scholarly journals Helical baffle design in shell and tube type heat exchanger with CFD analysis

2017 ◽  
Vol 35 (2) ◽  
pp. 378-383 ◽  
Author(s):  
Dipankar De ◽  
Tarun Pal ◽  
Santanu Bandyopadhyay
2021 ◽  
Vol 9 (4B) ◽  
Author(s):  
Devanand D. Chillal ◽  
◽  
Uday C. Kapale ◽  
N.R. Banapurmath ◽  
T. M. Yunus Khan ◽  
...  

The work presented is an effort to realize the changes occurring for convective coefficients of heat transfer in STHX fitted with inclined baffles. Effort has been undertaken using Fluent, a commercially available CFD code ona CAD model of small STHX with inclined baffles with cold liquid flowing into the tubes and hot liquid flowing in the shell. Four sets of CFD analysis have been carried out. The hot liquid flow rate through shell compartments varied from 0.2 kg/sec to 0.8 kg/sec in steps of 0.2 kg/sec, while keeping the cold liquid flow condition in tube at 0.4 kg/sec constant. Heat transfer rates, compartment temperatures, and overall heat transfer coefficients, for cold liquid and hot liquid, were studied. The results given by the software using CFD approach were appreciable and comparatively in agreement with the results available by the experimental work, which was undertaken for the same set of inlet pressure conditions, liquid flow rates, and inlet temperatures of liquid for both hot and cold liquids. The experimental output results were also used to validate the results given by the CFD software. The results from the CFD analysis were further used to conclude the effect of baffle inclination on heat duty. The process thus followed also helped realize the effects of baffle inclination on convective heat transfer coefficient of the liquid flow through the shell in an inclined baffle shell and tube heat exchanger. The temperature plots for both cold and hot liquid were also generated for understanding the compartmental temperature distributions inclusive of the inlet and outlet compartments. The heat duty for a heat exchanger has been found to increase with the increase in baffle inclinations from zero degree to 20 degrees. Likewise, the convective heat transfer coefficients have also been found to increase with the increase in baffle inclinations.


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Amarjit Singh ◽  
Satbir S. Sehgal

In this study, the experimental analysis was performed on the shell-and-tube type heat exchanger containing segmental baffles at different orientations. In the current work, three angular orientations (θ) 0°, 30°, and 60° of the baffles were analyzed for laminar flow having the Reynolds number range 303–1516. It was observed that, with increase of Reynolds number from 303 to 1516, there was a 94.8% increase in Nusselt number and 282.9% increase in pressure drop. Due to increase of Reynolds number from 303 to 1516, there is a decrease in nondimensional temperature factor for cold water (ω) by 57.7% and hot water (ξ) by 57.1%, respectively.


Author(s):  
Asep Bayu Dani Nandiyanto ◽  
◽  
Silmi Ridwan Putri ◽  
Risti Ragadhita ◽  
Rina Maryanti ◽  
...  

This study aims to analyze and develop a heat exchanger (HE) application for the manufacture of silica nanoparticles synthesis from agricultural waste. This shell and tube-type HE is designed simply, but it still refers to the existing design rules. The design of a shell and tube type HE with one pass shell and tube with turbulence flow. The specifications of the HE apparatus are 1.93 m in shell length, 0.203 m in shell diameter, 0.020 m in inner tube diameter, 0.022 m in outer tube diameter, and 0.016 m in thickness. The results showed an effectiveness value of 66.38% with an impurity factor of 0.01314. This informed that although the shell and tube-typed HE does not meet the requirements and standards for being set in industrial applications, it can be useful as a learning method regarding the design process, working mechanism, and analyzing the performance of the HE.


Sign in / Sign up

Export Citation Format

Share Document