Diagnosis of tuberculous spondylitis

2021 ◽  
Vol 20 (4) ◽  
pp. 429-429
Author(s):  
M. Friedland

Diagnosis of tuberculous spondylitis in adults, especially in the absence of kyphosis and a characteristic response to the load of the spine, is often very difficult. Barr (Bulk md., No. 10, 1923) advises in such cases to pay special attention to various "neuralgic" phenomena, unilateral increase in tendon reflexes and Babinsk'oro symptom, as well as to limited rigidity of the spinal muscles.

Designs ◽  
2021 ◽  
Vol 5 (3) ◽  
pp. 39
Author(s):  
Maria Lazzaroni ◽  
Tommaso Poliero ◽  
Matteo Sposito ◽  
Stefano Toxiri ◽  
Darwin G. Caldwell ◽  
...  

The execution of manual material handling activities in the workplace exposes workers to large lumbar loads that increase the risk of musculoskeletal disorders and low back pain. In particular, the redesign of the workplace is making the execution of pulling activities more common, as an alternative to lifting and carrying tasks. The biomechanical analysis of the task revealed a substantial activation of the spinal muscles. This suggests that the user may benefit from the assistance of a back-support exoskeleton that reduces the spinal muscle activity and their contribution to lumbar compression. This work addresses this challenge by exploiting the versatility of an active back-support exoskeleton. A control strategy was specifically designed for assisting pulling that modulates the assistive torques using the forearm muscle activity. These torques are expected to adapt to the user’s assistance needs and the pulled object mass, as forearm muscle activity is considered an indicator of grip strength. We devised laboratory experiments to assess the feasibility and effectiveness of the proposed strategy. We found that, for the majority of the subjects, back muscle activity reductions were associated with the exoskeleton use. Furthermore, subjective measurements reveal advantages in terms of perceived support, comfort, ease of use, and intuitiveness.


2011 ◽  
Vol 11 (03) ◽  
pp. 471-513 ◽  
Author(s):  
ROBERT LEMOYNE ◽  
TIMOTHY MASTROIANNI ◽  
CRISTIAN COROIAN ◽  
WARREN GRUNDFEST

The deep tendon reflex is a fundamental aspect of a neurological examination. The two major parameters of the tendon reflex are response and latency, which are presently evaluated qualitatively during a neurological examination. The reflex loop is capable of providing insight into the status and therapy response of both upper and lower motor neuron syndromes. Attempts have been made to ascertain reflex response and latency; however, these systems are relatively complex, resource intensive, with issues of consistent and reliable accuracy. The solution presented is a wireless quantified reflex device using tandem three-dimensional (3D) wireless accelerometers to obtain response based on acceleration waveform amplitude and latency derived from temporal acceleration waveform disparity. Three specific aims have been established for the proposed wireless quantified reflex device: (1) Demonstrate the wireless quantified reflex device is reliably capable of ascertaining quantified reflex response and latency using a quantified input. (2) Evaluate the precision of the device using an artificial reflex system. (3) Conduct a longitudinal study respective of subjects with healthy patellar tendon reflexes, using the wireless quantified reflex evaluation device to obtain quantified reflex response and latency. Aim 1 has led to a steady evolution of the wireless quantified reflex device from a singular 2D wireless accelerometer capable of measuring reflex response to a tandem 3D wireless accelerometer capable of reliably measuring reflex response and latency. The hypothesis for aim 1 is that a reflex quantification device can be established for reliably measuring reflex response and latency for the patellar tendon reflex, comprised of an integrated system of wireless 3D MEMS accelerometers. Aim 2 further emphasized the reliability of the wireless quantified reflex device by evaluating an artificial reflex system. The hypothesis for aim 2 is that the wireless quantified reflex device can obtain reliable reflex parameters (response and latency) from an artificial reflex device. Aim 3 synthesizes the findings relevant to aim 1 and 2, while applying the wireless accelerometer reflex quantification device to a longitudinal study of healthy patellar tendon reflexes. The hypothesis for aim 3 is that during a longitudinal evaluation of the deep tendon reflex the parameters for reflex response and latency can be measured with a considerable degree of accuracy, reliability, and reproducibility. Enclosed is a detailed description of a wireless quantified reflex device with research findings and potential utility of the system, inclusive of a comprehensive description of tendon reflexes, prior reflex quantification systems, and correlated applications.


1998 ◽  
Vol 64 (2) ◽  
pp. 253-255 ◽  
Author(s):  
S Manschot ◽  
L van Passel ◽  
E Buskens ◽  
A Algra ◽  
J van Gijn

1990 ◽  
Vol 53 (8) ◽  
pp. 667-670 ◽  
Author(s):  
A Filla ◽  
G De Michele ◽  
F Cavalcanti ◽  
A Perretti ◽  
L Santoro ◽  
...  

1993 ◽  
Vol 66 (5) ◽  
pp. 1328-1332 ◽  
Author(s):  
Nobuyuki Mohri ◽  
Yoshio Katsuya ◽  
Satoshi Nakata ◽  
Ken-ichi Yoshikawa

Sign in / Sign up

Export Citation Format

Share Document