scholarly journals Portal Vein Dopplerflowmetry in healthy sheep according to age

2017 ◽  
Vol 37 (10) ◽  
pp. 1172-1176 ◽  
Author(s):  
Alexandra F. Belotta ◽  
Bianca P. Santarosa ◽  
Danilo O.L. Ferreira ◽  
Sílvia M.F. Carvalho ◽  
Roberto C. Gonçalves ◽  
...  

ABSTRACT: Pulsed Doppler ultrasound was used to evaluate portal blood flow, portal velocity and portal congestion index in 24 healthy sheep divided into groups (lambs, yearlings and ewes), according to age. Measurements were performed at the 11th right intercostal space using ideal insonation angle and uniform insonation method. Mean values obtained in each group were compared with one-way ANOVA, followed by Tukey post-hoc test. Portal velocity and portal blood flow were statistically similar between the groups (P>0.05). Mean portal velocity were 17.75; 17.13 and 16.75; while mean portal blood flow were 26.65; 31.04 and 24.32 for lambs, yearlings and ewes, respectively. Portal congestion index was statistically distinct between the groups and values for lambs, yearlings and ewes were 0.009; 0.058 and 0.09, respectively (P<0.01). Statistical differences were observed in portal vein diameter, portal vein area and portal congestion index between the groups, presumably due to influence of weight and not to age.

Author(s):  
A. R. Monakhov ◽  
B. L. Mironkov ◽  
T. A. Dzhanbekov ◽  
K. O. Semash ◽  
Kh. M. Khizroev ◽  
...  

Introduction. Liver transplantation is a multi-component and complex type of operative treatment. Patients undergoing such a treatment sometimes are getting various complications. One of these complications is a portal hypertension associated with portal vein stenosis.Materials and methods. In 6 years after the left lateral section transplantation from living donor in a pediatric patient the signs of portal hypertension were observed. Stenosis of the portal vein was revealed. Due to this fact percutaneous transhepatic correction of portal vein stenosis was performed.Results. As a result of the correction of portal blood flow in the patient a positive trend was noted. According to the laboratory and instrumental methods of examination the graft had a normal function, portal blood flow was adequate. In order to control the stent patency Doppler ultrasound and MSCT of the abdominal cavity with intravenous bolus contrasting were performed. Due to these examinations the stent function was good, the rate of blood flow in the portal vein due to Doppler data has reached 80 cm/sec, and a decrease of the spleen size was noted.Conclusion. Diagnosis and timely detection of portal vein stenosis in patients after liver transplantation are very important for the preservation of graft function and for the prevention of portal hypertension. In order to do that, ultrasound Doppler fluorimetry examination needs to be performed to each patient after liver transplantation. In cases of violation of the blood flow in the portal vein CT angiography performance is needed. Percutaneous transhepatic stenting of portal vein is a minimally invasive and highly effective method of correction of portal hypertension. Antiplatelet therapy and platelet aggregation control are the prerequisites for successful stent function.


HPB Surgery ◽  
1994 ◽  
Vol 8 (1) ◽  
pp. 37-41
Author(s):  
L. Q. Wang ◽  
B. G. Persson ◽  
S. Bengmark

As liver tumours receive some of their blood supply from the portal vein, we wanted to illustrate the influence of portal blood flow in combination with dearterialization in the treatment of liver tumours. Forty male, inbred Wistar/Furth rats with an adenocarcinoma transplanted to the liver were treated with various inflow occlusions repeated daily for 5 days. Deviation of the portal blood flow alone with an end-side porto-caval shunt did not alter the tumour growth (p = 0.089). Thirty min of repeat dearterializations was potentiated by portal deviation so that tumour growth was delayed (p = 0.004). However, repeat dearterializations for 60 min in portal deviated rats induced irreversible liver damage and all rats died in a few days. Repeated dearterializations for 60 minutes alone retarded the tumour growth as efficiently (p = 0.007). Simultaneous occlusion of the hepatic artery and the portal vein for 30 minutes with a side-side porto-caval shunted (total devascularization) did not affect tumour growth (p = 0.154). Liver aminotransferases (ASAT and ALAT) were substantially increased following dearterialization for 30 min in rats with either an end-side or a side-side porto-caval shunt. Dearterialization for 60 min in rats with end-side porto-caval shunts gave a further release of ASAT and ALAT.In conclusion, portal deviation did not augment the therapeutic benefit of repeat dearterializations for the treatment of this experimental liver tumour. Repeat dearterializations alone seemed to be a feasible and efficient therapy for liver tumours.


