scholarly journals An alternative method of chest compression from over-the-head during cardiopulmonary resuscitation

2019 ◽  
Author(s):  
Michał Ćwiertnia ◽  
Marek Kawecki ◽  
Tomasz Ilczak ◽  
Monika Mikulska ◽  
Mieczyslaw Dutka ◽  
...  

Abstract Background Maintaining highly effective cardiopulmonary resuscitation (CPR) can be particularly difficult when artificial respiration using a bag-valve-mask device, combined with chest compression have to be carried out by one person. The aim of the study is to compare the quality of CPR conducted by one paramedic using chest compression from the patient’s side, with compression carried out from behind the patient’s head. Methods The subject of the study were two methods of CPR – ‘standard’ (STD) and ‘over-the-head’ (OTH). The STD method consisted of 30 chest compressions from the patient’s side, and two attempts at artificial respiration after moving round to behind the patient’s head. In the OTH method, both compression and respiration were conducted from behind the patient’s head. Results Both CPR methods were conducted by 38 paramedics working in medical response teams. The average time of the interruptions between compression cycles (STD 9.184 s, OTH 7.316 s, p<0.001); the depth of compression 50–60 mm (STD 50.65%, OTH 60.22%, p<0.001); the rate of compression 100–120/min. (STD 46.39%, OTH 53.78%, p<0.001); complete chest wall recoil (STD 84.54%, OTH 91.46%, p<0.001); correct hand position (STD 99.32%, OTH method 99.66%, p<0.001). The remaining parameters showed no significant differences in comparison to reference values. Conclusions The demonstrated higher quality of CPR in the simulated research using the OTH method conducted by one person justifies the use of this method in a wider range of emergency interventions than only for CPR conducted in confined spaces.

2019 ◽  
Author(s):  
Michał Ćwiertnia ◽  
Marek Kawecki ◽  
Tomasz Ilczak ◽  
Monika Mikulska ◽  
Mieczysław Dutka ◽  
...  

Abstract Background: Maintaining highly effective cardiopulmonary resuscitation (CPR) can be particularly difficult when artificial ventilation using a bag-valve-mask device, combined with chest compression have to be carried out by one person. The aim of the study is to compare the quality of CPR conducted by one paramedic using chest compression from the patient’s side with compression conducted from the ‘over-the-head’ position. Methods: The subject of the study were two methods of CPR – ‘standard’ (STD) and ‘over-the-head’ (OTH). The STD method consisted of cycles of 30 chest compressions from the patient’s side, and two attempts at artificial ventilation after moving round to behind the patient’s head. In the OTH method, both compression and ventilation were conducted from behind the patient’s head. Results: Both CPR methods were conducted by 38 paramedics working in medical response teams. Statistical analysis was conducted on the data collected, giving the following results: the average time of the interruptions between compression cycles (STD 9.184 s, OTH 7.316 s, p < 0.001); the depth of compression 50–60 mm (STD 50.65%, OTH 60.22%, p < 0.001); the rate of compression 100–120/min. (STD 46.39%, OTH 53.78%, p < 0.001); complete chest wall recoil (STD 84.54%, OTH 91.46%, p < 0.001); correct hand position (STD 99.32%, OTH method 99.66%, p < 0.001). A statistically significant difference was demonstrated in the results to the benefit of the OTH method in the above parameters. The remaining parameters showed no significant differences in comparison to reference values. Conclusions: The demonstrated higher quality of CPR in the simulated research using the OTH method conducted by one person justifies the use of this method in a wider range of emergency interventions than only for CPR conducted in confined spaces.


2019 ◽  
Author(s):  
Michał Ćwiertnia ◽  
Marek Kawecki ◽  
Tomasz Ilczak ◽  
Monika Mikulska ◽  
Mieczysław Dutka ◽  
...  

