Intelligent Power Swing Detection Scheme to Prevent False Relay Tripping Using S-Transform

2014 ◽  
Vol 15 (3) ◽  
pp. 291-298 ◽  
Author(s):  
Nor Z. Mohamad ◽  
Ahmad F. Abidin ◽  
Ismail Musirin

Abstract Distance relay design is equipped with out-of-step tripping scheme to ensure correct distance relay operation during power swing. The out-of-step condition is a consequence result from unstable power swing. It requires proper detection of power swing to initiate a tripping signal followed by separation of unstable part from the entire power system. The distinguishing process of unstable swing from stable swing poses a challenging task. This paper presents an intelligent approach to detect power swing based on S-Transform signal processing tool. The proposed scheme is based on the use of S-Transform feature of active power at the distance relay measurement point. It is demonstrated that the proposed scheme is able to detect and discriminate the unstable swing from stable swing occurring in the system. To ascertain validity of the proposed scheme, simulations were carried out with the IEEE 39 bus system and its performance has been compared with the wavelet transform–based power swing detection scheme.

Author(s):  
Nor Zulaily Mohamad ◽  
Ahmad Farid Abidin ◽  
Ismail Musirin

<span>Distance relay is prone to mal-operate during power swing, thus most of modern distance relay design is equipped with power swing blocking scheme to block the operation during power swing and reset the blocking operation whenever a fault occurs during power swing. However, the detection of fault during power swing especially for high resistance fault possess a challenging task, therefore it may cause the unblocking function to vulnerable to operate. This paper presents the development of a detection scheme for detecting fault during power swing in test system interconnected with Distributed Generation (DG). In this study, the detection scheme is proposed based on S-Transform analysis on the distance relay input voltage signal. It is demonstrated that the proposed S-Transform detection based scheme can effectively detect various type of fault during power swing includes high resistance fault, as well as able to operate correctly even with the presence of DG in the test system.</span>


2012 ◽  
Vol 95 (3) ◽  
pp. 751-756 ◽  
Author(s):  
Erdal Dinç ◽  
Eda Büker

Abstract A new application of continuous wavelet transform (CWT) to overlapping peaks in a chromatogram was developed for the quantitative analysis of amiloride hydrochloride (AML) and hydrochlorothiazide (HCT) in tablets. Chromatographic analysis was done by using an ACQUITY ultra-performance LC (UPLC) BEH C18 column (50 × 2.1 mm id, 1.7 μm particle size) and a mobile phase consisting of methanol–0.1 M acetic acid (21 + 79, v/v) at a constant flow rate of 0.3 mL/min with diode array detection at 274 nm. The overlapping chromatographic peaks of the calibration set consisting of AML and HCT mixtures were recorded rapidly by using an ACQUITY UPLC H-Class system. The overlapping UPLC data vectors of AML and HCT drugs and their samples were processed by CWT signal processing methods. The calibration graphs for AML and HCT were computed from the relationship between concentration and areas of chromatographic CWT peaks. The applicability and validity of the improved UPLC-CWT approaches were confirmed by recovery studies and the standard addition technique. The proposed UPLC-CWT methods were applied to the determination of AML and HCT in tablets. The experimental results indicated that the suggested UPLC-CWT signal processing provides accurate and precise results for industrial QC and quantitative evaluation of AML-HCT tablets.


Author(s):  
Mayank Srivastava ◽  
Jamshed M Siddiqui ◽  
Mohammad Athar Ali

The rapid development of image editing software has resulted in widespread unauthorized duplication of original images. This has given rise to the need to develop robust image hashing technique which can easily identify duplicate copies of the original images apart from differentiating it from different images. In this paper, we have proposed an image hashing technique based on discrete wavelet transform and Hough transform, which is robust to large number of image processing attacks including shifting and shearing. The input image is initially pre-processed to remove any kind of minor effects. Discrete wavelet transform is then applied to the pre-processed image to produce different wavelet coefficients from which different edges are detected by using a canny edge detector. Hough transform is finally applied to the edge-detected image to generate an image hash which is used for image identification. Different experiments were conducted to show that the proposed hashing technique has better robustness and discrimination performance as compared to the state-of-the-art techniques. Normalized average mean value difference is also calculated to show the performance of the proposed technique towards various image processing attacks. The proposed copy detection scheme can perform copy detection over large databases and can be considered to be a prototype for developing online real-time copy detection system.   


2019 ◽  
Vol 2 (1) ◽  
Author(s):  
Mohd Fairusham Ghazali ◽  
Abdul Kadir Samta

This research project is focusing on the leakage detection in the pipelines using wavelet and cepstrum analysis. To fully complete this research project, experimental and analysis by using signal processing are required. This research project proposed a technique which is a transient method. The basic principle is the fact that water spouting out of a leak in a pressurized pipe generates a signal, and this signal contains information to whether a leak exists and where it is located. The present transient methods for finding leaks are mainly based upon correlation analysis, where one sensing device is installed at each side of a leak. This method is hard to operate because it needs many operators to operate it due to equipment in different place. This research project proposed a wavelet transform method to detect leakage in the pipeline system. The experimental results show appears  to improve the ability of the method to identify features in the signal.