scholarly journals Development of Monoclonal Antibody Based IgG and IgM ELISA for Diagnosis of Severe Fever with Thrombocytopenia Syndrome Virus Infection

Author(s):  
Mei Zhang ◽  
Yanhua Du ◽  
Li Yang ◽  
Lin Zhan ◽  
Bin Yang ◽  
...  

Abstract Background: Severe fever with thrombocytopenia syndrome virus (SFTSV) is a newly emerged virus that possesses a great threat to human health because of the high fatality rate. Method: To develop sensitive and specific sero-diagnosis systems for SFTSV infections, monoclonal antibodies (MAbs) against recombinant SFTSV nucleocapsid (rSFTSV-N) protein were developed by immunizing BALB/C mice with rSFTSV-N protein and fusing the spleen cells with SP2/0 myeloma cells. Three hybridoma cell lines secreting MAbs against rSFTSV-N were obtained. MAb based IgG sandwich enzyme linked immunosorbent assay (ELISA) and IgM capture ELISA systems were established by using the newly developed MAbs. One hundred fifteen clinical suspected SFTS patient serum samples were used to evaluate the newly established systems by comparing with the total antibody detecting sandwich ELISA system and indirect ELISA systems. Results: The MAb based sandwich IgG ELISA was perfectly matched with that of the total antibody sandwich ELISA and the indirect IgG ELISA with a sensitivity and specificity of 100%. IgM capture ELISA results perfectly matched with that of the total antibody sandwich ELISA while was more sensitive comparing with the indirect IgM ELISA. Conclusions: The MAbs against rSFTSV-N protein offer new tools for SFTSV studies and our newly developed MAb-based IgG and IgM capture ELISA systems would offer safe and useful tools for diagnosis of SFTS virus infections and epidemiological investigations.

2005 ◽  
Vol 12 (1) ◽  
pp. 135-140 ◽  
Author(s):  
Biao Di ◽  
Wei Hao ◽  
Yang Gao ◽  
Ming Wang ◽  
Ya-di Wang ◽  
...  

ABSTRACT Accurate and timely diagnosis of severe acute respiratory syndrome coronavirus (SARS-CoV) infection is a critical step in preventing another global outbreak. In this study, 829 serum specimens were collected from 643 patients initially reported to be infected with SARS-CoV. The sera were tested for the N protein of SARS-CoV by using an antigen capture enzyme-linked immunosorbent assay (ELISA) based on monoclonal antibodies against the N protein of SARS-CoV and compared to 197 control serum samples from healthy donors and non-SARS febrile patients. The results of the N protein detection analysis were directly related to the serological analysis data. From 27 SARS patients who tested positive with the neutralization test, 100% of the 24 sera collected from 1 to 10 days after the onset of symptoms were positive for the N protein. N protein was not detected beyond day 11 in this group. The positive rates of N protein for sera collected at 1 to 5, 6 to 10, 11 to 15, and 16 to 20 days after the onset of symptoms for 414 samples from 298 serologically confirmed patients were 92.9, 69.8, 36.4, and 21.1%, respectively. For 294 sera from 248 serological test-negative patients, the rates were 25.6, 16.7, 9.3, and 0%, respectively. The N protein was not detected in 66 patients with cases of what was initially suspected to be SARS but serologically proven to be negative for SARS and in 197 serum samples from healthy donors and non-SARS febrile patients. The specificity of the assay was 100%. Furthermore, of 16 sera collected from four patients during the SARS recurrence in Guangzhou, 5 sera collected from 7 to 9 days after the onset of symptoms were positive for the N protein. N protein detection exhibited a high positive rate, 96 to 100%, between day 3 and day 5 after the onset of symptoms for 27 neutralization test-positive SARS patients and 298 serologically confirmed patients. The N protein detection rate continually decreased beginning with day 10, and N protein was not detected beyond day 19 after the onset of symptoms. In conclusion, an antigen capture ELISA reveals a high N protein detection rate in acute-phase sera of patients with SARS, which makes it useful for early diagnosis of SARS.


2005 ◽  
Vol 12 (10) ◽  
pp. 1235-1237 ◽  
Author(s):  
M. Nawa ◽  
T. Takasaki ◽  
M. Ito ◽  
S. Inoue ◽  
K. Morita ◽  
...  

ABSTRACT We determined the usefulness of an immunoglobulin A (IgA) antibody-capture enzyme-linked immunosorbent assay for serodiagnosis of dengue virus infections. The results indicate that the presence of IgA and IgM in serum samples assures recent primary dengue virus infection even with a single serum sample.


