Impact of Grid Connected Wind Power on Frequency Regulation in Restructured Power System

2019 ◽  
Author(s):  
Yogesh Prajapati ◽  
Dr. V Kamat ◽  
Jatinkumar Patel
2021 ◽  
Vol 1748 ◽  
pp. 052017
Author(s):  
Lei Yang ◽  
Wei Huang ◽  
Chen Wu ◽  
Shengnan Li ◽  
Yixuan Chen ◽  
...  

2013 ◽  
Vol 58 (36) ◽  
pp. 4557-4565 ◽  
Author(s):  
HaiShun Sun ◽  
Ju Liu ◽  
JinYu Wen ◽  
ShiJie Cheng ◽  
Cheng Luo ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-16
Author(s):  
Mohamed Nadour ◽  
Ahmed Essadki ◽  
Tamou Nasser

The expansion of renewable generation has raised some red flags in terms of power system stability, control, and management. For instance, unlike traditional synchronous energy sources, the doubly-fed induction generator- (DFIG-) based wind turbines (WTs) do not instinctively act against frequency deviations. In fact, the power electronics interfacing the generator, merely controlled to warrant maximum wind power conversion, make its output power and mechanical speed immune to the characteristics of the electric network frequency. Moreover, significant wind power penetration (WPP) promotes the retirement of many traditional generation groups, consequently curtailing the power system corresponding inertia and displacing the primary reserves that are essential to retain the frequency within an acceptable range of variation. This paper explores different control approaches, using backstepping, allowing DFIG-based WTs to engage actively in frequency regulation using a coordinated control of the rotor speed and pitch angle to regulate the system during both partial- and full-load operation modes. The first method momentarily discharges part of the kinetic energy stored in the WT spinning masses, and the second method follows a deloaded operation characteristic, so as to keep a specific power reserve that can be automatically activated at the events of frequency excursions. A study case considering an isolated power system that consists of synchronous generators, DFIG-based wind farm, static load, and a sudden frequency disturbance was performed. The simulation result in a Matlab/Simulink environment highlights the robustness and capability of the coordinated control scheme to furnish, under variant operation conditions, active power aid, consequently lifting the frequency nadir up to a superior level than that obtained with 0% wind power penetration in the system.


Author(s):  
Rafael Sebastián ◽  
Jerónimo Quesada

"This study presents the modelling and dynamic simulation of an Isolated Wind Power System (IWPS) consisting of a Wind Turbine Generator (WTG), a synchronous machine (SM), consumer load, dump load (DL) and a Battery Energy Storage System (BESS). First the IWPS architecture and the dynamic models of the IWPS components are described. Second, the control requirements for frequency regulation of the IWPS are studied and a PID regulator to govern the active power stored+dumped by the BESS+DL combination or supplied by the BESS along with a power sharing algorithm between the BESS and DL is presented. Finally the IWPS is simulated facing to variations to load and WTG power. The simulation results are given showing graphs of the main electrical variables in the IWPS: system frequency and voltage and active power in each component. The results show how the BESS or BESS+DL combination regulates correctly the isolated system frequency. The results also show that the BESS improves the IWPS reliability when compared with the frequency control obtained using only the DL."


2013 ◽  
Vol 448-453 ◽  
pp. 2556-2563
Author(s):  
Ye Kui Chang ◽  
Rao Liu ◽  
Chong Wang ◽  
Xin Zhang ◽  
Wei Dong Li

The third frequency adjustment is the key link of the grid frequency regulation. The admission of high capacity and rejection of small capacity policy on thermal power cause the lack of capacity of the third frequency adjustment. Wind power brings about a certain impact to the frequency stability of the power system, particularly, increasing the difficulty of the third frequency adjustment. The introduction of nuclear power into the third frequency adjustment has been proposed after analyzing the characteristics of the energy generation of different forms. This paper formulate the control strategy with the core of wind power decomposition, generator units grouping in the third frequency adjustment, after elaborating the technical feasibility and economic feasibility, and, come to a conclusion that the participation of the nuclear in the third frequency adjustment would guarantee the stability of the frequency of the power system with this control strategy in the case of the introduction of wind power to the system, by simulation analysis.


2021 ◽  
Vol 9 ◽  
Author(s):  
Qi Zhu ◽  
Yingjie Wang ◽  
Jiuxu Song ◽  
L. Jiang ◽  
Yingliang Li

Frequency stability of the power system is impacted by the increasing penetration of wind power because the wind power is intermittent. Meanwhile, sometimes the demand side loads increase quickly to require more power than total power produced. So balancing the active power in the power system to maintain the frequency is the main challenge of the high penetration of wind power to the smart grid. This paper proposes coordination rotor speed control (RSC), pitch angle control (PAC) and inertial control (IC) to control wind turbines, together with demand side response (DSR) participating in frequency regulation to balance active power in the power system. Firstly, the model of a single area load frequency control (LFC) system is obtained, which includes variable-speed wind turbines (VSWT) and DSR containing aggregated air conditioners and plug-in electric vehicles (PEVs). Then the RSC, PAC and IC, which controls wind turbines participating in frequency regulation in the power system, are introduced, respectively. Finally, the coordination of these three methods for wind turbines in different wind speeds is proposed. Case studies are carried out for the single area LFC system with a wind farm and DSR supported grid frequency. Coordination RSC and PAC combined IC are used to control wind turbines with DSR to balance active power in the power system. The proposed method used in the power system with high penetration of wind power and fluctuation of demand load is tested, respectively. Coordinated RSC or PAC with DSR can increase penetration of wind power and reduce peak load.


2014 ◽  
Vol 644-650 ◽  
pp. 3840-3843
Author(s):  
San Ming Liu ◽  
Zhi Jie Wang ◽  
Xia Sun ◽  
Yi Teng Liang ◽  
Xiao Wei Zhu

The impacts of wind disturbance on voltage regulation and frequency regulation of power system were studied. The opinion that the regulation of power flow on the tie lines between the grids constrains the integrated capacity of wind power was put forward. Based on the real condition of Inner Mongolia power grid, an engineering practical method was put forward to calculate the integrated capacity of wind power under this constraint. The relationship between wind power and spinning reserve and the impacts of other related factors on the capacity of wind power were studied as well. The impact of wind disturbance on voltage stability where the wind farms are located was studied.