gold electrode
Recently Published Documents


TOTAL DOCUMENTS

1960
(FIVE YEARS 204)

H-INDEX

74
(FIVE YEARS 9)

Polymers ◽  
2022 ◽  
Vol 14 (2) ◽  
pp. 305
Author(s):  
Anwar ul Haq Ali Shah ◽  
Sadaf Zia ◽  
Gul Rahman ◽  
Salma Bilal

Electronically conducting poly (aniline-co-2-hydroxyaniline) (PACHA), a copolymer of aniline and 2-hydroxyaniline (2HA), was electrochemically coated on gold substrate for methanol electrooxidation in alkaline media. The electrochemical behavior of PACHA coated gold electrode towards methanol electrooxidation was investigated via cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) for application in an alkaline fuel cell. Methanol electrooxidation was observed at two different electrode potentials depending on the concentration of the base. At the PACHA coated gold electrode, the methanol oxidation peak was observed at lower overpotential (at 0.19 V) in a solution of high base concentration (1.8 M NaOH), which was 30 mV lower than the peak for the uncoated gold electrode. In addition, the Faradic current Imax obtained on the PACHA coated electrode (20 mA) was two times higher as compared to the Faradic current Imax of the un-modified gold electrode (10 mA). In solution of lower base concentration (0.06 M NaOH), the electrooxidation of methanol became sluggish on both electrodes, as indicated by peak shifting towards positive potential and with reduced faradaic current (at 0.74 V on PACHA coated electrode; Imax 10 mA). The electrooxidation of methanol at both lower and higher electrode potentials was analyzed mechanistically and discussed in light of the literature. EIS results were interpreted using Nyquist and Bode plots. The charge transfer resistance was decreased and pseudo-capacitive behavior changed to conductive behavior when external applied potential was increased from 0.1 V to 0.4 V.


Coatings ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 49
Author(s):  
Veton Haziri ◽  
Sereilakhena Phal ◽  
Jean-François Boily ◽  
Avni Berisha ◽  
Solomon Tesfalidet

Surface modification is a hot topic in electrochemistry and material sciences because it affects the way materials are used. In this paper, a method for covalently attaching carboxyphenyl (PhCOOH) groups to a gold electrode is presented. These groups were grafted onto the electrode surface electrochemically via reduction of aryldiazonium salt. The resulting grafted surface was characterized using cyclic voltammetry (CV) before and after the functionalization procedure to validate the presence of the grafted layer. The grafting of PhCOOH groups was confirmed by analyzing electrode thickness and composition by ellipsometry and X-ray photoelectron spectroscopy (XPS). Density functional theory (DFT) calculations indicated that the grafted layers provide a stable platform and resolved, for the first time, their interactions with oxygen.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7733
Author(s):  
Daria Rudewicz-Kowalczyk ◽  
Iwona Grabowska

An elevated level of low density lipoprotein (LDL) can lead to the cardiovascular system-related diseases, such as atherosclerosis and others. Therefore, fast, simple, and accurate methods for LDL detection are very desirable. In this work, the parameters characterizing the electrochemical immuno-and aptasensor for detection of LDL have been compared for the first time. An immunosensor has been designed, for which the anti-apolipoprotein B-100 antibody was covalently attached to 4-aminothiophenol (4-ATP) on the surface of the gold electrode. In the case of an aptasensor, the gold electrode was modified in a mixture of ssDNA aptamer specific for LDL modified with –SH group and 6-mercaptohexanol. Square-wave voltammetry has been used for detection of LDL in PBS containing redox active marker, [Fe(CN)6]3−/4−. Our results show the linear dependence of [Fe(CN)6]3−/4− redox signal changes on LDL concentration for both biosensors, in the range from 0.01 ng/mL to 1.0 ng/mL. The limit of detection was 0.31 and 0.25 ng/mL, for immuno- and aptasensor, respectively. Whereas slightly better selectivity toward human serum albumin (HSA), high density lipoprotein (HDL), and malondialdehyde modified low density lipoprotein (MDA-LDL) has been observed for aptasensor. Moreover, the other components of human blood serum samples did not influence aptasensor sensitivity.


