Highly Sensitive Immunosensing of Carcinoembryonic Antigen Based on Gold Nanoparticles Functionalized PB@PANI Core-Shell Nanocubes as a Novel Signal Amplification Strategy

2021 ◽  
Author(s):  
Dexiang Feng ◽  
Lingzhi Chen ◽  
Menglan Fu ◽  
Peng Jiang ◽  
Xianhao Jiang ◽  
...  
The Analyst ◽  
2021 ◽  
Vol 146 (8) ◽  
pp. 2679-2688
Author(s):  
Chammari Pothipor ◽  
Noppadol Aroonyadet ◽  
Suwussa Bamrungsap ◽  
Jaroon Jakmunee ◽  
Kontad Ounnunkad

An ultrasensitive electrochemical biosensor based on a gold nanoparticles/graphene/polypyrrole composite modified electrode and a signal amplification strategy employing methylene blue is developed as a potential tool for the detection of miRNA-21.


2018 ◽  
Vol 10 (46) ◽  
pp. 5499-5506 ◽  
Author(s):  
Min Shi ◽  
Jingjin Zhao ◽  
Shuting Li ◽  
Jianniao Tian ◽  
Shulin Zhao

A novel chemiluminescence (CL) signal amplification strategy based on luminophore and antigen co-loaded gold nanoparticles was developed to improve the sensitivity of capillary electrophoresis CL assay.


2014 ◽  
Vol 6 (7) ◽  
pp. 2221-2226 ◽  
Author(s):  
Xiao-Yan Li ◽  
Zi Yi ◽  
Hao Tang ◽  
Xia Chu ◽  
Ru-Qin Yu

Highly sensitive electrochemical immune analysis was achieved based on dual signal amplification of AuNPs and telomerase extension reaction.


Biosensors ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 50 ◽  
Author(s):  
Hao-Chun Chiang ◽  
Yanyan Wang ◽  
Qi Zhang ◽  
Kalle Levon

A highly sensitive electrochemical biosensor with a signal amplification platform of electrodeposited gold nanoparticle (AuNP) has been developed and characterized. The sizes of the synthesized AuNP were found to be critical for the performance of biosensor in which the sizes were dependent on HAuCl4 and acid concentrations; as well as on scan cycles and scan rates in the gold electro-reduction step. Systematic investigations of the adsorption of proteins with different sizes from aqueous electrolyte solution onto the electrodeposited AuNP surface were performed with a potentiometric method and calibrated by design of experiment (DOE). The resulting amperometric glucose biosensors was demonstrated to have a low detection limit (> 50 μM) and a wide linear range after optimization with AuNP electrodeposition.


2020 ◽  
Vol 56 (36) ◽  
pp. 4942-4945 ◽  
Author(s):  
Chao Jiang ◽  
Yan Huang ◽  
Ting He ◽  
Peng Huang ◽  
Jing Lin

A colorimetric/fluorescence/photoacoustic triple read-out detection of prostate specific antigen (PSA) was developed by using a silica coated Au@Ag core–shell nanorod (denoted Au@Ag@SiO2) based enzyme-linked immunosorbent assay (ELISA) system.


The Analyst ◽  
2020 ◽  
Vol 145 (1) ◽  
pp. 91-96 ◽  
Author(s):  
Jun-Tao Cao ◽  
Xiao-Long Fu ◽  
Fu-Rao Liu ◽  
Shu-Wei Ren ◽  
Yan-Ming Liu

A novel spatial-resolved electrochemiluminescent (ECL) ratiometry for cardiac troponin I (cTnI) analysis was developed using resonance energy transfer (RET) and a coreactant consumption strategy for signal amplification.