Evaluation of Two Automated Methods for Air-Void Analysis of Hardened Concrete

Author(s):  
A. M. Ramezanianpour ◽  
R. D. Hooton
2010 ◽  
Vol 7 (2) ◽  
pp. 102476 ◽  
Author(s):  
S. W. Dean ◽  
A. M. Ramezanianpour ◽  
R. D. Hooton

2013 ◽  
Vol 857 ◽  
pp. 110-115 ◽  
Author(s):  
Xiu Hua Zheng ◽  
Yong Ge ◽  
Jie Yuan

Air-entraining agent turely is one of the necessary compositions of the high durability concrete. The influence of air content and vibration time on the frost resistance of concrete was researched, and air void characteristics of hardened concrete was analysed. The results showed that the air contents could reduce the compressive strengthof hardened concrete excessively, but it made the spacing factor reduce obviously and significantly improve the frost resistance of concrete.The air voids with different structure in concrete were realized by vibration time. It was found that the air void structure and the frost resistance properties were influenced by the vibration time largely. The optimized vibration time is 30s, the appropriate vibration time is 20s~30s, no more than 35s.


1996 ◽  
Vol 23 (5) ◽  
pp. 1118-1128 ◽  
Author(s):  
François Saucier ◽  
Richard Pleau ◽  
Daniel Vézina

Since 1993, the Quebec Department of Transportation requires all its concrete suppliers to demonstrate that their concrete satisfies the requirements of the CSA A23.1 standard as regards the maximum spacing factor of the air void system. This new requirement raises questions about the reproducibility of the ASTM C 457 test method. An interlaboratory study was carried out to verify if the variability of the test method is sufficiently low to allow reliable decisions on the acceptance or rejection of in-place hardened concrete. A total of 18 operators from 13 different laboratories microscopically examined the six concrete slabs used for the study. It is concluded that the average reproducibility coefficient of variation is 14.4% for the total air content measurement and 14.2% for the spacing factor measurement. Considering these results, the probability that the measured value of the spacing factor exceeds the mandatory limit of 230 μm on a concrete production containing an air void system with a spacing factor of 170 μm (the target value proposed in the CSA A23.1 M-94 standard) is less than 0.7% (a probability of error of about 1%, 5%, or 10% is typical of most quality control test methods). Key words: concrete, air content, air void measurement, spacing factor, ASTM C 457 standard, interlaboratory study, freeze–thaw durability.


2019 ◽  
Vol 71 (13) ◽  
pp. 680-689 ◽  
Author(s):  
Zhichao Liu ◽  
Will Hansen ◽  
Fazhou Wang ◽  
Wenqin Zhang

2017 ◽  
Vol 45 (5) ◽  
pp. 20150424 ◽  
Author(s):  
Y. Song ◽  
R. Zou ◽  
D. I. Castaneda ◽  
K. A. Riding ◽  
D. A. Lange

2013 ◽  
Vol 771 ◽  
pp. 29-33
Author(s):  
Jin Xi Zhang ◽  
Chao Wang ◽  
Ming Yang Guo ◽  
Mao Cheng Ma

This paper studies the effect of water-cement ratio [w/ on the air-void parameters of cement concrete, which has a significant influence on the durability of concrete. Based on the experimental investigation, it is found that the impact on the air content of hardened concrete due to different water-cement ratio is not great. Test results also indicate that with the increase of water-cement ratio, the spacing factors also experienced a marked rise, and the mean diameters as well as the specific areas of air voids evidently increased or declined, respectively, which may lead to an adverse effect on the frost resistance of concrete.


Sign in / Sign up

Export Citation Format

Share Document