scholarly journals Improving patient safety after rigid bronchoscopy in adults: laryngeal mask airway versus face mask – a pilot study

Author(s):  
Fulvio Nisi ◽  
Gaetano Cicchitto ◽  
Francesco Puma ◽  
Vito Aldo Peduto ◽  
Antonio Galzerano
2015 ◽  
Vol 167 (2) ◽  
pp. 286-291.e1 ◽  
Author(s):  
Daniele Trevisanuto ◽  
Francesco Cavallin ◽  
Loi Ngoc Nguyen ◽  
Tien Viet Nguyen ◽  
Linh Dieu Tran ◽  
...  

1998 ◽  
Vol 13 (1) ◽  
pp. 32-43 ◽  
Author(s):  
Clifford A. Schmiesing ◽  
John G. Brock-Utne

The laryngeal mask airway (LMA) is an airway management device that has become an accepted part of anesthetic practice in both pediatric and adults surgical patients. It is inserted without the use of a laryngoscope or muscle relaxants into the hypopharynx forming a low pressure seal around the glottis. The LMA provides a better airway than a face mask with or without an oral airway. Insertion techniques are quickly learned and are described in this review. Since the LMA forms a less secure seal than an endotracheal tube (ETT), several important limitations and contraindications exist. This includes patients at high risk for regurgitation of gastric contents into the lungs causing pulmonary aspiration and patients requiring high ventilatory pressures or prolonged ventilation. These contraindications have limited its introduction and utilization in the intensive care unit (ICU). The LMA is a helpful tool in the management of both the expected and unexpected difficult airway, where it may serve both as an emergency airway and as a conduit to intubation of the trachea with an ETT over a fiberoptic bronchoscope (FOB) or gum elastic bougie. A lifesaving airway has been provided by the LMA where no other means of achieving ventilation were possible in patients, including neonates, trauma victims, woman undergoing cesarean section, and in the setting of cardiac arrest. There are very few reported uses of the LMA in the ICU. We believe that familiarity with the LMA's design, use, and limitations by critical care practitioners will increase its use in emergency airway management and in the ICU. The LMA may prove to be the first of a new generation of airway devices placed into the hypopharynx to provide an alternative to the endotracheal tube and mask airway.


2017 ◽  
Vol 103 (3) ◽  
pp. 255-260 ◽  
Author(s):  
Nicolas J Pejovic ◽  
Daniele Trevisanuto ◽  
Clare Lubulwa ◽  
Susanna Myrnerts Höök ◽  
Francesco Cavallin ◽  
...  

ObjectiveMortality rates from birth asphyxia in low-income countries remain high. Face mask ventilation (FMV) performed by midwives is the usual method of resuscitating neonates in such settings but may not always be effective. The i-gel is a cuffless laryngeal mask airway (LMA) that could enhance neonatal resuscitation performance. We aimed to compare LMA and face mask (FM) during neonatal resuscitation in a low-resource setting.SettingMulago National Referral Hospital, Kampala, Uganda.DesignThis prospective randomised clinical trial was conducted at the labour ward operating theatre. After a brief training on LMA and FM use, infants with a birth weight >2000 g and requiring positive pressure ventilation at birth were randomised to resuscitation by LMA or FM. Resuscitations were video recorded.Main outcome measuresTime to spontaneous breathing.ResultsForty-nine (24 in the LMA and 25 in the FM arm) out of 50 enrolled patients were analysed. Baseline characteristics were comparable between the two arms. Time to spontaneous breathing was shorter in LMA arm than in FM arm (mean 153 s (SD±59) vs 216 s (SD±92)). All resuscitations were effective in LMA arm, whereas 11 patients receiving FM were converted to LMA because response to FMV was unsatisfactory. There were no adverse effects.ConclusionA cuffless LMA was more effective than FM in reducing time to spontaneous breathing. LMA seems to be safe and effective in clinical practice after a short training programme. Its potential benefits on long-term outcomes need to be assessed in a larger trial.Clinical trial registryThis trial was registered in https://clinicaltrials.gov, with registration number NCT02042118.