonry-infilled, nonductile, RC frames. This research has resulted in improved analytical methods and effective retrofit techniques to assess and enhance the performance of these structures. The methods were validated by a series of quasi-static tests conducted on one-story frame specimens as well as shake-table tests conducted on two 2/3-scale, three-story, two-bay, masonry-infilled, RC frames. This paper focuses on the observations from the shake-table tests and the further insight gained from a numerical study conducted with finite element models. The first shake-table test specimen had no retrofit measures, and the second had infill walls in the first and second stories strengthened with Engineered Cementitious Composite (ECC) and Fiber Reinforced Polymeric (FRP) overlays, respectively. The tests demonstrated the effectiveness of the retrofit measures. Finite element models that combine smeared and discrete cracks have been used in a numerical study to examine the benefits of the ECC retrofit and the influence of the capacity of the shear dowels that connect an ECC overlay to the RC beams on structural performance. It has been shown that these shear dowels play a critical role in enhancing both the strength and ductility of a retrofitted structure.


2021 ◽  
pp. 102886
Author(s):  
Jianyang Xue ◽  
Pengchun Hu ◽  
Fengliang Zhang ◽  
Yan Zhuge

2010 ◽  
Vol 132 (3) ◽  
Author(s):  
Izumi Nakamura ◽  
Akihito Otani ◽  
Masaki Shiratori

Pressurized piping systems used for an extended period may develop degradations such as wall thinning or cracks due to aging. It is important to estimate the effects of degradation on the dynamic behavior and to ascertain the failure modes and remaining strength of the piping systems with degradation through experiments and analyses to ensure the seismic safety of degraded piping systems under destructive seismic events. In order to investigate the influence of degradation on the dynamic behavior and failure modes of piping systems with local wall thinning, shake table tests using 3D piping system models were conducted. About 50% full circumferential wall thinning at elbows was considered in the test. Three types of models were used in the shake table tests. The difference of the models was the applied bending direction to the thinned-wall elbow. The bending direction considered in the tests was either of the in-plane bending, out-of-plane bending, or mixed bending of the in-plane and out-of-plane. These models were excited under the same input acceleration until failure occurred. Through these tests, the vibration characteristic and failure modes of the piping models with wall thinning under seismic load were obtained. The test results showed that the out-of-plane bending is not significant for a sound elbow, but should be considered for a thinned-wall elbow, because the life of the piping models with wall thinning subjected to out-of-plane bending may reduce significantly.


1996 ◽  
Vol 122 (3) ◽  
pp. 228-237 ◽  
Author(s):  
Armin B. Mehrabi ◽  
P. Benson Shing ◽  
Michael P. Schuller ◽  
James L. Noland

Sign in / Sign up

Export Citation Format

Share Document