scholarly journals Effect Of Selected Factors On The Safety Integrity Level (SIL)

2015 ◽  
Vol 35 (1) ◽  
pp. 85-98
Author(s):  
Młynarski Stanisław ◽  
Pilch Robert ◽  
Kaczor Grzegorz ◽  
Smolnik Maksymilian ◽  
Szkoda Maciej ◽  
...  

Abstract The presented paper concerns the functional safety problems of technical systems. The characteristics of safety assessment, described in IEC 61508 standard are an introduction to the problems associated with the methodology of the calculation of Safety Integrity Levels (SIL). The parameters obtained from reliability indicators, were calculated for the purpose of assessing the impact of repair time for the elements of a given system on the SIL. The calculated values of failure rate and the probability of dangerous failure show the sensitivity of the system at different time to repair values for various reliability-wise configurations. The indicators characterizing the safety level, calculated of the system with no repair time are the basis for demonstrating the influence of repair on the safety integrity level.

Author(s):  
Shinji Inoue ◽  
Takaji Fujiwara ◽  
Shigeru Yamada

Safety integrity level (SIL)-based functional safety assessment is widely required in designing safety functions and checking their validity of electrical/electronic/programmable electronic (E/E/PE) safety-related systems after being issued IEC 61508 in 2010. For the hardware of E/E/PE safety-related systems, quantitative functional safety assessment based on target failure measures is needed for deciding or allocating the level of SIL. On the other hand, IEC 61508 does not provide any quantitative safety assessment method for allocating SIL for the software of E/E/PE safety-related systems because the software failure is treated as a systematic failure in IEC 61508. We discuss the needfulness of quantitative safety assessment for software of E/E/PE safety-related systems and propose mathematical fundamentals for conducting quantitative SIL-based safety assessment for the software of E/E/PE safety-related systems by applying the notion of software reliability modeling and assessment technologies. We show numerical examples for explaining how to use our approaches.


Energies ◽  
2021 ◽  
Vol 14 (23) ◽  
pp. 7872
Author(s):  
Shiguang Li ◽  
Xiaojie Wu

Modern explosion protection equipment, protected by traditional explosion protection technology (as defined by the international electrotechnical commission (IEC) publication IEC60079-ff series standards) and electrical/electronic/programmable electronic (E/E/PE) safety-related systems, is becoming ever more complex in coal mine development and petrochemical industry; thus, the possibility of failures in their operation is also growing. It is well-known that E/E/PE safety-related systems can be used to actively control dangerous sources, with real and expected levels of reliability, if they have been qualified according to the IEC61508-ff series standards. To uniformly evaluate the safety integrity level (SIL) of the explosion protection function of traditional explosion protection technology and E/E/PE safety-related system technology, this study analyzed the ability of these types of protection to remove the ignition risk residual, evaluating the failure rates of safety devices. The key objective of this paper is the presentation of a new equipment protection level (EPL) assessment method for explosion protection equipment based on a functional safety assessment. The method is applied to a variable frequency drive (VFD) system, and the results show that the EPL of the explosion protection equipment evaluated by this method is consistent with the EPL corresponding to the traditional explosion protection type of the IEC60079-ff series standard. Meanwhile, the flexible configuration of explosion protection safety devices and E/E/PE safety-related systems enables explosion protection equipment of different EPL levels to be designed.


2008 ◽  
Vol 6 (3) ◽  
pp. 25-40
Author(s):  
Barnert Tomasz ◽  
Kosmowski Kazimierz ◽  
Śliwiński Marcin

Security Aspects in Verification of the Safety Integrity Level of Distributed Control and Protection SystemsThe article addresses some important issues of the functional safety analysis, namely the safety integrity level (SIL) verification of distributed control and protection systems with regard to security aspects. A quantitative method for SIL (IEC 61508) verification, based on so called differential factors, is presented. Taking into account SIL and the evaluation assurance level (EAL), which concerns the level of information security within entire system, two parametrical criterion function is defined for the SIL verification.


Author(s):  
Shinji Inoue ◽  
Takaji Fujiwara ◽  
Shigeru Yamada

Quantitative and analytical safety assessment methods of E/E/PE safety-related software systems based on the SIL defined by IEC 61508 have been proposed. IEC 61508 does not provide us with quantitative and analytical methods for safety assessment of the software. Our methods give us quantitative information on safety measures for deciding the safety integrity level and testing time duration for achieving certain safety integrity level of E/E/PE software, respectively. Our stochastic modeling approaches are based on software reliability modeling and software reliability assessment techniques. Numerical examples for our methods have been shown for explaining how to use our software safety assessment approaches conforming IEC 61508.


Author(s):  
Peter Cuninka ◽  
Maximilián Strémy

Abstract The article deals with different procedures for determining the safety integrity level and its applications. The purpose of this research was to evaluate the system and associate it with certain safety integrity level. In this article, we will use IEC 61508, IEC 61511 and IEC 62061 for comparison. The first standard is specified as the superior standard for all safety-critical systems. The second one acts as an extension of the superior standard in the field of functional safety. The last one is aimed at machinery safety.


Sign in / Sign up

Export Citation Format

Share Document