Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry for redox speciation of plutonium

2005 ◽  
Vol 93 (11) ◽  
Author(s):  
Chrystel Ambard ◽  
Arnaud Delorme ◽  
Nicolas Baglan ◽  
Jean Aupiais ◽  
Fabien Pointurier ◽  
...  

SummaryA robust and efficient interface between a capillary electrophoresis (CE) and an ICP-MS for actinide speciation studies was developed. This interface was made of two stainless steel T-shape pieces connected to the ICP-MS through a PFA-50 nebulizer. Fast separations (typically in less that 15 min) were obtained. The performances of the technique in terms of chemical separations carried out by the capillary electrophoresis and in terms of detection limits were investigated. Concerning the detection limit of the CE-ICP-MS system for plutonium, it was determined as 5 × 10

2018 ◽  
Vol 33 (6) ◽  
pp. 1031-1040 ◽  
Author(s):  
Claire Dalencourt ◽  
Annie Michaud ◽  
Azza Habibi ◽  
Alexa Leblanc ◽  
Dominic Larivière

Rapid and selective method for radium quantification with interference removal by cationic resin and ICP-MS/MS, leading to a detection limit of 10 fg L−1 for 226Ra and 228Ra.


2011 ◽  
Vol 383-390 ◽  
pp. 790-795
Author(s):  
Bao Hui Li ◽  
Bao Juan Tian

A method for mercury high throughput rapid speciation analysis was built by short column capillary electrophoresis (SC-CE) coupled with inductively coupled plasma mass spectrometry (ICP-MS). A micromist nebulizer was employed to increase the nebulization efficiency and a laboratory-made removable SC-CE-ICP-MS interface on the basis of cross design was applied to alleviate buffer contamination of ICP-MS. In less than 60 s methylmercury (MeHg(I)) and inorganic mercury (Hg(II)) were separated in a 16 × 75 μm i.d. short column fused-silica capillary at 21 kV, while a mixture of 30 mmol/L boric aicd + 5% (v/v) CH3OH (pH=8.60) acted as running electrolyte. The precisions (RSD, n=5) of migration time and peak area for MeHg(I) and Hg(II) were in the range of 1.4-2.6% and 3.3-3.4%, respectively. The limits of detection (3σ) mercury species were 9.7 and 12.0 μg/L, respectively. The recoveries for Hg(II) MeHg(I) were in the range of 96-107% and 99-105%.


2007 ◽  
Vol 95 (8) ◽  
Author(s):  
S. Bürger ◽  
N. L. Banik ◽  
R. A. Buda ◽  
Jens Volker Kratz ◽  
B. Kuczewski ◽  
...  

For the speciation of the plutonium oxidation states in aqueous solutions, the online coupling of capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Depending on the radius/electrical charge ratio, the oxidation states III, IV, V, and VI of plutonium are separated by CE, based on the different migration times through the capillary and are detected by ICP-MS. The detection limit is 20 ppb,