Early Clinical and Radiological outcomes of the New Anatomic Knee System : Minimum 3-year Follow-up.

2020 ◽  
Author(s):  
Dong Jin Ryu ◽  
Yoon Sang Jeon ◽  
Byung Ki Shin ◽  
Yeop Na ◽  
Sung Jun Park ◽  
...  

Abstract Background: For total knee arthroplasty (TKA), implant design and proper coverage are important for achieving patient satisfaction. An asymmetrical anatomic implant (Persona® knee system, Zimmer Biomet, Warsaw, Indiana) enables accurate coverage and minimal bone cutting. This study aimed to analyze the clinical and radiological outcomes of TKA using an asymmetrical anatomic implant over a minimum 3-year follow-up.Methods: The medical records of 94 patients who underwent 132 TKAs using the Persona® knee system, between April 2015 and January 2016 were reviewed. Pre- and post-operative clinical outcomes (assessed using the International Knee Documentation Committee (IKDC), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and Knee Injury and Osteoarthritis Outcome Score (KOOS) scores, and range of motion (ROM) were reviewed. The mechanical hip-knee-ankle (HKA) axis, component overhang and underhang and presence of a radiolucent line (RLL) were evaluated. Liner thickness were also reviewed.Results: At 3-year follow-up, the mean ROM improved from 108.4° to 130.3°. The mean IKDC subjective, WOMAC and global KOOS score significantly improved from 29.2 to 70.3, from 64.2 to 11.5, and from 66.6 to 21.7, respectively (p<0.0001). The mean mechanical HKA axis indicated the correction of the malalignment (from 9.2° varus to 0.3° varus, p<0.001). The incidence rates of >3-mm bone-to-implant size mismatch were 6.8% and 8.3% for the femoral and tibial components, respectively. RLL was found in seven cases, but they were small (>2 mm) and did not progress. In 36.3% of the knees, the additional liner thickness (11 or 13mm) was used. No case of implant loosening or early failure related to the implant design occurred. Conclusion: TKA using the Persona® knee system improved all the clinical knee scores and ROM without signs of early failure. This knee system also provides more implant size options than the conventional TKA systems and facilitates ligament balancing.

Author(s):  
Mallesh Rathod ◽  
Sandeep Kumar Kanugula ◽  
Venugopal S. M. ◽  
Jagadeesh Gudaru

<p class="abstract"><strong>Background:</strong> Total knee arthroplasty (TKA) ­­­­­­is one of the most successful surgical procedure with over 90% survival rate at 10 to 15 years. It provides a stable, pain free range of motion (ROM) for day to day activities. The aim of this study is to evaluate various factors determining ROM after TKA.</p><p class="abstract"><strong>Methods:</strong> 348 patients with 390 knees treated with TKA using cruciate retaining (CR) and posterior stabilized (PS) prosthesis were included and analysed. Mean follow up period was 18 months. Patients were analysed for factors like age, sex, diagnosis, body mass index (BMI), pre-operative exercises, ROM, deformity, posterior femoral condylar offset (PFCO), posterior tibial slope (PTS), post-operative rehabilitation and implant design (CR vs PS). Statistical analysis of above factors on knee ROM was done. Patients were assessed pre-operatively, at 6 weeks, 3, 6, 12 and 18 months post-operatively.<strong></strong></p><p class="abstract"><strong>Results:</strong> Age and sex did not affect the final ROM. The mean knee ROM improved from 86.87° to 96.95°. Factors like BMI, deformity had negative correlation and Pre-operative diagnosis, exercises, knee scores, good preoperative ROM, PFCO, PTS had positive correlation on ROM.</p><p class="abstract"><strong>Conclusions:</strong> Pre-operative exercises, diagnosis, ROM, deformity, BMI, PFCO and PTS were important factors which influence ROM in TKA. Patient selection and preoperative counselling are important for good clinical outcome.</p>


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 807.3-807
Author(s):  
I. Moriyama