2003 ◽  
Vol 10 (3) ◽  
pp. 439-442 ◽  
Author(s):  
F. Roodbari ◽  
M. H. Roustai ◽  
A. Mostafaie ◽  
H. Soleimanjdahi ◽  
R. Sarrami Foroshani ◽  
...  

ABSTRACT Measles is a highly contagious respiratory virus infection, with typical clinical symptoms including maculopapular rash, fever, cough, coryza, and conjunctivitis. Despite implementation of widespread vaccination programs throughout the world, the rates of global morbidity and mortality are still considerable. This study was performed to design a reliable indirect enzyme-linked immunosorbent assay (ELISA) to measure measles-specific immunoglobulin M (IgM). First, human IgM was purified, and then an anti-IgM antibody was produced in rabbits and purified in a multistep process. The rabbit IgG against human IgM was conjugated with peroxidase. Measles virus-infected Vero cells produced viral antigen. One hundred serum samples from infants of 9 to 18 months of age, mostly vaccinated, were evaluated for determining the presence of specific IgM antibodies against measles virus. The samples were also evaluated for neutralizing antibodies against measles virus by a microneutralization test (MNT). By comparing the results of the ELISA with those of MNT, it was demonstrated that ELISA had a sensitivity and specificity of 100 and 92%, respectively. On the other hand, when the results obtained by our ELISA system were compared with those of an imported measles virus IgM ELISA kit (EIAgen; Adaltis Italia SPa, Bologna, Italy), a high level of agreement was shown (k = 0.926).


2007 ◽  
Vol 14 (9) ◽  
pp. 1182-1189 ◽  
Author(s):  
Masayuki Saijo ◽  
Marie-Claude Georges-Courbot ◽  
Philippe Marianneau ◽  
Victor Romanowski ◽  
Shuetsu Fukushi ◽  
...  

ABSTRACT Diagnostic systems for Lassa fever (LF), a viral hemorrhagic fever caused by Lassa virus (LASV), such as enzyme immunoassays for the detection of LASV antibodies and LASV antigens, were developed using the recombinant nucleoprotein (rNP) of LASV (LASV-rNP). The LASV-rNP was expressed in a recombinant baculovirus system. LASV-rNP was used as an antigen in the detection of LASV-antibodies and as an immunogen for the production of monoclonal antibodies. The LASV-rNP was also expressed in HeLa cells by transfection with the expression vector encoding cDNA of the LASV-NP gene. An immunoglobulin G enzyme-linked immunosorbent assay (ELISA) using LASV-rNP and an indirect immunofluorescence assay using LASV-rNP-expressing HeLa cells were confirmed to have high sensitivity and specificity in the detection of LASV-antibodies. A novel monoclonal antibody to LASV-rNP, monoclonal antibody 4A5, was established. A sandwich antigen capture (Ag-capture) ELISA using the monoclonal antibody and an anti-LASV-rNP rabbit serum as capture and detection antibodies, respectively, was then developed. Authentic LASV nucleoprotein in serum samples collected from hamsters experimentally infected with LASV was detected by the Ag-capture ELISA. The Ag-capture ELISA specifically detected LASV-rNP but not the rNPs of lymphocytic choriomeningitis virus or Junin virus. The sensitivity of the Ag-capture ELISA in detecting LASV antigens was comparable to that of reverse transcription-PCR in detecting LASV RNA. These LASV rNP-based diagnostics were confirmed to be useful in the diagnosis of LF even in institutes without a high containment laboratory, since the antigens can be prepared without manipulation of the infectious viruses.


1993 ◽  
Vol 39 (6) ◽  
pp. 942-947 ◽  
Author(s):  
D A Monaghan ◽  
M J Power ◽  
P F Fottrell

