Identification of the best topology of delta configured three phase induction generator for distributed generation through experimental investigations

Author(s):  
Vanka Bala Murali Krishna ◽  
Sandeep Vuddanti

Abstract Research on Self –excited induction generator (SEIG) brings a lot of attentions in the last three decades as a promising solution in distributed generation systems with low cost investment. There are two important fixations to attend in the operation of SEIG based systems, a) excitation and b) voltage regulation. Many procedures are reported regarding selection of excitation capacitance in the literature, based on state-state analysis, dynamic modeling, empirical formulas and machine parameters which involve various levels of complexity in findings. Moreover, the voltage regulation is the main challenge in implementation of SEIG based isolated systems. To address this problem, many power electronic-based schemes are proposed in the literature and but these solutions have few demerits importantly that additional cost of equipment and troubles due to failure of protection schemes. In particular, the installation of SEIG takes place at small scale in kW range in remote/rural communities which should not face such shortcomings. Further in case of off-grid systems, the maximum loading is fixed based on connected rating of the generator. This paper presents the various methods to find excitation capacitance and illustrates an experimental investigation on different possible reactive power compensation methods of delta connected SEIG and aimed to identify a simple method for terminal voltage control without power electronics. In this experimental work, the prime-mover of the generator is a constant speed turbine, which is the emulation of a micro/pico hydro turbine. From the results, it is found that a simple delta connected excitation and delta configured reactive power compensation limits voltage regulation within ±6% while maintaining the frequency of ±1%, which make feasible of the operation successfully in remote electrification systems.

Vestnik MEI ◽  
2021 ◽  
Vol 3 (3) ◽  
pp. 11-18
Author(s):  
Nailia Sh. Chemborisova ◽  
◽  
Ivan D. Chernenkov ◽  

The problem of selecting the electric power system control nodes is studied. By performing control of these modes, matters concerned with providing reliable power supply of the required quality to consumers can be settled in the most efficient manner. As an example, a fragment of the electric power system mathematical model used in the Finist mode-setting simulator for a power system dispatch control center operator is considered, which represents a highly branched electrical network consisting of eleven 110 kV nodes, three 220 kV nodes connected with the system, and two generator nodes. A new procedure for selecting the control nodes is proposed, which takes into account a combination of different indicators having different measurement units, dimensions and scales is proposed. These indicators characterize the following properties of power system nodes: the reactive power fraction absorbed at a node, the sensitivity of voltage to reactive load variations, the number of connected power lines, and statistical indicators characterizing the change of voltage at the nodes and reactive power flows for different options of installing the reactive power compensation devices. For combined use of these indicators, they were ranked according to the efficiency of installing reactive power compensation devices in the system. For each indicator, a scale of five ranks (intervals) is set, which determine the preferences (qualitative judgments) of the researcher in evaluating the reactive power compensation devices installation efficiency at the system nodes. The highest rank (5) corresponds to the maximum efficiency, and the lowest rank (1) corresponds to the minimum efficiency. To calculate the individual (integral) priority indicator of installing reactive power compensation devices, the ranks of indicators are added together, and their sum is divided by the product of the number of ranks by the number of the used indicators (features). Based on the calculation results, the rating (location) of each node is determined, and the nodes for installing the reactive power compensation devices are selected according to their effect on ensuring the electric power system operation reliability, active power losses in the network, and voltage regulation. Thus, a new procedure is presented for determining the integral indicators for comprehensively estimating the properties of complex electric power system nodes and selecting the controlled nodes using a system of various indicators. These indicators characterize the studied nodes in terms of the efficiency of installing reactive power compensation devices to reduce active power losses in the network, voltage regulation, and ensuring the electric power system operational reliability. The validity of the results obtained in the study is confirmed by their comparison with the indicators of the balance-conductivity method, which has proven itself in solving problems connected with determining the nodes for controlling electric power system operation modes.


Author(s):  
Pallavi Thakkur ◽  
Smita Shandilya

Self-Excited Induction Generator (SEIG) offers many advantages such as low cost, simplicity, robust construction, self-protection against faults and maintenance free in today's renewable energy industry. However, the SEIG demands an external supply of reactive power to maintain the constant terminal voltage under the varying loading conditions, which limits the application of SEIG as a standalone power generator. The regulation of speed and voltage does not result in a satisfactory improvement although several studies have been emphasized on this topic in the past. To improve the performance of the SEIG system in isolated areas and to regulate the terminal voltage STATic COMpensator (STATCOM) has been modelled and developed in this dissertation. The STATCOM consists of AC inductors, a DC bus capacitor and solid-state self-commutating devices. The ratings of these components are quite important for designing and controlling of STATCOM to maintain the constant terminal voltage. The proposed generating system is modelled and simulated in MATLAB along with Simulink and sim power system block set toolboxes. The simulated results are presented to demonstrate the capability of an isolated power generating system for feeding three-phase resistive loads.


Author(s):  
Allie E. Auld ◽  
Jack Brouwer ◽  
Scott Samuelsen ◽  
Keyue M. Smedley

The challenges associated with incorporating a large amount of distributed generation (DG), including fuel cells, into a radial distribution feeder are examined using a Matlab/Simulink™ model. Two generic distribution feeder models are used to investigate possible scenarios where voltage problems may occur. Modern inverter topologies make ancillary features, such as on-demand reactive power generation/consumption economical to include, which expands the design space across which DG can function in the distribution system. The simulation platform enables testing of the following local control goals: DG connected with unity power factor, DG and load connected with unity power factor, DG connected with local voltage regulation (LVR), and DG connected with real power curtailment. Both the LVR and curtailment strategies can regulate the voltage of the simplest circuit case, but the circuit utilizing a substation with load drop compensation has no universal solution. Even DG with a penetration level around 10% of rated circuit power can cause overvoltage problems with load drop compensation. This implies that some degree of communication will be needed to reliably install a large amount of DG on a distribution circuit.


2020 ◽  
Vol 8 (5) ◽  
pp. 4656-4660

The current energy demand scenario leads to tremendous increase in the renewable energy sector, but the integration of these renewable causes various stability issues of the system. Increasing share Wind energy has several shortages due to its energy harnessed from the wind. These shortages can be improved by compensating reactive power into the wind plant. The wind farm consist of fixed speed squirrel cage Induction generator absorbs reactive power from the grid for stable operation and it can be injected using reactive power compensator. In this context, the main aim of the research is to find the minimum reactive power compensation required for stable operation for different rating of Type-1 WTG in grid connected mode. In this paper, a detailed model of constant speed Squirrel Cage Induction Generator is carried out in MATLAB/SIMULINK-2017a to analyze the need of reactive power compensation to maintain voltage and frequency stability of the system during normal condition. The work also focuses on to investigate the impact of induction generator inertia level on compensation level. The modified IEEE 5-bus radial distribution system is used to conduct these investigations and the simulation results clearly show that: (1) The necessity and minimum additional reactive power support to the wind farm to improve and maintain stability of the system; (2) the inertia level of wind farm and reactive power compensator level both are independent each other.


2017 ◽  
Vol 5 (2) ◽  
pp. 35 ◽  
Author(s):  
RAFI K. MAHAMMAD ◽  
FATIMA ANAM ◽  
PRASAD P.V.N ◽  
◽  
◽  
...  

Sign in / Sign up

Export Citation Format

Share Document