Background:No widely accepted view or criteria currently exist concerning whether or not patellar replacement (resurfacing) should accompany total knee arthroplasty for osteoarthritis of the knee.1)2)3)Objectives:We recently devised our own criteria for application of patellar replacement and performed selective patellar replacement in accordance with this set of criteria. The clinical outcome was analyzed.Methods:The study involved 1150 knees on which total knee arthroplasty was performed between 2005 and 2019 because of osteoarthritis of the knee. The mean age at operation was 73, and the mean postoperative follow-up period was 91 months. Our criteria for application of patellar replacement are given below. Criterion A pertains to evaluation of preoperative clinical symptoms related to the patellofemoral joint: (a) interview regarding presence/absence of pain around the patella, (b) cracking or pain heard or felt when standing up from a low chair, (c) pain when going upstairs/downstairs. Because it is difficult for individual patients to identify the origin of pain (patellofemoral joint or femorotibial joint), the examiner advised each patient about the location of the patellofemoral joint when checking for these symptoms. Criterion B pertains to intense narrowing or disappearance of the patellofemoral joint space on preoperative X-ray of the knee. Criterion C pertains to the intraoperatively assessed extent of patellar cartilage degeneration corresponding to class 4 of the Outerbridge classification. Patellar replacement was applied to cases satisfying at least one of these sets of criteria (A-a,-b,-c, B and C). Postoperatively, pain of the patellofemoral joint was evaluated again at the time of the last observation, using Criterion A-a,-b,-c.Results:Patellar replacement was applied to 110 knees in accordance with the criteria mentioned above. There were 82 knees satisfying at least one of the Criterion sets A-a,-b,-c, 39 knees satisfying Criterion B and 70 knees satisfying Criterion C. (Some knees satisfied 2 or 3 of Criteria A, B and C).When the pain originating from patellofemoral joint (Criterion A) was clinically assessed at the time of last observation, pain was not seen in any knee of the replacement group and the non-replacement group.Conclusion:Whether or not patellar replacement is needed should be determined on the basis of the symptoms or findings related to the patellofemoral joint, and we see no necessity of patellar replacement in cases free of such symptoms/findings. When surgery was performed in accordance with the criteria on patellar replacement as devised by us, the clinical outcome of the operated patellofemoral joint was favorable, although the follow-up period was not long. Although further follow-up is needed, the results obtained indicate that selective patellar replacement yields favorable outcome if applied to cases judged indicated with appropriate criteria.References:[1]The Effect of Surgeon Preference for Selective Patellar Resurfacing on Revision Risk in Total Knee Replacement: An Instrumental Variable Analysis of 136,116 Procedures from the Australian Orthopaedic Association National Joint Replacement Registry.Vertullo CJ, Graves SE, Cuthbert AR, Lewis PL J Bone Joint Surg Am. 2019 Jul 17;101(14):1261-1270[2]Resurfaced versus Non-Resurfaced Patella in Total Knee Arthroplasty.Allen W1, Eichinger J, Friedman R. Indian J Orthop. 2018 Jul-Aug;52(4):393-398.[3]Is Selectively Not Resurfacing the Patella an Acceptable Practice in Primary Total Knee Arthroplasty?Maradit-Kremers H, Haque OJ, Kremers WK, Berry DJ, Lewallen DG, Trousdale RT, Sierra RJ. J Arthroplasty. 2017 Apr;32(4):1143-1147.Disclosure of Interests:None declared


2013 ◽  
Vol 16 (02) ◽  
pp. 1350007
Author(s):  
P. Motwani ◽  
A. Jariwala ◽  
N. Valentine

