scholarly journals LUMEN-APPOSING METAL STENT AND ELETROCAUTERY ENHANCED DELIVERY SYSTEM (HOT AXIOSTM) FOR DRAINAGE OF WALLED-OFF NECROSIS: THE FIRST BRAZILIAN CASE REPORT

Author(s):  
Diogo Turiani HOURNEAUX DE-MOURA ◽  
Galileu Ferreira Ayala FARIAS ◽  
Vitor Ottoboni BRUNALDI ◽  
Caio Vinicius TRANQUILLINI ◽  
Marcos Eduardo Lera DOS-SANTOS ◽  
...  
2021 ◽  
Vol 09 (07) ◽  
pp. E1108-E1115
Author(s):  
Sudhir Maharshi ◽  
Shyam Sunder Sharma ◽  
Sandeep Ratra ◽  
Bharat Sapra ◽  
Dhruv Sharma

Abstract Background and study aims Walled-off necrosis (WON) is a known complication of acute necrotizing pancreatitis (ANP). There is no study comparing nasocystic irrigation with hydrogen peroxide (H2O2) versus biflanged metal stent (BMS) in the management of WON. The aim of this study was to compare the clinical efficacy of both the treatment strategies. Patients and methods This study was conducted on patients with symptomatic WON who were randomized to nasocystic irrigation with H2O2 (Group A) and BMS placement (Group B). Primary outcomes were clinical and technical success while secondary outcomes were procedure time, adverse events, need for additional procedures, duration of hospitalization, and mortality. Results Fifty patients were randomized into two groups. Group A (n = 25, age 37.8 ± 17.6 years, 16 men) and Group B (n = 25, age 41.8 ± 15.2 years, 17 men). There were no significant differences in baseline characteristics between the two groups. The most common etiology of pancreatitis was alcohol, observed in 27 (54 %) patients. Technical success (100 % vs 96 %, P = 0.98), clinical success (84 % vs 76 %, P = 0.76), requirement of additional procedures (16 % vs 24 %, P = 0.70) and adverse events (4 vs 7, P = 0.06) were comparable in both the groups. The duration to clinical success (34.4 ± 12 vs 14.8 ± 10.8 days, P = 0.001) and procedure time (36 ± 15 vs 18 ± 12 minutes, P = 0.01) were longer in Group A compared to Group B. Conclusions Nasocystic irrigation with H2O2 and BMS are equally effective in the management of WON but time to clinical success and procedure time is longer with nasocystic irrigation.


Vascular ◽  
2021 ◽  
pp. 170853812110627
Author(s):  
Julian Smith ◽  
Simon Joseph ◽  
Catherine Thoo

Background The Zenith endovascular graft (Cook Medical, Bloomington, IN, USA) is a well-recognised device used in endovascular repair of abdominal aortic aneurysms (EVAR). After a small number of reported cases of suprarenal stent separation from the main body of the graft, modifications were made to the strength and durability of the suture line attachment of the proximal bare metal component prior to release in 2003. This report describes a further case of suprarenal stent separation and type IA endoleak in a patient who underwent an EVAR using the Zenith device in 2012. Methods We present a case report of a 77-year-old male with incidental finding of type IA endoleak on a background of elective endovascular repair for 50.4-mm infrarenal abdominal aortic aneurysm (AAA), with a Cook Zenith endograft. Computed tomography (CT) demonstrated separation of the suprarenal bare metal stent from the main body of the endograft, with resultant graft migration and increase in native aneurysm sac size. Results The patient underwent semi-urgent surgery with successful placement of a bridging thoracic stent graft between the lowest renal artery and main body of the pre-existing graft. Conclusions This case report describes a rare complication of Zenith devices, additionally emphasising the importance of regular surveillance imaging following EVAR.


Sign in / Sign up

Export Citation Format

Share Document