Abstract Background: Maintaining highly effective cardiopulmonary resuscitation (CPR) can be particularly difficult when artificial ventilation using a bag-valve-mask device, combined with chest compression have to be carried out by one person. The aim of the study is to compare the quality of CPR conducted by one paramedic using chest compression from the patient’s side with compression conducted from the ‘over-the-head’ position. Methods: The subject of the study were two methods of CPR – ‘standard’ (STD) and ‘over-the-head’ (OTH). The STD method consisted of cycles of 30 chest compressions from the patient’s side, and two attempts at artificial ventilation after moving round to behind the patient’s head. In the OTH method, both compressions and ventilations were conducted from behind the patient’s head. Results: Both CPR methods were conducted by 38 paramedics working in medical response teams. Statistical analysis was conducted on the data collected, giving the following results: the average time of the interruptions between compression cycles (STD 9.184 s, OTH 7.316 s, p < 0.001); the depth of compression 50–60 mm (STD 50.65%, OTH 60.22%, p < 0.001); the rate of compression 100–120/min. (STD 46.39%, OTH 53.78%, p < 0.001); complete chest wall recoil (STD 84.54%, OTH 91.46%, p < 0.001); correct hand position (STD 99.32%, OTH method 99.66%, p < 0.001). A statistically significant difference was demonstrated in the results to the benefit of the OTH method in the above parameters. The remaining parameters showed no significant differences in comparison to reference values. Conclusions: The higher quality of CPR in the simulated research using the OTH method by a single person justifies the use of this method in a wider range of emergency interventions.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Michał Ćwiertnia ◽  
Marek Kawecki ◽  
Tomasz Ilczak ◽  
Monika Mikulska ◽  
Mieczysław Dutka ◽  
...  

Abstract Background Maintaining highly effective cardiopulmonary resuscitation (CPR) can be particularly difficult when artificial ventilation using a bag-valve-mask device, combined with chest compression have to be carried out by one person. The aim of the study is to compare the quality of CPR conducted by one paramedic using chest compression from the patient’s side with compression conducted from the ‘over-the-head’ position. Methods The subject of the study were two methods of CPR – ‘standard’ (STD) and ‘over-the-head’ (OTH). The STD method consisted of cycles of 30 chest compressions from the patient’s side, and two attempts at artificial ventilation after moving round to behind the patient’s head. In the OTH method, both compressions and ventilations were conducted from behind the patient’s head. Results Both CPR methods were conducted by 38 paramedics working in medical response teams. Statistical analysis was conducted on the data collected, giving the following results: the average time of the interruptions between compression cycles (STD 9.184 s, OTH 7.316 s, p < 0.001); the depth of compression 50–60 mm (STD 50.65%, OTH 60.22%, p < 0.001); the rate of compression 100–120/min. (STD 46.39%, OTH 53.78%, p < 0.001); complete chest wall recoil (STD 84.54%, OTH 91.46%, p < 0.001); correct hand position (STD 99.32%, OTH method 99.66%, p < 0.001). A statistically significant difference was demonstrated in the results to the benefit of the OTH method in the above parameters. The remaining parameters showed no significant differences in comparison to reference values. Conclusions The higher quality of CPR in the simulated research using the OTH method by a single person justifies the use of this method in a wider range of emergency interventions.


2019 ◽  
Author(s):  
Michał Ćwiertnia ◽  
Marek Kawecki ◽  
Tomasz Ilczak ◽  
Monika Mikulska ◽  
Mieczysław Dutka ◽  
...  

Abstract Background: Maintaining highly effective cardiopulmonary resuscitation (CPR) can be particularly difficult when artificial ventilation using a bag-valve-mask device, combined with chest compression have to be carried out by one person. The aim of the study is to compare the quality of CPR conducted by one paramedic using chest compression from the patient’s side with compression conducted from the ‘over-the-head’ position. Methods: The subject of the study were two methods of CPR – ‘standard’ (STD) and ‘over-the-head’ (OTH). The STD method consisted of cycles of 30 chest compressions from the patient’s side, and two attempts at artificial ventilation after moving round to behind the patient’s head. In the OTH method, both compressions and ventilations were conducted from behind the patient’s head. Results: Both CPR methods were conducted by 38 paramedics working in medical response teams. Statistical analysis was conducted on the data collected, giving the following results: the average time of the interruptions between compression cycles (STD 9.184 s, OTH 7.316 s, p < 0.001); the depth of compression 50–60 mm (STD 50.65%, OTH 60.22%, p < 0.001); the rate of compression 100–120/min. (STD 46.39%, OTH 53.78%, p < 0.001); complete chest wall recoil (STD 84.54%, OTH 91.46%, p < 0.001); correct hand position (STD 99.32%, OTH method 99.66%, p < 0.001). A statistically significant difference was demonstrated in the results to the benefit of the OTH method in the above parameters. The remaining parameters showed no significant differences in comparison to reference values. Conclusions: The higher quality of CPR in the simulated research using the OTH method by a single person justifies the use of this method in a wider range of emergency interventions.


