Effects of Tourniquet Use on Blood Loss and Soft-Tissue Damage in Total Knee Arthroplasty

2012 ◽  
Vol 94 (24) ◽  
pp. 2209-2215 ◽  
Author(s):  
Ta-Wei Tai ◽  
Chih-Wei Chang ◽  
Kuo-An Lai ◽  
Chii-Jeng Lin ◽  
Chyun-Yu Yang
2020 ◽  
Vol 102-B (10) ◽  
pp. 1324-1330
Author(s):  
Stijn Herregodts ◽  
Mathijs Verhaeghe ◽  
Rico Paridaens ◽  
Jan Herregodts ◽  
Hannes Vermue ◽  
...  

Aims Inadvertent soft tissue damage caused by the oscillating saw during total knee arthroplasty (TKA) occurs when the sawblade passes beyond the bony boundaries into the soft tissue. The primary objective of this study is to assess the risk of inadvertent soft tissue damage during jig-based TKA by evaluating the excursion of the oscillating saw past the bony boundaries. The second objective is the investigation of the relation between this excursion and the surgeon’s experience level. Methods A conventional jig-based TKA procedure with medial parapatellar approach was performed on 12 cadaveric knees by three experienced surgeons and three residents. During the proximal tibial resection, the motion of the oscillating saw with respect to the tibia was recorded. The distance of the outer point of this cutting portion to the edge of the bone was defined as the excursion of the oscillating saw. The excursion of the sawblade was evaluated in six zones containing the following structures: medial collateral ligament (MCL), posteromedial corner (PMC), iliotibial band (ITB), lateral collateral ligament (LCL), popliteus tendon (PopT), and neurovascular bundle (NVB). Results The mean 75th percentile value of the excursion of all cases was mean 2.8 mm (SD 2.9) for the MCL zone, mean 4.8 mm (SD 5.9) for the PMC zone, mean 3.4 mm (SD 2.0) for the ITB zone, mean 6.3 mm (SD 4.8) for the LCL zone, mean 4.9 mm (SD 5.7) for the PopT zone, and mean 6.1 mm (SD 3.9) for the NVB zone. Experienced surgeons had a significantly lower excursion than residents. Conclusion This study showed that the oscillating saw significantly passes the edge of the bone during the tibial resection in TKA, even in experienced hands. While reported neurovascular complications in TKA are rare, direct injury to the capsule and stabilizing structures around the knee is a consequence of the use of a hand-held oscillating saw when making the tibial cut. Cite this article: Bone Joint J 2020;102-B(10):1324–1330.


2019 ◽  
Vol 8 (10) ◽  
pp. 495-501 ◽  
Author(s):  
Emily L. Hampp ◽  
Nipun Sodhi ◽  
Laura Scholl ◽  
Matthew E. Deren ◽  
Zachary Yenna ◽  
...  

Objectives The use of the haptically bounded saw blades in robotic-assisted total knee arthroplasty (RTKA) can potentially help to limit surrounding soft-tissue injuries. However, there are limited data characterizing these injuries for cruciate-retaining (CR) TKA with the use of this technique. The objective of this cadaver study was to compare the extent of soft-tissue damage sustained through a robotic-assisted, haptically guided TKA (RATKA) versus a manual TKA (MTKA) approach. Methods A total of 12 fresh-frozen pelvis-to-toe cadaver specimens were included. Four surgeons each prepared three RATKA and three MTKA specimens for cruciate-retaining TKAs. A RATKA was performed on one knee and a MTKA on the other. Postoperatively, two additional surgeons assessed and graded damage to 14 key anatomical structures in a blinded manner. Kruskal–Wallis hypothesis tests were performed to assess statistical differences in soft-tissue damage between RATKA and MTKA cases. Results Significantly less damage occurred to the PCLs in the RATKA versus the MTKA specimens (p < 0.001). RATKA specimens had non-significantly less damage to the deep medial collateral ligaments (p = 0.149), iliotibial bands (p = 0.580), poplitei (p = 0.248), and patellar ligaments (p = 0.317). The remaining anatomical structures had minimal soft-tissue damage in all MTKA and RATKA specimens. Conclusion The results of this study indicate that less soft-tissue damage may occur when utilizing RATKA compared with MTKA. These findings are likely due to the enhanced preoperative planning with the robotic software, the real-time intraoperative feedback, and the haptically bounded saw blade, all of which may help protect the surrounding soft tissues and ligaments. Cite this article: Bone Joint Res 2019;8:495–501. DOI: 10.1302/2046-3758.810.BJR-2019-0129.R1.


2017 ◽  
Vol 14 (3) ◽  
pp. 347-353 ◽  
Author(s):  
Constantin Mayer ◽  
Alexander Franz ◽  
Jan-Frieder Harmsen ◽  
Fina Queitsch ◽  
Michael Behringer ◽  
...  

10.29007/v7g9 ◽  
2019 ◽  
Author(s):  
Emily Hampp ◽  
Nipun Sodhi ◽  
Laura Scholl ◽  
Matthew Deren ◽  
Zachary Yenna ◽  
...  

