Evaluation of the residual service life of existing concrete structures: a valuable tool for maintenance planning

Author(s):  
T. Teruzzi
2019 ◽  
Vol 22 (7) ◽  
pp. 1631-1643
Author(s):  
Sushil Kumar Dhawan ◽  
Abhinav Bindal ◽  
Suresh Bhalla ◽  
Bishwajit Bhattacharjee

Concrete is primarily used in the form of reinforced concrete for construction of buildings, bridges and other important structures. Due to normal usage and environmental effects, the structure would gradually deteriorate. The actual residual life needs to be worked at a given time vis-à-vis the design life of the structure, commensurate with the fulfilment of essential requirements of structural integrity and safety and from strength as well as serviceability considerations. Requirements for residual life assessment would depend upon the current parameters, such as the residual cross-sectional area of concrete as well as steel, Young’s modulus of elasticity and the in situ material strength of the constituent materials, namely, concrete and steel. This article aims to develop a rigorous methodology for expected remaining service life of a reinforced concrete structure from wind/seismic considerations, based on the present condition of the structure encompassing the residual material strength and the residual reinforcement/sectional areas. The methodology development section is followed by an illustrative example and a parametric study involving a 10-storeyed reinforced concrete building frame under wind and earthquake loads. Influences of various parameters such as concrete strength and residual rebar area on the expected remaining service life are studied in detail. The proposed methodology provides a simple but rational estimation of the residual service life for reinforced concrete structures.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Amir Rahimi ◽  
Christoph Gehlen ◽  
Thorsten Reschke ◽  
Andreas Westendarp

This paper deals with the service life design of existing reinforced concrete structures in a marine environment. The general procedure of condition assessment for estimating the residual service life of structures before a repair measure is illustrated. For assessment of the residual service life of structures which have undergone a repair measure a simplified mathematical model of chloride diffusion in a 2-layer system is presented. Preliminary probabilistic calculations demonstrate the effect of various conditions on the residual service life. First studies of the chloride diffusion in a 2-layer system have been conducted using the finite element method. Results of a long-term exposure test are presented to illustrate the performance of two different repair materials. The distribution of residual chlorides after application of a repair material is being studied in laboratory investigations. The residual chlorides migrate from the concrete layer into the new layer immediately after the repair material has been applied to the concrete member. The content and gradient of residual chlorides, along with the thickness and the chloride ingress resistance of both the remaining and the new layer of cover, will determine the residual service life of the repaired structures.


2019 ◽  
Vol 12 (1) ◽  
pp. 56-62 ◽  
Author(s):  
A. O. Nedosekin ◽  
A. V. Smirnov ◽  
D. P. Makarenko ◽  
Z. I. Abdoulaeva

The article presents new models and methods for estimating the residual service life of an autonomous energy system, using the functional operational risk criterion (FOR). The purpose of the article is to demonstrate a new method of durability evaluation using the fuzzy logic and soft computing framework. Durability in the article is understood as a complex property directly adjacent to the complex property of system resilience, as understood in the Western practice of assessing and ensuring the reliability of technical systems. Due to the lack of reliable homogeneous statistics on system equipment failures and recoveries, triangular fuzzy estimates of failure and recovery intensities are used as fuzzy functions of time based on incomplete data and expert estimates. The FOR in the model is the possibility for the system availability ratio to be below the standard level. An example of the evaluation of the FOR and the residual service life of a redundant cold supply system of a special facility is considered. The transition from the paradigm of structural reliability to the paradigm of functional reliability based on the continuous degradation of the technological parameters of an autonomous energy system is considered. In this case, the FOR can no longer be evaluated by the criterion of a sudden failure, nor is it possible to build a Markov’s chain on discrete states of the technical system. Assuming this, it is appropriate to predict the defi ning functional parameters of a technical system as fuzzy functions of a general form and to estimate the residual service life of the technical system as a fuzzy random variable. Then the FOR is estimated as the possibility for the residual life of the technical system to be below its warranty period, as determined by the supplier of the equipment.


1993 ◽  
Vol 12 (2) ◽  
pp. 99-104
Author(s):  
V. Pilous ◽  
K. Stránský ◽  
P. Drybčák ◽  
P. Šlechta

Sign in / Sign up

Export Citation Format

Share Document