An International Standard for holotranscobalamin (holoTC): international collaborative study to assign a holoTC value to the International Standard for vitamin B12 and serum folate

2016 ◽  
Vol 54 (9) ◽  
pp. 1467-1472 ◽  
Author(s):  
Susan J. Thorpe ◽  
Peter Rigsby ◽  
Graham Roberts ◽  
Anne Lee ◽  
Malcolm Hamilton ◽  
...  

AbstractBackground:Investigation of possible B12 and folate deficiencies requires measurement of these vitamins in serum. There is evidence that holotranscobalamin (holoTC), the active portion of B12 available to cells, is a more specific marker of early B12 deficiency than total B12. The availability of immunoassays for holoTC prompted an international collaborative study to assign a holoTC value to the World Health Organization (WHO) 1st International Standard (IS) for vitamin B12 and serum folate, 03/178.Methods:The IS, 03/178, and three serum samples with different holoTC levels were assayed by 12 laboratories in eight countries using manual and automated immunoassays for holoTC; one laboratory additionally performed an in-house assay. Fourteen sets of data were analysed.Results:Overall, the IS, 03/178, and the three serum samples demonstrated assay linearity and parallelism. An overall geometric mean (GM) holoTC value of 106.8 pmol/L was obtained for 03/178, with an inter-laboratory geometric coefficient of variation (GCV) of 10.5%. There was a reduction in inter-laboratory variability when the holoTC levels in the serum samples were determined relative to the IS with an assigned holoTC value rather than to the assays’ calibration. Accelerated degradation studies showed that 03/178 was sufficiently stable to serve as an IS for holoTC.Conclusions:The WHO Expert Committee on Biological Standardization endorsed the proposal to assign a holoTC value of 107 pmol/L to 03/178, corresponding to 0.107 pmol per ampoule, for use as the 1st IS for vitamin B12, serum folate, and holoTC.

2008 ◽  
Vol 16 (3) ◽  
pp. 303-311 ◽  
Author(s):  
Dorothy Xing ◽  
Carl Heinz Wirsing von König ◽  
Penny Newland ◽  
Marion Riffelmann ◽  
Bruce D. Meade ◽  
...  

ABSTRACT Enzyme-linked immunosorbent assay (ELISA) has been widely used to evaluate antibody responses to pertussis vaccination and infection. A common reference serum is essential for the standardization of these assays. However, no internationally recognized reference serum is available. At the request of the Expert Committee on Biological Standardization (ECBS) of the World Health Organization (WHO), a set of four candidate international standards has been prepared. These candidate materials have been assessed for suitability and compared to the widely used U.S. reference pertussis antiserum (human) lot 3, lot 4, and lot 5 by 22 laboratories from 15 countries in an international collaborative study. Laboratories measured immunoglobulin G (IgG) and IgA antibodies to pertussis toxin (PT), filamentous hemagglutinin (FHA), pertactin (PRN), and fimbriae (Fim2&3) using their established immunoassays. The results of this study showed each of the four candidates to be suitable as an international standard. With the agreement of the participants, a recommendation has been made to the ECBS that the candidate material coded 06/140 be established as the First International Standard for pertussis antiserum (human), with the following assigned international units (IU): IgG anti-PT, 335 IU/ampoule; IgA anti-PT, 65 IU/ampoule; IgG anti-FHA, 130 IU/ampoule; IgA anti-FHA, 65 IU/ampoule; IgG anti-PRN, 65 IU/ampoule; and IgA anti-PRN, 42 IU/ampoule. No formal units have been proposed for anti-Fim2&3 because most assays used a mixture of fimbrial antigens. In addition, the candidate material coded 06/142 has been proposed as a WHO working preparation for characterization of assay systems.


1997 ◽  
Vol 43 (9) ◽  
pp. 1582-1587 ◽  
Author(s):  
Susan J Thorpe ◽  
Dawn Walker ◽  
Paolo Arosio ◽  
Alan Heath ◽  
James D Cook ◽  
...  

Abstract A recombinant L ferritin preparation, lyophilized in ampoules and designated 94/572, was evaluated by 18 laboratories in 9 countries for its suitability as an International Standard (IS). The preparation was assayed in a wide range of in-house and commercial immunoassays against the 2nd IS for ferritin (of spleen origin; 80/578). The immunological reactivity of the recombinant material was similar to that of the 2nd IS for ferritin in the majority of assays and demonstrated adequate stability in accelerated degradation studies. On the basis of the results presented here, the WHO Expert Committee on Biological Standardization established 94/572 as the 3rd IS for ferritin, recombinant.