Background: Computer Navigation in Total Knee Replacement (TKR) has completed more than a decade since its inception. From that time, numerous studies have been done to see its effect on the variables of surgery and its outcome. Some studies have shown that it is definitely beneficial while others have negated its superiority over conventional techniques. This is an early outcome study on the results of navigation TKR in terms of alignment and clinical outcome at three years post-operatively. Methods: In the present study, 128 patients who had undergone navigation TKR (128 TKR) between January 2006 and November 2009 were included. The navigation system used was orthoPilot®. Patients were assessed post-operatively at one and three year using knee society score (KSS) and knee function score (KFS). All patients completed one year follow-up and 55 patients completed three year follow-up. From 128 patients, 40 navigated TKR patients operated between November 2007 and 2009 and were compared with 40 patients operated by conventional TKR operated between July 2007 and December 2008. Results: The mean KSS at 1 year post-operatively was 85.60 and at 3 years was 85.87. The mean KFS at 1 year post-operatively was 69.30 and at 3 years was 68.00. There was no statistically significant difference between navigation TKR and conventional TKR in terms of anatomical femoro-tibial alignment, femoral component alignment in coronal and sagittal plane and tibial component alignment in coronal plane. However, there was statistically significant difference between tibial component alignment in sagittal plane (p = 0.000) between both the groups. Conclusion: Computer navigation TKR affords a possibility to place both the femoral and tibial component very precisely without the risk of any greater axis deviation from ideal value. It helps in reducing the outliers in alignment of the limb and that of component and that improves the overall implant survival for a long time post-operatively.


2010 ◽  
Vol 30 (S 01) ◽  
pp. S104-S106
Author(s):  
W. Miesbach ◽  
L. M. Sahner ◽  
A. Kurth ◽  
B. Habermann

Summary Purpose Purpose of this retrospective study was to evaluate our own results after total knee replacement in patients with haemophilia. Patients, material, method: 30 patients with haemophilia who underwent total knee replacement between 1987 and 2005 were included. We used the clinical and radiological Knee Society Score. Furthermore, the Petterson and the Arnold and Hilgartner score were applied. Results: The mean age at the time of surgery was 43.2 (27–66). At the time of follow- up examination the mean age was 51.6 (30–82) years. The mean follow-up was 7.1 (2–20) years. Preoperative, he mean Arnold and Hilgartner score was 4.17 (± 0.59) and the mean Petterson-Score was 9 ± 2.29. Compared to the preoperative deficiency in knee function (KSS-Score 88.17 ± 33.58) an improvement with 166.67 (± 22.73) points was seen. 1 patient showed an aseptic loosening after 11 years. Discussion: Total knee replacement in patients with haemophilia improves knee function and quality of life. The results of our study represent results in earlier published studies. Compared to a non-haemo-philic normal population the rate of perioper-ative complications was not increased.


2020 ◽  
pp. 2050020
Author(s):  
Xabier Foruria ◽  
Jesús Moreta ◽  
Carlos Jaramillo ◽  
Ane Anton ◽  
Isidoro Calvo ◽  
...  

Objective: Patient-specific positioning guides have been designed to improve precision in total knee arthroplasty. The aim of this study is to evaluate the medium-term clinical and radiological outcomes with magnetic resonance imaging-based patient-specific positioning guides. Material and methods: We retrospectively reviewed patients from two centers treated with total knee arthroplasty performed with patient-specific positioning guides. We enrolled patients operated on between January 2011 and December 2013, with a minimum follow-up of 5 years. Preoperative and postoperative hip knee angle (HKA) and position of each component in the coronal plane were assessed. Overall malalignment was defined as an outlier of more than [Formula: see text] from the neutral mechanical axis and specific malalignment as when any component showed more than [Formula: see text] of deviation. Clinical outcomes were evaluated using the Hospital for Special Surgery (HSS) knee Score. Results: This study included 68 patients with a mean age of 72 years. The mean postoperative alignment (HKA) was [Formula: see text] and 26.5% of patients showed coronal malalignment [Formula: see text]. Regarding femoral components, 19.1% showed specific malalignment [Formula: see text], while 11.7% of tibial components were classified as outliers. The mean HSS Knee Score at final follow up was 89.2. Patients whose implants were mechanically aligned did not obtain better functional outcomes ([Formula: see text]). Conclusion: In our series, the use of patient-specific positioning guides resulted in a range of mechanical malalignment, similar to conventional instrumentation results reported in the literature.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Long Zhang ◽  
Fangfang Fan ◽  
Litong Qi ◽  
Jia Jia ◽  
Ying Yang ◽  
...  