Abstract We have developed and thoroughly validated a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA) on microtiter plates for osteocalcin in human serum with use of an antibody raised against human osteocalcin. We used a monoclonal antibody against bovine osteocalcin as the capture antibody; the second antibody was a polyclonal antibody against human osteocalcin. The amount of bound second antibody was determined with use of swine anti-rabbit antibody labeled with horseradish peroxidase. We demonstrated independence of volume and determined the recovery of added standard and within- and between-assay precision. The minimal detection limit for osteocalcin was between 1.0 and 1.5 micrograms/L and the midpoint of the standard curve ranged from 14 to 17 micrograms/L. The intraassay CV was < or = 8% in the range 2.7-52 micrograms/L; the interassay CV was usually < or = 15% in the same range. Analytical recovery of human osteocalcin standard added to serum samples was consistently > 90%. Values for osteocalcin measured in serum from 44 normal subjects were similar to those obtained with a competitive enzyme immunoassay (EIA) that used a monoclonal antibody against bovine osteocalcin. There was a good correlation between the two assays [r2 = 0.877, slope and intercept (+/- SE) = 0.88(+/- 0.051) and 0.316(+/- 0.523), respectively]. The range and mean (+/- SD) for the sandwich ELISA and the competitive EIA were 1.7-18.1 micrograms/L [8.7(+/- 4.4) micrograms/L] and 1.9-22.8 micrograms/L [9.1(+/- 4.4) micrograms/L], respectively.


Author(s):  
Devi Oktafiani ◽  
Ni Luh Ayu Megasari ◽  
Elsa Fitriana ◽  
Nasronudin ◽  
Maria Inge Lusida ◽  
...  

Background: Human herpesvirus 8 (HHV-8) infection is etiologically related to Kaposi’s sarcoma. Antibodies directed against HHV-8 can be detected in 80%–95% of HIV-seropositive patients with KS. HHV-8 serological tests have been done in several countries in Southeast Asia such as Malaysia, and Thailand however no serological data is available in Indonesia. This study was to examine the presence of HHV-8 antibodies in HIV-positive patients in Surabaya, Indonesia. Material and methods: Ninety-one serum samples were collected from HIV-positive patients in Surabaya, Indonesia. Human immunodeficiency virus-positive serum samples were collected from 10 homosexual men, 25 intravenous drug users (IVDUs) and 56 heterosexuals. Serums were then tested for the presence of HHV-8 antibody by using sandwich ELISA (Abbexa Ltd, Cambridge, UK). Results: The total of 91 HIV-infected were testing with antibodies to HHV-8 using enzyme-linked immunosorbent assay. Antibodies of HHV-8 were detected in 7/91 (7.7%) of the samples. According to a gender, six men (85.7%) and a women (14.3%) were positive of HHV-8 antibodies. No correlation regarding the gender and age from this study. The antibodies of HHV-8 was detected among intravenous drug users (IVDUs) men 5/7 (42.8%) and 2/7 (28.6%) from homosexual and heterosexual, respectively. Conclusion: This study found the presence of HHV-8 antibodies in 7.7% of patients in Surabaya, Indonesia. This finding was higher more than Southeast Asian countries. The patients with a positive result could suggest measures to prevent HHV-8 infection.


2003 ◽  
Vol 10 (3) ◽  
pp. 394-398 ◽  
Author(s):  
Won-Jong Jang ◽  
Myung-Suk Huh ◽  
Kyung-Hee Park ◽  
Myung-Sik Choi ◽  
Ik-Sang Kim

ABSTRACT To differentiate scrub typhus from other acute febrile diseases, a rapid and reliable serological diagnosis is important. We developed an immunoglobulin M (IgM) capture enzyme-linked immunosorbent assay (ELISA) for diagnosis of recent Orientia tsutsugamushi infections in humans. The 56-kDa major outer membrane protein of O. tsutsugamushi is well known as the most immunodominant antigen in scrub typhus. The test is based on the use of the biotinylated recombinant 56-kDa protein of O. tsutsugamushi Boryong, Bor56, which was expressed as a fusion protein with a maltose-binding protein in Escherichia coli. In the test, the serum IgM antibodies were captured by anti-human IgM antibodies coated onto a microtiter plate. The captured IgM antibodies were revealed through sequential addition of biotinylated Bor56 antigen and peroxidase-conjugated streptavidin to the plate. The IgM capture ELISA was compared with the immunofluorescence antibody assay (IFA) by testing 176 serum samples from patients with diagnosed cases of rickettsial disease and patients with other acute febrile diseases. Of the 81 IgG IFA-positive samples, 78 tested positive (sensitivity, 96.3%) and all 31 IgM IFA-positive samples tested positive (sensitivity, 100%) by the IgM capture ELISA. The specificity of the IgM capture ELISA was 99%, and 1 of the 95 IFA-negative samples was positive in the assay. These results strongly suggest that IgM capture ELISA using the recombinant Bor56 antigen is a reliable and detailed method for the detection of early O. tsutsugamushi infection.


