Study on Gas Leakage Detection and Pressure Difference Identification by Asymmetric Differential Pressure Method
Abstract As the most common actuator in the pneumatic system, the excellent air tightness of the tank is the key to meet the use requirements of automatic equipment. This paper introduces the common air tightness detection contents, and models the inflation and detection process of the differential pressure method. In order to break away from the restriction on the detection efficiency caused by the asynchronous temperature recovery of the two chambers in the asymmetric differential pressure method, the differential calculation of directly detected pressure difference is replaced by the pressure difference substitute formula. The influence of various parameters in the fitting formula is analyzed by simulation, and the effectiveness of this method is verified by experiments.