1985 ◽  
Vol 104 (3) ◽  
pp. 367-379 ◽  
Author(s):  
R. E. Gaines Das ◽  
A. F. Bristow

ABSTRACT Four batches of ampouled materials in ampoules coded 80/558, 81/502, 81/565 and 81/615 were evaluated by 22 laboratories in nine countries in an international collaborative study for their suitability to serve as a replacement for the First International Reference Preparation (IRP) of TSH, Human, for Immunoassay. The ampouled preparations were calibrated by immunoassay and bioassay. The preparation coded 80/558 had satisfactory stability and contained acceptably low levels of contamination with FSH and LH. Estimates of the immunoreactive TSH content of a set of specimens of serum in terms of 80/558 showed agreement in ranking order and no increase in variability compared with estimates made by assay against the First IRP. On the basis of these results, with the agreement of the participants in the study, and with the authorization of the Expert Committee on Biological Standardization of the World Health Organization, the preparation coded 80/558 was established in 1983 as the Second International Reference Preparation of TSH, Human, for Immunoassay, with a defined potency of 37 mi.u./ampoule. Preparations coded 81/502, 81/565 and 81/615 were found suitable to serve as working standards. J. Endocr. (1985) 104, 367–379


Author(s):  
Bernard Fox ◽  
Graham Roberts ◽  
Eleanor Atkinson ◽  
Peter Rigsby ◽  
Christina Ball

Abstract Objectives To evaluate and calibrate two candidate preparations for the 4th International Standard for Ferritin (Human, Recombinant) (codes: 19/118 and 19/162) against the 3rd International Standard for Ferritin (Human, Recombinant) (code: 94/572), and three serum commutability samples in an international collaborative study involving 12 laboratories in nine countries. Methods Eleven of the 12 participating laboratories performed Ferritin quantitation using automated assay platforms and one laboratory used a manual ELISA kit. Results There was better overall agreement between all laboratories and between assay methods for the potency of preparation 19/118 than for preparation 19/162. The overall geometric mean potency (from all methods) of the candidate 4th International Standard, 19/118, was 10.5 µg/ampoule, with inter-laboratory variability, expressed as % geometric coefficient of variation (GCV), of 4.7%. Accelerated stability studies have predicted both 19/118 and 19/162 to be very stable for long term storage at −20 °C. Conclusions The candidate 4th International Standard for Ferritin (Human, Recombinant) (19/118) has been shown to be immunologically similar to the 3rd International Standard for Ferritin (Human, Recombinant) (94/572). It was recommended to and accepted by the WHO Expert Committee on Biological Standardization that 19/118 be established as the 4th International Standard for Ferritin (Human, Recombinant) with an assigned potency of 10.5 µg/ampoule and expanded uncertainty limits 10.2–10.8 µg/ampoule (95% confidence; k=2.23).


1983 ◽  
Vol 50 (03) ◽  
pp. 645-649 ◽  
Author(s):  
P J Gaffney ◽  
M V Mussett

SummaryAn international collaborative study involving seven laboratories was undertaken to assess the suitability of a freeze- dried preparation of human plasmin to replace the current International Reference Preparation (IRP) for plasmin. Chromogenic and fibrinolytic assays were used by all participating laboratories to assess the potencies of the Proposed International Reference Preparation (PIRP) and two other freeze-dried plasmins, one of human and one of porcine originThe data suggest that the PIRP is a more suitable standard for plasmin than the IRP in that the former binds to fibrin whereas only 50% of the latter binds. The PIRP compared well to other plasmin preparations and the potency assays were independent of the assay procedure and substrate used. Degradation studies indicated that the PIRP was far more stable than the glycerol solution of the IRP, surviving for 12 months at 37° C with no significant loss in either amidolytic or fibrinolytic activity. The International Committee for Thrombosis and Haemostasis (Bergamo, 1982) has recommended the use of this material as a standard and it has been established by the Expert Committee on Biological Standardization of the World Health Organization as the second International Reference Preparation for Plasmin with a defined potency of 10 International Units of Plasmin per ampoule.