2021 ◽  
Author(s):  
Pralhad Namdev Joshi ◽  
Evgeniy Mervinetsky ◽  
Ohad Solomon ◽  
Yu-Ju Chen ◽  
Shlomo Yitzchaik ◽  
...  

Kinases are important cancer biomarkers and are conventionally detected based on their catalytic activity. Kinases regulate cellular activities by phosphorylation of motif-specific multiple substrate proteins, resulting in a lack of selectivity of activity-based kinase biosensors. We present an alternative approach of sensing kinases based on the interactions of their allosteric docking sites with a specific partner protein. The new approach was demonstrated for the ERK2 kinase and its substrate ELK-1. A peptide derived from ELK-1 was bound to a gold electrode and ERK2 sensing was performed by electrochemical impedance spectroscopy. The sensors showed a high level of target selectivity for ERK2 when compared with p38gamma kinase and BSA. ERK2 was detected in its cellular concentration range, 0.2-8.0 microM. Using the flexibility of peptide design, our method is generic for developing sensitive and substrate-specific biosensors and other disease-related enzymes based on their interactions.


Biosensors ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 451
Author(s):  
Ping Ouyang ◽  
Chenxin Fang ◽  
Jialun Han ◽  
Jingjing Zhang ◽  
Yuxing Yang ◽  
...  

The qualitative and quantitative determination of marker protein is of great significance in the life sciences and in medicine. Here, we developed an electrochemical DNA biosensor for protein detection based on DNA self-assembly and the terminal protecting effects of small-molecule-linked DNA. This strategy is demonstrated using the small molecule biotin and its receptor protein streptavidin (SA). We immobilized DNA with a designed structure and sequence on the surface of the gold electrode, and we named it M1-Biotin DNA. M1-Biotin DNA selectively combines with SA to generate M1-Biotin-SA DNA and protects M1-Biotin DNA from digestion by EXO III; therefore, M1-Biotin DNA remains intact on the electrode surface. M1-Biotin-SA DNA was modified with methylene blue (MB); the MB reporter molecule is located near the surface of the gold electrode, which generates a substantial electrochemical signal during the detection of SA. Through this strategy, we can exploit the presence or absence of an electrochemical signal to provide qualitative target protein determination as well as the strength of the electrochemical signal to quantitatively analyze the target protein concentration. This strategy has been proven to be used for the quantitative analysis of the interaction between biotin and streptavidin (SA). Under optimal conditions, the detection limit of the proposed biosensor is as low as 18.8 pM, and the linear range is from 0.5 nM to 5 μM, showing high sensitivity. The detection ability of this DNA biosensor in complex serum samples has also been studied. At the same time, we detected the folate receptor (FR) to confirm that this strategy can be used to detect other proteins. Therefore, this electrochemical DNA biosensor provides a sensitive, low-cost, and fast target protein detection platform, which may provide a reliable and powerful tool for early disease diagnosis.


2021 ◽  
Author(s):  
İpek Avcı ◽  
Merve Oğuz ◽  
Mustafa Şen

Here, an extended – gate field effect transistor (EGFET) pH microsensor was developed for use in fast and sensitive pH measurement applications. The system consisted of two components; a pH sensitive modified gold electrode and a simple and cheap metal oxide semiconductor field-effect transistor (MOSFET). Polypyrrole, a semiconductor and pH responsive polymer, was formed by electropolymerization of pyrrole monomer at the surface of the gold electrode in galvostanic mode. Then, measurements were made in PBS at different pH values using the pH sensitive electrode. In this context, the pH sensitivity of polypyrrole with respect to electropolymerization and incubation time were studied. According to the results, the EGFET pH microsensor formed by 4-min pyrrole electropolymerization showed at pH 6-12 the highest pH sensitivity with 67 mV/pH


Sign in / Sign up

Export Citation Format

Share Document