Abstract Background Hypertension and arterial vasculopathy may be mutual causes and effects. It is unknown whether carotid intima-media thickness (cIMT) is reliably predictive of the presence of newly developed hypertension in the Chinese population. This study evaluated the impacts of cIMT on new-onset hypertension in a community-based population without hypertension at baseline in China. Methods A total of 672 Chinese subjects who had complete data for demographics, baseline and follow-up blood pressure measurements, and cIMT measurements at baseline were included in our study. Baseline cIMT was obtained under standardized procedures using the GE Vivid 7 ultrasound system equipped with an 8-MHz linear array vascular probe (GE Medical Systems, Milwaukee, Wl, USA). The outcome was the incidence of hypertension at follow-up. Multivariate regression models were used to access the association between baseline cIMT and the risk of new-onset hypertension. Results Subjects were 51.5 ± 4.7 years old, and 32.0% were male. The mean baseline systolic blood pressure (SBP) was 122.5 ± 10.0 mmHg. The mean baseline diastolic blood pressure (DBP) was 72.4 ± 7.5 mmHg. The number of subjects with thickened cIMT (maximum ≥0.9 mm) at baseline was 198 (29.5%). After 2.3 years of follow-up, the rate of new-onset hypertension was 12.6%. The incidence rates of hypertension in the groups with thickened cIMT and normal cIMT were 19.2 and 9.9%, respectively. In the multivariable logistic regression analyses, both the average (OR = 1.69, 95% CI: 1.30–2.19, P = 0.0001) and maximum (OR = 1.55, 95% CI: 1.23–1.95, P = 0.0002) cIMT were significantly associated with new-onset hypertension after adjustment for various confounders. The group with thickened cIMT showed a higher risk for the incidence of hypertension, with an OR of 1.82 (95% CI: 1.07–3.10, P = 0.0270), compared to the normal group. Conclusion Thickened cIMT has a strong association with incident hypertension risk in a community-based population without hypertension at baseline in China.


2020 ◽  
Vol 34 (01) ◽  
pp. 115-120
Author(s):  
Ali Utkan ◽  
Emrah Caliskan ◽  
Batuhan Gencer ◽  
Bulent Ozkurt

AbstractAlthough there are numerous studies about routine histopathological analysis during arthroplasty surgeries, most of them showed that new diagnoses have rarely been obtained as a result. The aim of this study was to evaluate the efficacy of routine pathological analyses of synovia resected during primary total knee arthroplasty in patients with osteoarthritis and its relevance in the treatment process. Of the 47 included patients who were followed up prospectively, 26 patients had clinical and histopathological concordant diagnoses and 21 patients had discrepant diagnoses. Oxford knee score and visual analogue score were performed for all the patients. Kallgren-Lawrence score was used for radiological analyses. The Mann-Whitney U test was used to examine the differences between the abnormally distributed variables. Mean age was 65.9 ± 4.3 years (range, 50–89 years) and mean follow-up time was 19 ± 7.8 months (range, 6–39 months). Grade IV gonarthrosis was found to be statistically lower in the discrepant group (p = 0.046). The mean preoperative Oxford knee score was 16.8 ± 2.3 (range, 2–23) and the mean postoperative Oxford knee score was 44.6 ± 1.8 (range, 27–48; p = 0.016). Postoperative Oxford knee scores and VAS were significantly increased in both the concordant and discrepant groups (p = 0.026 and p = 0.035, p = 0.019 and p = 0.039, respectively). Resection and histopathologic analyses of the hypertrophied and inflamed synovium encountered during primary arthroplasty procedure should be performed. This examination not only could provide crucial information that may influence the postoperative follow-up guidelines but also could help us to expand our knowledge and awareness of rare diseases that might yield osteoarthritis. The level of evidence for the study is level II.


