scholarly journals Outcome of pedicle screw fixation with transpedicular bone grafting in fracture of thoracolumbar vertebrae

Author(s):  
Harpreet Singh ◽  
Aliasgar J. Rampurwala ◽  
Tej S. Rudani ◽  
Malay P. Gandhi

<p class="abstract"><strong>Background:</strong> Posterior short segment instrumentation for thoracolumbar fracture is known for high implant failure rate because of the lack of anterior support. Anterior body augmentation by transpedicular bone grafting has been developed as an alternative to overcome this failure. In this study, we have evaluated the outcome of the cases of the unstable thoracolumbar spine injuries managed surgically with pedicle screws and transpedicular bone grafting.</p><p class="abstract"><strong>Methods:</strong> 20 patients were included in this study and were followed up for up to 6 months postoperatively. We assessed the outcome of each patient with Frankel scale and visual analog score (VAS) post-operatively clinically and radio logically by measuring Cobb’s angle and anterior vertebral body height post-operatively on follow-up at 6 weeks, 12 weeks, and 24 weeks.<strong></strong></p><p class="abstract"><strong>Results:</strong> We found that males had higher incidence with most common mode of injury was fall from height. D12 was single most involved vertebrae. The average Cobb’s angle during preoperative stage was 12 degrees and 22.05 degrees at 6th week and this was maintained till 24th week. The mean difference of anterior vertebral body height between pre-operative and 24th post-operative week was 7.15 mm. The mean VAS pre-operatively was 9.8 which changed to 0.75 at 24 weeks follow up. These were statistically highly significant.</p><p class="abstract"><strong>Conclusions:</strong> Our study established that Pedicle screw fixation with transpedicular bone grafting has a satisfactory result and can restore vertebral height, increase the stability of the injured vertebrae and leads to a significant improvement in the patient’s quality of life.</p>

Author(s):  
Naushad Hussain ◽  
Nirmal Dhananjay Patil ◽  
Hiren Patel ◽  
Akash Shakya

<p class="abstract"><strong>Background:</strong> Pedicle screw instrumentation in case of fracture spine provides stable fixation. However in absence of experience and proper technique of pedicle screw insertion, it is associated with many complications. We aim to study the results of patients with thoracolumbar fracture stabilized with short segment pedicle screw instrumentation.</p><p class="abstract"><strong>Methods:</strong> 33 cases of thoracolumbar wedge compression fracture spine presenting to Nair Hospital were included in the study. All patients were operated by the senior author via a posterior approach and short segment pedicle screw fixation. Patients were followed up for one year.<strong></strong></p><p class="abstract"><strong>Results:</strong> 33 patients with a mean age were 37.6 years of which 3 were females and 30 were males in our study. Fall from height (93.93%) was the most common mode of injury followed by road traffic accident (6.07%). D12 and L1 were the most common vertebrae involved. Statistically significant (p=0.01) correction in the vertebral body height occurred in the immediate postop period and there was 4.1% loss of correction at final follow-up. There was statistically significant improvements in the Regional angle (p=0.03) and anterior wedge angle (p=0.03). Residual regional angle at final follow-up was found to be &gt;5° in 3 patients. Neurological improvement was seen in 23 (74.19%) patients (p=0.01). No improvements were seen in 8 (25.81%) patients. None of our patients had postoperative worsening of the neurological status. None of the patients had pedicle wall breach on final follow up CT scan.</p><p class="abstract"><strong>Conclusions:</strong> Short segment fixation in case of wedge fracture can restore the vertebral body height, mean regional angle and mean anterior wedge angle and provide good outcome. There are poor chances of recovery of patient with Frankel grade A. Meticulous dissection and careful technique of pedicle screw insertion, adequate decompression, good contouring of the rod with correction of kyphosis can provide excellent results.</p>