While manual total knee arthroplasty (MTKA) has demonstrated excellent clinical results, occasionally intraoperative damage to soft tissues can occur. Robotic-arm assisted technology is designed to constrain a sawblade in a haptic zone to help ensure that only the desired bone cuts are made. The objective of this cadaver study was to quantify the extent of soft tissue damage sustained during TKA through a robotic-arm assisted (RATKA) haptically guided approach and conventional MTKA approach. Four surgeons each prepared 3 RATKA and 3 MTKA specimens for cruciate retaining TKAs. RATKA was performed on one knee, with MTKA on the other. Postoperatively, 2 additional blinded surgeons, assessed and graded damage to 14 key anatomic structures. A Kruskal-Wallis hypothesis test was performed to assess for statistical differences of soft tissue damages between RATKA and MTKA cases. A p-value &lt;0.05 was used as the threshold for statistical significance, and p-values were adjusted for ties. Significantly less damage occurred to the PCL in the RATKA than the MTKA specimens (p&lt;0.0001). RATKA specimens had less damage to the dMCL (p=.149), ITB (p=0.580), popliteus (p=0.248), and patellar ligament (p=0.317). The results of this study indicate that RATKA may result in less soft-tissue damage than MTKA, especially to the PCL.


10.29007/vbqh ◽  
2019 ◽  
Author(s):  
Raga Rajaravivarma ◽  
Sally Liarno ◽  
Tatyana Kaverina ◽  
Sonia Donde ◽  
Emily Sneddon

The use of haptic-based robotic-arm assisted total knee arthroplasty (hRATKA) has demonstrated a decrease in soft tissue damage. Hampp et al. [4] compared the soft tissue damage in a cadaveric study between manual total knee arthroplasty (MTKA) and hRATKA and found that the hRATKA specimens had significantly less damage to the PCL than the MTKA specimens [4]. The purpose of this study is to look at the effect of the posterior cruciate ligament (PCL) on kinematics, as defined by anterior-posterior (AP) tibial translation, during stair climb. Using a 6 degree-of-freedom (6-DOF) joint motion simulator, the stair climb profile was run on four cadaveric knee specimens with the PCL intact and the PCL cut. In the PCL deficient condition, there was more posterior tibial motion than when the PCL was intact, and this was more noticeable during the high flexion portion of the profile. These findings speak to the importance of soft tissue preservation, and the development of haptic-based robotic-arm assisted TKA can help prevent soft tissue damage to the PCL.


Author(s):  
Meredith Perkins ◽  
Julie Lowell ◽  
Christina Arnholt ◽  
Daniel MacDonald ◽  
Anita L. Kerkhof ◽  
...  

2021 ◽  
Vol 29 (1) ◽  
pp. 230949902110020
Author(s):  
Seikai Toyooka ◽  
Hironari Masuda ◽  
Nobuhiro Nishihara ◽  
Takashi Kobayashi ◽  
Wataru Miyamoto ◽  
...  

Purpose: To evaluate the integrity of lateral soft tissue in varus osteoarthritis knee by comparing the mechanical axis under varus stress during navigation-assisted total knee arthroplasty before and after compensating for a bone defect with the implant. Methods: Sixty-six knees that underwent total knee arthroplasty were investigated. The mechanical axis of the operated knee was evaluated under manual varus stress immediately after knee exposure and after navigation-assisted implantation. The correlation between each value of the mechanical axis and degree of preoperative varus deformity was compared by regression analysis. Results: The maximum mechanical axis under varus stress immediately after knee exposure increased in proportion to the degree of preoperative varus deformity. Moreover, the maximum mechanical axis under varus stress after implantation increased in proportion to the degree of preoperative varus deformity. Therefore, the severity of varus knee deformity leads to a progressive laxity of the lateral soft tissue. However, regression coefficients after implantation were much smaller than those measured immediately after knee exposure (0.99 vs 0.20). Based on the results of the regression formula, the postoperative laxity of the lateral soft tissue was negligible, provided that an appropriate thickness of the implant was compensated for the bone and cartilage defect in the medial compartment without changing the joint line. Conclusion: The severity of varus knee deformity leads to a progressive laxity of the lateral soft tissue. However, even if the degree of preoperative varus deformity is severe, most cases may not require additional procedures to address the residual lateral laxity.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Ran Zhao ◽  
Yanqing Liu ◽  
Hua Tian

Abstract Background Soft tissue balancing is essential for the success of total knee arthroplasty (TKA) and is mainly dependent on surgeon-defined assessment (SDA) or a gap-balancer (GB). However, an electronic sensor has been developed to objectively measure the gap pressure. This study aimed to evaluate the accuracy of soft tissue balancing using SDA and GB compared with a sensor. Methods Forty-eight patients undergoing TKA (60 knees) were prospectively enrolled. Soft tissue balancing was sequentially performed using SDA, a GB, and an electronic sensor. We compared the SDA, GB, and sensor data to calculate the sensitivity, specificity, and accuracy at 0°, 45°, 90°, and 120° flexion. Cumulative summation (CUSUM) analysis was performed to assess the surgeon’s performance during the sensor introductory phase. Results The sensitivity of SDA was 63.3%, 68.3%, 80.0%, and 80.0% at 0°, 45°, 90°, and 120°, respectively. The accuracy of the GB compared with sensor data was 76.7% and 71.7% at 0° and 90°, respectively. Cohen’s kappa coefficient for the accuracy of the GB was 0.406 at 0° (moderate agreement) and 0.227 at 90° (fair agreement). The CUSUM 0° line achieved good prior performance at case 45, CUSUM 90° and 120° showed a trend toward good prior performance, while CUSUM 45° reached poor prior performance at case 8. Conclusion SDA was a poor predictor of knee balance. GB improved the accuracy of soft tissue balancing, but was still less accurate than the sensor, particularly for unbalanced knees. SDA improved with ongoing use of the sensor, except at 45° flexion.