2014 ◽  
Vol 21 (6) ◽  
pp. 382-386 ◽  
Author(s):  
Ch Jo ◽  
Jh Ahn ◽  
Yd Shon ◽  
Gc Cho

Introduction The aim of this study was to determine the effect of hand positioning on the quality of external chest compression (ECC) by novice rescuers. Methods This observational simulation study was conducted for 117 included participants. After completion of an adult cardiopulmonary resuscitation (CPR) training program for 3-h, the participants selected which of their hands would be in contact with the mannequin during ECC and performed 5 cycles of single rescuer CPR on a recording mannequin. The participants were assigned to 2 groups: the dominant hand group (DH; n=40) and the non-dominant hand group (NH; n=29). The depth and rate of ECC were analysed to compare the effectiveness of ECC between 2 groups. Results The rate of ECC was significantly faster in the DH group (mean, 117.3 ±11.4/min) than in the NH group (mean, 110.9±12.2/min) (p=0.028). However, the depth of ECC in the dominant hand group (mean, 52.4±5.9 mm) was not significantly different from that in the non-dominant hand group (mean, 50.8±6.0 mm) (p=0.287). Similarly, the portion of ECC with inadequate depth in the dominant hand group (mean, 1.8±4.3%) was not significantly different from that in the non-dominant hand group (mean, 5.3±15.6%) (p=0.252). Conclusions ECC can be performed with an acceptably higher rate of compressions when the dominant hand of the novice rescuer is placed in contact with the sternum. However, the position of the dominant hand does not affect the depth of ECC. (Hong Kong j.emerg.med. 2014;21:382-386)


Author(s):  
Giani Cioccari ◽  
Tais Sica da Rocha ◽  
Jefferson Pedro Piva

Background To compare the 2‐finger and 2‐thumb chest compression techniques on infant manikins in an out‐of‐hospital setting regarding efficiency of compressions, ventilation, and rescuer pain and fatigue. Methods and Results In a randomized crossover design, 78 medical students performed 2 minutes of cardiopulmonary resuscitation with mouth‐to‐nose ventilation at a 30:2 rate on a Resusci Baby QCPR infant manikin (Laerdal, Stavanger, Norway), using a barrier device and the 2‐finger and 2‐thumb compression techniques. Frequency and depth of chest compressions, proper hand position, complete chest recoil at each compression, hands‐off time, tidal volume, and number of ventilations were evaluated through manikin‐embedded SkillReporting software. After the interventions, standard Likert questionnaires and analog scales for pain and fatigue were applied. The variables were compared by a paired t ‐test or Wilcoxon test as suitable. Seventy‐eight students participated in the study and performed 156 complete interventions. The 2‐thumb technique resulted in a greater depth of chest compressions (42 versus 39.7 mm; P <0.01), and a higher percentage of chest compressions with adequate depth (89.5% versus 77%; P <0.01). There were no differences in ventilatory parameters or hands‐off time between techniques. Pain and fatigue scores were higher for the 2‐finger technique (5.2 versus 1.8 and 3.8 versus 2.6, respectively; P <0.01). Conclusions In a simulation of out‐of‐hospital, single‐rescuer infant cardiopulmonary resuscitation, the 2‐thumb technique achieves better quality of chest compressions without interfering with ventilation and causes less rescuer pain and fatigue.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Shunsuke Yamanaka ◽  
Kei Nishiyama ◽  
Hiroyuki Hayashi ◽  
Ji Young Huh