Hand Surgery ◽  
2014 ◽  
Vol 19 (03) ◽  
pp. 357-362 ◽  
Author(s):  
Chul-Hyun Cho ◽  
Si-Wook Lee ◽  
Gu-Hee Jung

The purpose of this study was to compare the outcomes of volar plating using two different implants for distal radius fractures. Fifty-two patients with AO type C fractures were placed in either of two groups: the AO LDRS group (26 patients) or the Acu-Loc group (26 patients). Radiological parameters including radial length, radial inclination, volar tilt, and intra-articular step-off were significantly improved after surgery. The mean Mayo Wrist Performance Score was 84.6 in the AO LDRS group and 81.1 in the Acu-Loc group. The mean Subjective Wrist Value was 86.7% in the AO LDRS group and 86.3% in the Acu-Loc group. There were no significant differences between the two groups with respect to both radiological and clinical outcomes at the final follow-up evaluation. Volar fixed-angle plating for unstable distal radius fractures had satisfactory radiological and clinical outcomes. The difference of implant design did not influence overall final outcomes.


2017 ◽  
Vol 30 (09) ◽  
pp. 894-897 ◽  
Author(s):  
Alun Yewlett ◽  
Ryan Trickett ◽  
Mark Forster ◽  
Adel Ghandour ◽  
Hannah Sellars

AbstractResection of Hoffa's fat pad during total knee arthroplasty is sometimes performed to improve access and view. Opponents of this technique argue that sacrificing the fat pad potentially compromises blood supply to the patellar tendon and it can subsequently shorten. Our objective was to identify any difference in the Insall-Salvati ratio of knees undergoing total knee arthroplasty between a cohort that had Hoffa's fat pad preserved and the one that had Hoffa's fat pad completely excised. The total knee arthroplasties by two surgeons at our institution were reviewed over a 3-year period. Surgeon A routinely preserves the fat pad and surgeon B routinely excises the fat pad. Radiographs preoperatively, immediately postoperatively, and at a minimum of 1-year follow up were analyzed for the Insall-Salvati ratio. A total of 161 knees were reviewed, 65 in the preserved group and 96 in the excised group with a mean age of 67 and 70 years, respectively. The mean preoperative Insall-Salvati ratio for the preserved group was 1.12 (±0.145) and excised group 1.16 (±0.168) (p = 0.094). The mean immediate postoperative Insall-Salvati ratio for the preserved group was 1.10 (±0.154) and for excised group 1.18 (±0.194). The difference in Insall-Salvati ratio from preoperative to the immediate postoperative period in the preserved group compared with the excised group demonstrated a significant difference (p = 0.010). However, the change of Insall-Salvati ratio at 1 year did not significantly differ between the groups (p = 0.059). There does not appear to be any difference in the Insall-Salvati ratios of both groups at 1 year's follow up; therefore, this study radiologically at least supports the use of either technique.


2020 ◽  
Author(s):  
Yang Li ◽  
Xinguang Wang ◽  
Hua Tian

Abstract Background: The reconstruction of massive bone defects is one of the main challenges in revision total knee arthroplasty (RTKA). Although several methods are available, each of them has its prominent shortcomings. The purpose of this study is to review the clinical outcomes of RTKA with massive proximal tibial bone defects using patient-customized three-dimensional (3D)-printed highly porous metaphyseal cones.Methods: We retrospectively reviewed seven RTKAs with Anderson Orthopaedic Research Institute (AORI) type III tibial defects using patient-customized 3D-printed highly porous metaphyseal cones, which have been performed at a single institution between 2016 and 2018. Results: The mean age at diagnosis of the patients was 68 years old (61-77). The mean length of follow-up was 25.3 months (19-36). At the latest follow-up, no aseptic loosening or prosthetic joint infection has been determined. The mean HSS increased from 49 (39-63) to 78 (70-83) (P<0.01); the mean WOMAC increased from 59 (46-73) to 26 (12-38) (P<0.01). All patients obtained the range of motion and mechanical alignment improvement postoperatively.Conclusion: The patient-customized 3D-printed metaphyseal cone could be a promising technique in addressing severe tibial defects in RTKA. Our study shows encouraging short-term clinical and radiological outcomes with no aseptic loosening, periprosthetic infection, or fracture. Nevertheless, further follow-up and the expansion of sample size are needed to demonstrate the advantage of this innovative technique fully.


Sign in / Sign up

Export Citation Format

Share Document