2020 ◽  
Vol 21 (1) ◽  
Author(s):  
Xuhong Xue ◽  
Sheng Zhao

Abstract Background The management of thoracolumbar burst fractures traditionally involves posterior pedicle screw fixation, but it has some drawbacks. The aim of this study is to evaluate the clinical and radiological outcomes of patients with thoracolumbar burst fractures. They were treated by a modified technique that monoaxial pedicle screws instrumentation and distraction-compression technology assisted end plate reduction. Methods From March 2014 to February 2016, a retrospective study including 42 consecutive patients with thoracolumbar burst fractures was performed. The patients had undergone posterior reduction and instrumentation with monoaxial pedicle screws. The fractured vertebrae were also inserted screws as a push point. The distraction -compression technology was used as assisting end plate reduction. All patients were followed up at a minimum of 2 years. These parameters including segmental kyphosis, severity of fracture, neurological function, canal compromise and back pain were evaluated in preoperatively, postoperatively and at the final follow-up. Results The average follow-up period was 28.9 ± 4.3 months (range, 24-39mo). No patients had postoperative implant failure at recent follow-up. The mean Cobb angle of the kyphosis was improved from 14.2°to 1.1° (correction rate 92.1%). At final follow-up there was 1.5% loss of correction. The mean preoperative wedge angle was improved from 17.1 ± 7.9°to 4.4 ± 3.7°(correction rate 74.3%). The mean anterior and posterior vertebral height also showed significant improvements postoperatively, which were maintained at the final follow-up(P < 0.05). The mean visual analogue scale (VAS) scores was 8 and 1.6 in preoperation and at the last follow-up, and there was significant difference (p < 0.05). Conclusion Based on our experience, distraction-compression technology can assist reduction of collapsed endplate directly. Satisfactory fracture reduction and correction of segmental kyphosis can be achieved and maintained with the use of monoaxial pedicle screw fixation including the fractured vertebra. It may be a good treatment approach for thoracolumbar burst fractures.


2020 ◽  
Author(s):  
Chao Lou ◽  
Weiyang Yu ◽  
Zhenzhong Chen ◽  
Kangtao Jin ◽  
Jiawei Gao ◽  
...  

Abstract Objective: This study aimed to assess the feasibility as well as the clinical and radiological outcomes of posterior percutaneous pedicle screw fixation (PPSF) combined with anterior monosegmental column reconstruction in unstable thoracolumbar burst fractures. Methods: From January 2011 to August 2017, thirty-five patients with unstable thoracolumbar burst fractures were enrolled in this study. The patients underwent posterior PPSF combined surgery with delayed anterior monosegmental reconstruction utilizing titanium mesh cages. Clinical outcomes, radiological parameters, and treatment-related complications were assessed. Results: The mean age of the patients was 44.8 years. The mean operative time and blood loss were 205 min and 560 ml, respectively. The mean follow-up period was 25.2 months. The Visual analog scale (VAS) pain score was significantly improved postoperatively, and the improvement was maintained until the final follow-up. The mean sagittal kyphosis was corrected from 16.3 preoperatively to 1.5 postoperatively, which increased slightly to 2.6 at the final follow-up. In 24 patients with neurologic dysfunction, 21 (87.5 %) patients had improvement after surgery. None obvious subsidence of the titanium mesh cage and none dislodgement, loosening or breakage of the instrumentation was observed in any patient during the follow-up period. Solid bony fusion was achieved in all patients. Conclusions: Combined posterior PPSF with delayed anterior monosegmental column reconstruction for unstable thoracolumbar burst fractures can produce good clinical and radiological outcomes.


2020 ◽  
Vol 9 (12) ◽  
pp. 4002
Author(s):  
Masashi Uehara ◽  
Shugo Kuraishi ◽  
Shota Ikegami ◽  
Hiroki Oba ◽  
Takashi Takizawa ◽  
...  