Background: Effective chest compression (CC) is vital in cardiopulmonary resuscitation (CPR), and rescuer’s fatigue negatively affects quality of CPR. However, there is no consensus on the appropriate number of personnel needed for CC to avoid rescuer’s fatigue. Objective: We determined the appropriate number of personnel needed for 30-min CPR in a rescue-team in a hospital. Methods: We conducted a preliminary randomized, crossover, manikin trial on healthcare providers. We divided them into Groups A to D according to the intervals between the 2-min CC and assigned a different interval to each group. Groups A, B, C, and D performed CCs at 2-, 4-, 6-, and 8-min intervals as in 2, 3, 4, and 5 personnel, respectively. All participants performed CCs for 30 min with different intervals depending on the assigned group; participants allocated to Groups A, B, C, and D performed 8, 5, 4, and 3 cycles, respectively. We compared the differences between first cycle and the second to the last cycle Results: We enrolled 42 participants (age: 25.2±4.2, men 47.6%) for the preliminary evaluation. We used Kruskal-Wallis for the analysis. Participants in the less interval Groups A and B performed faster (A: -24.28±15.18, B: -7.90±13.49, C: -11.27±17.01, D: -2.38±3.31, P=0.03) and shallower CCs (A: -4.42±6.92, B: -3.18±5.43, C: -0.18±5.74, D: -1.23±4.10, P=0.62). Women-rescuers performed faster (A: -27.25±12.23, B: -7.00±13.97, C: -8.16±19.26, D: 3.16±4.66, P= 0.05) and shallower CCs (A: -6.25±7.54, B: -3.00±6.89, C: -3.66±3.32, D: -0.16±4.35, P=0.58). However, CCs of men-rescuers were not faster (A: -20.33±20.65, B: -9.00±14.44, C: -15.00±15.11, D: -7.14±16.70, P= 0.60) or shallower (A: -2.00±6.55 B: -3.40±3.78, C: 4.00±5.33, D: -2.14±3.98, P=0.06). Conclusion: At least four rescuers (Group C) may be needed to reduce rescuer’s fatigue for 30-min CPR. If the team only includes women, more personnel would be needed as women experience fatigue faster.


Circulation ◽  
2014 ◽  
Vol 130 (suppl_2) ◽  
Author(s):  
Chika Nishiyama ◽  
Tetsuhisa Kitamura ◽  
Tomonari Shimamoto ◽  
Takashi Kawamura ◽  
Tetsuya Sakamoto ◽  
...  

Introduction: Although quality of cardiopulmonary resuscitation (CPR) is a key to increase survival after out-of-hospital cardiac arrest (OHCA), little is known about the quality of bystander CPR and its association with survival outcomes after OHCA. Objective: To evaluate the association of quality of bystander CPR and patient outcomes after OHCA. Methods: Designs: Population-based cohort study. Cases: All OHCA cases treated by emergency medical services (EMS) personnel in Toyonaka city between September 2011 and August 2013. Data collection and analyses: EMS personnel assessed bystanders’ CPR quality including hand position, depth, and tempo of chest compressions using a specific data form at the scene. Fleiss’ Kappa statistics was used to assess the evaluation reliability among EMS personnel and the Kappa value was 0.81 before the study. The primary outcome was patient one-month survival with favorable neurological outcome and it was compared between the good-quality CPR group and the poor-quality CPR group. Results: Among 877 cases, bystander CPR was attempted in 429 (48.9%). Data on quality of CPR was applicable in 272 (63.4%) of them. In the good-quality CPR group, bystanders were younger, more likely to be health care provider, and have experience of CPR training than in the poor-quality of CPR group. The proportion of patients with neurologically favorable one-month survival was somewhat greater in the good-quality of CPR group (4.6% versus 3.0%), although it was statistically insignificant. Conclusions: Better quality of bystander chest compressions might increase OHCA patient survival. Further efforts to improve quality of CPR by general public are needed.


Sign in / Sign up

Export Citation Format

Share Document