scholarly journals Deploying a Planar Elastic Rod System with Cable Elements Attached to a Spacecraft

Author(s):  
С.В. Русских ◽  
Keyword(s):  
2017 ◽  
Author(s):  
Lucas Rafael Carneiro de Aguiar ◽  
José Roberto de França Arruda

2021 ◽  
Vol 2131 (3) ◽  
pp. 032086
Author(s):  
G Grebenuk ◽  
M Veshkin

Abstract An algorithm for calculating elastic rod systems under the action of impulse loads, using a complex model of internal friction in the material, has been developed and implemented in software. Very short (instantaneous) and extended in time impulses are considered as variants of impulse action. The importance of taking into account the vibration energy dissipation due to internal friction in the material of the structure is shown, considering impulse effects. The implemented software module is used to calculate the dynamic responses of the system in the search for the optimal solution of the control program for the selected variable parameters, target and restrictive functions. The problem of optimizing a flat frame system loaded with static and impulse loads has been posed and solved. An algorithm for finding an optimal solution is considered. Variants of dividing variable parameters into generalized groups are discussed. The minimum volume of material, spent on the structure, is taken as an optimality criterion. Analysis of the influence of the pulse duration of a given value on the calculation results without and with internal friction, as well as a comparative analysis of the optimal designs obtained without and with internal friction in the material and various tolerances for horizontal displacements. The results obtained indicate a significant effect of internal friction on the characteristics of the optimal design, especially with active movement restrictions.


Kerntechnik ◽  
2016 ◽  
Vol 81 (4) ◽  
pp. 445-451
Author(s):  
F. Čajko ◽  
M. Sečanský ◽  
T. Chrebet ◽  
R. Zajac ◽  
P. Dařílek

2020 ◽  
Vol 32 (3) ◽  
pp. 366-372
Author(s):  
Sandro M. Krieg ◽  
Nele Balser ◽  
Haiko Pape ◽  
Nico Sollmann ◽  
Lucia Albers ◽  
...  

OBJECTIVESemi-rigid instrumentation (SRI) was introduced to take advantage of the concept of load sharing in surgery for spinal stabilization. The authors investigated a topping-off technique in which interbody fusion is not performed in the uppermost motion segment, thus creating a smooth transition from stabilized to free motion segments. SRI using the topping-off technique also reduces the motion of the adjacent segments, which may reduce the risk of adjacent segment disease (ASD), a frequently observed sequela of instrumentation and fusion, but this technique may also increase the possibility of screw loosening (SL). In the present study the authors aimed to systematically evaluate reoperation rates, clinical outcomes, and potential risk factors and incidences of ASD and SL for this novel approach.METHODSThe authors collected data for the first 322 patients enrolled at their institution from 2009 to 2015 who underwent surgery performed using the topping-off technique. Reoperation rates, patient satisfaction, and other outcome measures were evaluated. All patients underwent pedicle screw–based semi-rigid stabilization of the lumbar spine with a polyetheretherketone (PEEK) rod system.RESULTSImplantation of PEEK rods during revision surgery was performed in 59.9% of patients. A median of 3 motion segments (range 1–5 segments) were included and a median of 2 motion segments (range 0–4 segments) were fused. A total of 89.4% of patients underwent fusion, 73.3% by transforaminal lumbar interbody fusion (TLIF), 18.4% by anterior lumbar interbody fusion (ALIF), 3.1% by extreme lateral interbody fusion (XLIF), 0.3% by oblique lumbar interbody fusion (OLIF), and 4.9% by combined approaches in the same surgery. Combined radicular and lumbar pain according to a visual analog scale was reduced from 7.9 ± 1.0 to 4.0 ± 3.1, with 56.2% of patients indicating benefit from surgery. After maximum follow-up (4.3 ± 1.8 years), the reoperation rate was 16.4%.CONCLUSIONSThe PEEK rod concept including the topping-off principle seems safe, with at least average patient satisfaction in this patient group. Considering the low rate of first-tier surgeries, the presented results seem at least comparable to those of most other series. Follow-up studies are needed to determine long-term outcomes, particularly with respect to ASD, which might be reduced by the presented approach.


2021 ◽  
Vol 1902 (1) ◽  
pp. 012014
Author(s):  
O U Kopteltseva ◽  
A A Markin
Keyword(s):  

2021 ◽  
Author(s):  
Mandar Deepak Borde ◽  
Sarang Sapare ◽  
Emile Schutgens ◽  
Chadi Ali ◽  
Hilali Noordeen

Abstract Study design A cross-sectional retrospective Level 3 study. Objective To study the serum levels of Titanium and Aluminium ions in patients operated using the magnetically controlled growing rod (MCGR) system. Summary of background data 14 consecutive patients of early onset scoliosis with varying etiology managed with MCGR system with a minimum follow-up of 24 months were selected for the study. The group consisted of two boys (14.3%) and 12 girls (85.7%). The average age of the patients at the time of surgery was 10.4 years (5–15 years). The average period of follow-up was 43.7 months (28–79 months). After informed consent of the subjects and their caretakers, serum levels of titanium and aluminium were measured. These levels were then assessed with regards to the number of screws used, number of distractions and complications. Methods The concentration of titanium and aluminium ions in the serum was measured using high resolution inductively coupled plasma mass spectrometry. Results For the sake of ease of assessment, patients were divided into three etiology-based groups—idiopathic (n = 6), neuromuscular (n = 2) and syndromic (n = 6). The mean serum titanium level was 15.9 μg/L (5.1–28.2 μg/L) while that of aluminium was 0.1 μmol/L (0.1–0.2 μmol/L). Of the 14 patients, 2 (14.2%) patients had mechanical failure (actuator pin dysfunction), 3 (21.4%) had rod breakage requiring revision surgery and one patient (7.1%) had surgical site infection managed with appropriate antibiotics. Patients undergoing revision for rod breakage did not show any metallosis of the tissues during surgery. Conclusion Analysis of patients with scoliosis operated using the magnetic growing rod system concludes that it is accompanied by presence of titanium in the blood but whether clinically significant or not needs to be ascertained by comparison of preoperative and postoperative blood concentrations of the titanium ions in individual subjects. The aluminium ion concentration remains within normal limits. Though implant malfunction may raise the titanium levels in the blood, its clinical significance needs to be determined. The aluminium levels are not affected irrespective to the presence or absence of complications. The long-term effects of raised titanium levels in the blood also warrant further prospective studies designed for precise and deeper analyses.


2021 ◽  
Vol 32 ◽  
pp. 100428
Author(s):  
Deniz Sirinoglu ◽  
Buse Sarigul ◽  
Onur Derdiyok ◽  
Ozan Baskurt ◽  
Mehmet Volkan Aydin

Sign in / Sign up

Export Citation Format

Share Document