Skip pedicle screw fixation for adolescent idiopathic scoliosis (AIS) requires fewer screws and can reduce the risk of neurovascular injury as compared with segmental pedicle screw fixation. However, the long-term impact of screw number reduction on correction and clinical results is unclear. This study examined the 10-year post-operative outcomes of skip pedicle screw fixation for patients with AIS. We reviewed the outcomes of 30 patients who underwent skip pedicle screw fixation for AIS. Radiological and clinical findings were assessed before and immediately, 2 years, and 10 years after surgery in the remaining 25 patients. The mean Cobb angle of the main curve preoperatively and immediately, 2 years, and 10 years post-operatively was 59.4°, 23.4°, 25.8°, and 25.60°, respectively, and was significantly improved at all post-surgical time points (all p < 0.001). The mean correction rate immediately after surgery was 60.8%, and the correction loss rate at the observation end point was 4.8%. The Cobb angle of the lumbar curve was significantly improved immediately after surgery, and the correction persisted until 10 years post-operatively. Remarkable gains were observed for most Scoliosis Research Society-22 patient questionnaire sub-scores at the final follow-up versus preoperative assessments. In conclusion, good correction of the AIS deformity by skip pedicle screw fixation was well maintained over a long follow-up period of 10 years, with clinically meaningful gains in Society-22 patient questionnaire sub-scores.


2006 ◽  
Vol 5 (6) ◽  
pp. 534-539 ◽  
Author(s):  
Aaron R. Cutler ◽  
Saquib Siddiqui ◽  
Mohan Avinash L. ◽  
Virany H. Hillard ◽  
Franco Cerabona ◽  
...  

Object Transforaminal lumbar interbody fusion (TLIF) is an accepted alternative to circumferential fusion of the lumbar spine in the treatment of degenerative disc disease, spondylolisthesis, and recurrent disc herniation. To maintain disc height while arthrodesis takes place, the technique requires the use of an interbody spacer. Although titanium cages are used in this capacity, the two most common spacers are polyetheretherketone (PEEK) cages and femoral cortical allografts (FCAs). The authors compared the clinical and radiographic outcomes of patients who underwent TLIF with pedicle screw fixation, in whom either a PEEK cage or an FCA was placed as an interbody spacer. Methods The charts and x-ray films obtained in 39 patients (age range 33–68 years, mean 44.7 years) who underwent single-level TLIF between October 2001 and April 2004 and in whom either a PEEK cage (18 patients) or FCA (21 patients) was placed as an interbody spacer were evaluated in a retrospective study. Radiological outcome was based on fusion rate and a comparison of the initial postoperative lordotic angle on standing lateral radiographs with that at long-term follow up (mean follow up 15.1 months, minimum 12 months). To control for variations in radiographic magnification, the authors used lordotic angle as an indirect measure of disc space height. Clinical outcome was assessed using the Oswestry Disability Index (ODI). There were no major complications in either group. Radiographically documented fusion occurred in all patients in the PEEK group and 95.2% of those in the FCA group. Pseudarthrosis developed in one patient in the FCA group, and this patient underwent additional surgery. In both groups, the mean lordotic angle changed by less than 2.20° during the postoperative period, and the mean postoperative ODI score was more than 40 points lower than the mean preoperative score. There was no significant difference between the two groups in mean change in lordotic angle (p = 0.415) and mean change in ODI score (p = 0.491). Conclusions Both PEEK cages and FCAs are highly effective in promoting interbody fusion, maintaining postoperative disc space height, and achieving desirable clinical outcomes in patients who undergo TLIF with pedicle screw fixation. The advantages of PEEK cages include a lower incidence of subsidence and their radiolucency, which permits easier visualization of bone growth.


2016 ◽  
Vol 9 (2) ◽  
pp. 81
Author(s):  
Md. Kamrul Ahsan ◽  
Zabed Zahangiri ◽  
M. A. Awwal ◽  
Naznin Zaman ◽  
Md. Hamidul Haque ◽  
...  