2005 ◽  
Vol 12 (7) ◽  
pp. 848-854 ◽  
Author(s):  
Fuxun Yu ◽  
Mai Quynh Le ◽  
Shingo Inoue ◽  
Hong Thi Cam Thai ◽  
Futoshi Hasebe ◽  
...  

ABSTRACT Severe acute respiratory syndrome (SARS) is a recently emerged human disease associated with pneumonia. Inapparent infection with SARS coronavirus (CoV) is not well characterized. To develop a safe, simple, and reliable screening method for SARS diagnosis and epidemiological study, two recombinant SARS-CoV nucleocapsid proteins (N′ protein and NΔ121 protein) were expressed in Escherichia coli, purified by affinity chromatography, and used as antigens for indirect, immunoglobulin G enzyme-linked immunosorbent assays (ELISA). Serum samples collected from healthy volunteers and SARS patients in Vietnam were used to evaluate the newly developed methods. The N′ protein-based ELISA showed a highly nonspecific reaction. The NΔ121 protein-based ELISA, with a nonspecific reaction drastically reduced compared to that of the nearly-whole-length N′ protein-based ELISA, resulted in higher rates of positive reactions, higher titers, and earlier detection than the SARS-CoV-infected cell lysate-based ELISA. These results indicate that our newly developed SARS-CoV NΔ121 protein-based ELISA is not only safe but also a more specific and more sensitive method to diagnose SARS-CoV infection and hence a useful tool for large-scale epidemiological studies. To identify inapparent SARS-CoV infections, serum samples collected from health care workers (HCWs) in Vietnam were screened by the NΔ121 protein-based ELISA, and positive samples were confirmed by a virus neutralization test. Four out of 149 HCWs were identified to have inapparent SARS-CoV infection in Vietnam, indicating that subclinical SARS-CoV infection in Vietnam is rare but does exist.


2011 ◽  
Vol 18 (6) ◽  
pp. 1034-1037 ◽  
Author(s):  
Dean A. Jobe ◽  
Todd J. Kowalski ◽  
Marissa Bloemke ◽  
S. D. Lovrich ◽  
Steven M. Callister

ABSTRACTWe determined whether the levels of OspC borreliacidal antibodies declined following treatment of early Lyme disease and whether the OspC7 peptide enzyme-linked immunosorbent assay (ELISA) could be used as an alternative test for detecting the response. Serum samples were collected from 37 subjects at the onset of illness and 2 and 6 months after treatment with doxycycline. The ELISA detected IgM and IgG OspC7 antibodies within 2 months in 18 (49%) and 5 (14%) sera, respectively. Moreover, the sera from 12 subjects who tested positive by the ELISA also showed borreliacidal activity which was completely abrogated when the antibodies to OspC7 were removed. The borreliacidal activity decreased greater than 4-fold in each seropositive patient within 6 months after treatment, and the findings were accurately predicted by the IgM ELISA. The results confirmed that the ELISA was an effective alternative for detection of OspC borreliacidal antibodies produced during early Lyme disease in humans and also provided strong evidence that a significant decline in the response coincides with successful treatment of the illness.


2003 ◽  
Vol 10 (1) ◽  
pp. 177-179 ◽  
Author(s):  
Harry E. Prince ◽  
Wayne R. Hogrefe

ABSTRACT During the 2001 U. S. West Nile virus (WNV) season, 163 specimens were reactive in an in-house WNV-specific immunoglobulin M (IgM) screening enzyme-linked immunosorbent assay (ELISA) and were referred to either the Centers for Disease Control and Prevention or the appropriate state public health laboratory (CDC/SPHL) for additional testing. CDC/SPHL supplied results for 124 specimens that could be further evaluated in-house: 70 specimens were nonreactive in the CDC/SPHL WNV-specific IgM screening assay, and 54 specimens were reactive. These specimens were used to evaluate a modified in-house WNV-specific IgM ELISA that incorporated background subtraction to identify nonspecific reactivity and thus improve assay specificity. Of the 70 CDC/SPHL nonreactive samples, 49 (70%) were nonreactive in the modified ELISA; of the 54 CDC/SPHL reactive samples, 51 (94%) were reactive in the modified ELISA. Confirmatory studies performed by CDC/SPHL indicated that 38 CDC/SPHL screen-reactive specimens represented true WNV infection; all 38 specimens were reactive in the modified in-house WNV-specific IgM ELISA. These findings demonstrate that an in-house ELISA system for WNV-specific IgM effectively identifies patients with WNV infection.


Sign in / Sign up

Export Citation Format

Share Document