2019 ◽  
Vol 1 (8) ◽  
pp. 26-29
Author(s):  
S. V. Peshkova ◽  
M. V. Chistyakova ◽  
V. S. Barcan

The paper analyzes the results of examinations of 24 patients with viral cirrhosis of classes B and C according to Child-Pugh criteria. The control group consisted of 16 healthy patients. Patients with viral cirrhosis were divided into 2 groups: 1 group consisted of 14 patients with pseudonormokinetic type of portal blood flow; Group 2-10 patients with hyperkinetic type of portal blood flow with predominant acceleration of the linear velocity in the portal vein. The average age of patients was 35.2 ± 7.4 years. Left ventricular myocardium mass and left ventricular myocardium mass index were determined in all the patients; the diameter and the maximum linear velocity in the main portal vein were measured using an Artida pro Toshiba apparatus, Japan. Heart rate variability was studied at rest and in active orfhostasis using the «Neuro-Soth)program, Ivanovo. it was found that in patients with liver cirrhosis the sympathetic effects of the autonomic nervous system predominated, which coincided with the literature data. It was also shown that in patients with the pseudonormokinetic type of portal blood flow these effects were more pronounced. The relationship between HRV indices and the formation of left ventricular hypertrophy in patients with pseudo-normokinetic type of portal blood flow was revealed.


1988 ◽  
Vol 254 (4) ◽  
pp. G495-G501 ◽  
Author(s):  
H. Orrego ◽  
F. J. Carmichael ◽  
V. Saldivia ◽  
H. G. Giles ◽  
S. Sandrin ◽  
...  

The mechanism by which ethanol induces an increase in portal vein blood flow was studied in rats using radiolabeled microspheres. Ethanol (2 g/kg) by gavage resulted in an increase of 50-70% in portal vein blood flow. The ethanol-induced increase in portal blood flow was suppressed by the adenosine receptor blocker 8-phenyltheophylline [ethanol, 61.8 +/- 4.1 ml.kg-1.min-1; ethanol + 8-phenyltheophylline (0.2 mg.kg-1.min-1), 44.2 +/- 2.0 ml.kg-1.min-1; P less than 0.05]. By itself, 8-phenyltheophylline (0.2 mg.kg-1.min-1) was without effect on cardiac output or portal blood flow. Adenosine infusion resulted in a dose-dependent increase in portal blood flow with a maximal effect at a dose of 0.17 mg.kg-1.min-1 (control, 41.3 +/- 2.3; adenosine, 81.7 +/- 8.0 ml.kg-1.min-1; P less than 0.05). This adenosine-induced increase in portal blood flow was inhibited by 8-phenyltheophylline in a dose-dependent manner [adenosine, 81.7 +/- 8.0 ml.kg-1.min-1; adenosine + 8-phenyltheophylline (0.2 mg.kg-1.min-1), 49.8 +/- 6.6 ml.kg-1.min; P less than 0.05]. Both alcohol and adenosine significantly reduced preportal vascular resistance by 40% (P less than 0.02) and 60% (P less than 0.01), respectively. These effects were fully suppressed by 8-phenyltheophylline. It is concluded that adenosine is a likely candidate to mediate the ethanol-induced increase in portal vein blood flow. It is suggested that an increase in circulating acetate and liver hypoxia may mediate the effects of alcohol by increasing tissue and interstitial adenosine levels.


1996 ◽  
Vol 271 (6) ◽  
pp. H2701-H2709 ◽  
Author(s):  
M. S. D'Almeida ◽  
S. Cailmail ◽  
D. Lebrec

Direct measurement of portal venous blood flow is technically difficult, yet crucial for accurate assessment of liver hemodynamic and metabolic functions. The aim of this investigation was to assess the feasibility of implanting transit-time ultra-sound (TTUS) perivascular flow probes on the portal vein of the rat and to validate this technique as a means of directly measuring portal blood flow in conscious rats. A TTUS flow probe was implanted on the portal veins of 10 rats. One week later, portal flow was measured under basal conditions in these rats by TTUS probes and after pharmacological manipulation of portal flow by intravenous injections of Glypressin or infusions of adenosine while the rats were conscious. Portal flow was simultaneously measured in the same rats using radioactive microspheres. Basal systemic hemodynamics, regional blood flows to splanchnic organs, and portal blood pressure were not significantly modified by the presence of the probe on the portal vein compared with a control group of rats not instrumented with flow probes. Basal portal flows measured by the TTUS and microsphere techniques were not different (20.6 +/- 2.6 and 17.6 +/- 1.3 ml/min). After Glypressin, portal flows measured by the TTUS and microsphere techniques were 12.3 +/- 2.9 and 9.3 +/- 1.9 ml/min and, in response to adenosine, increased to 27.2 +/- 3.4 and 31.3 +/- 4.1 ml/min. There was no significant difference between the TTUS and microsphere flows. Both the relationship between absolute flows and the relationship between changes in flows measured by the two techniques were linear with slopes approaching 1.0. Thus TTUS flow probes can be used to directly measure portal flow from the portal vein in conscious rats. This methodology is as effective as the standard technique of radioactive microspheres. More importantly, the TTUS technique allows for continuous direct measurement of portal flow and eliminates the hazards and sources of error associated with the radioactive microsphere technique.


Sign in / Sign up

Export Citation Format

Share Document