<p>The aim of this study was to evaluate the efficacy of inclusion of the fractured vertebra in short segment fixation in terms of clinical and the radiological outcomes in unstable thoracolumbar junction burst fractures at a minimum of 1 year follow-up. Records of 52 patients (age: 21-50 years) with thoracolumbar burst fracture (T10–L2) in Magerl Type A fractures underwent posterior pedicle screw fixation including the fractured vertebra. Clinical parameters were back pain using Visual Analogue Score (VAS) and disability using Oswestry disability index (ODI), neurological deficit (using ASIA grade) and radiologic parameters (Cobb angle, the kyphotic deformation and vertebral height) were measured before surgery and at 3, 6 and 12 months  post-operatively. The presence of screw breakage, screw pullout, peri-implant loosening, and rod breakage were considered as criteria for implant failure. The majority of fractures resulted due to falls (31 cases), and the remaining cases resulted from car accidents (21 cases). The fractured vertebral body level was L1, T12, L2, T11, and T10 in 23, 17, 6, 4 and 2 cases and achieved satisfactory clinical outcomes according to the modified Mcnab criteria 18, 25, 6 and 3 cases were considered to have excellent, good, fair, and poor outcome. The mean kyphotic angle at pre-, post-operative and final follow-up was 13.5 ± 6.3, 13.4 ± 4.3, 8.5 ± 6.  The average loss of kyphosis correction was 6.4 ± 5.2° at the final follow-up. The mean pre- and post-operative kyphotic deformation of vertebral body was 5.1 ± 3.2, 4.8 ± 2.3 and at final follow-up was 4.5 ± 4.0 (p&gt;0.05). The mean anterior and posterior vertebral height also showed significant improvements post-operatively, which were maintained at the final follow-up. The mean ODI and VAS scores at the end of 1 year were 17.4%, 1.7 respectively. There was no case of major complication after surgery and during the follow-up period. In conclusion, reduction of unstable thoracolumbar junction burst fracture can be achieved and maintained with the use of short-segment pedicle screw fixation including the fractured vertebra, avoiding the need for anterior reconstruction.</p><p> </p>


BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Derong Xu ◽  
Shuo Han ◽  
Chao Wang ◽  
Kai Zhu ◽  
Chuanli Zhou ◽  
...  

Abstract Background Uniportal full endoscopic posterolateral transforaminal lumbar interbody fusion (Endo-TLIF) with percutaneous pedicle screw fixation is a promising, minimally invasive method for the treatment of lumbar spondylolisthesis. However, repeated radiation exposure from X-rays and the steep learning curve remain to be improved. Methods This retrospective study explored the effects of electromagnetic navigation on improving Endo-TLIF with percutaneous pedicle screw fixation. Clinical information from 42 patients who had received Endo-TLIF with percutaneous pedicle screw fixation from May 2019 to November 2020 was analyzed retrospectively. The procedures were assisted under electromagnetic navigation. The rate of adjustment for guide wires, frequency of X-ray exposure, operative time, accuracy of pedicle screw location, and clinical outcomes were recorded. Results The mean follow-up for 42 patients was 11.9 ± 3.1 months. The mean age of the patients was 56.1 ± 9.26 years, with a female/male ratio of 25:17. According to postoperative CT scans and 3D reconstructions, the excellent and good rate of pedicle screws was 96.4%. The rate of adjustment for guide wires under the assistance of electromagnetic navigation was 1.78%, and the frequency of X-ray exposure was 8.27 ± 1.83. The operative time was 167.25 ± 28.16 min, including the duration of guide wire insertion (14.63 ± 5.45 min) and duration of decompression and cage placement (75.43 ± 13.97 min). The duration of hospitalization after operation was 2.59 ± 1.16 days. The preoperative VAS score was 7.51 ± 1.91, and the preoperative ODI was 82.42 ± 8.7%. At the last follow-up, the VAS score was 2.09 ± 0.59, and the ODI was 11.09 ± 3.2%. There were statistically significant improvements in the VAS score and ODI in all patients at the follow-up (p < 0.05). Conclusions Electromagnetic navigation can provide accurate positioning and guidance in real time, which improves the surgical efficiency of percutaneous pedicle screw placement and endoscopic decompression in Endo-TLIF with reduced radiation exposures.


2018 ◽  
Vol 2018 ◽  
pp. 1-8 ◽  
Author(s):  
Panagiotis Korovessis ◽  
Eva Mpountogianni ◽  
Vasileios Syrimpeis ◽  
Andreas Baikousis ◽  
Vasileios Tsekouras

Introduction. Polymethacrylate (PMMA) is commonly used in vertebroplasty and balloon kyphoplasty, but its use has been associated with complications. This study tests three hypotheses: (1) whether strontium hydroxyapatite (Sr-HA) is equivalent to PMMA for restoring thoracolumbar vertebral body fractures, (2) whether the incidence of PMMA leakage is similar to that of Sr-HA leakage, and (3) whether Sr-HAis is resorbed and substituted by new vertebral bone. Materials and Methods. Two age- and sex-matched groups received short percutaneous pedicle screw fixation plus PEEK implant (Kiva, VCF Treatment System, Benvenue Medical, Santa Clara, CA, USA) filled with either Sr-HA (Group A) or PMMA (Group B) after A2- and A3/AO-type thoracolumbar vertebral body fractures. The Visual Analog Scale (VAS) score and imaging parameters, which included segmental kyphosis angle (SKA), vertebral body height ratios (VBHr), spinal canal encroachment (SCE), bone cement leakage, and Sr-HA resorption, were compared between the two groups. Results. The average follow-up was 28 months. No differences in VAS scores between Groups A and B were observed at baseline. Baseline back pain in both groups improved significantly three months postoperatively. Anterior, middle, and posterior VBHr did not differ between the two groups at any time point. SKA was improved insignificantly in both groups. SCE decreased insignificantly in both groups on 12-month follow-up using computed tomography (CT). PMMA leakage was observed in one patient, while no Sr-HA paste leakages occurred. Sr-HA resorption and replacement with vertebral bone were observed, and no new fractures were observed. Conclusions. As all hypotheses were confirmed, the authors recommend the use of Sr-HA instead of PMMA in traumatic spine fractures, although more patients and longer follow-up will be needed to strengthen these results. This trial is registered with NCT03431519.


2011 ◽  
Vol 15 (2) ◽  
pp. 146-150 ◽  
Author(s):  
Chang Ju Hwang ◽  
Choon-Ki Lee ◽  
Bong-Soon Chang ◽  
Min-Seok Kim ◽  
Jin S. Yeom ◽  
...  

Object The aim of this study was to evaluate after more than 5 years the outcome of surgical treatment for flexible idiopathic scoliosis using skipped pedicle screw fixation. Methods For patients with spine curves < 90° and flexibility > 20%, pedicle screws had been inserted into every other segment on the corrective side and 2–4 screws per curve had been inserted on the supportive side. The authors analyzed the results in 57 patients, including the correction rate of coronal curvature and rotational deformity, correction loss, sagittal balance, complications, blood loss, operation time, and implant costs. Results The mean Cobb angle was 54° preoperatively and 17° immediately after surgery (69% correction). At the last follow-up, the mean Cobb angle was 18° (2% correction loss). Rotation of the apical vertebra was corrected by 50% on average and showed only a 6% correction loss at the last follow-up. None of the patients had problems in maintaining sagittal balance. An adding-on phenomenon was detected in 4 patients (7%). Twelve of 14 patients with coronal decompensation showed improvement after surgery, whereas postoperative decompensation developed in 3 patients. Four patients had implant failures, and 4 had postoperative infections. The mean blood loss during surgery was 832 ml, and the mean operation time was 167 minutes. Compared with conventional methods, the authors' method used up to 48% fewer screws. Conclusions Skipped pedicle screw fixation of flexible idiopathic scoliosis showed satisfactory results. This method has several advantages, including reduced blood loss, shorter operation time, and reduced cost.


Sign in / Sign up

Export Citation Format

Share Document