scholarly journals Pharmacogenetic testing revisited: 5′nuclease real-time polymerase chain reaction test panels for genotyping CYP2D6 and CYP2C19

2017 ◽  
Vol Volume10 ◽  
pp. 115-128
Author(s):  
Jens Borggaard Larsen ◽  
Jan Borg Rasmussen
2020 ◽  
Vol 71 (15) ◽  
pp. 850-852 ◽  
Author(s):  
Junqing Xu ◽  
Ruodai Wu ◽  
Hua Huang ◽  
Weidong Zheng ◽  
Xinling Ren ◽  
...  

Abstract We reported computed tomographic (CT) imaging findings of 3 patients with coronavirus disease 2019 (COVID-19) pneumonia with initially negative results before CT examination and finally confirmed positive for the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by real-time reverse-transcription polymerase chain reaction assay.


2011 ◽  
Vol 37 (7) ◽  
pp. 1244-1250 ◽  
Author(s):  
Gustavo Barreto Melo ◽  
Paulo José Martins Bispo ◽  
Antonio Carlos Campos Pignatari ◽  
Ana Luisa Höfling-Lima

2017 ◽  
Vol 33 (S1) ◽  
pp. 77-77
Author(s):  
Kátia Senna ◽  
Marisa Santos ◽  
Bernardo Tura

INTRODUCTION:Clostridium difficile infection is the leading cause of nosocomial diarrhea in developed countries and may progress to pseudomembranous colitis, sepsis and death. The risk factors are antibiotics use, advanced age and prolonged hospitalization. The diagnosis of Clostridium difficile infection is based on clinical history in combination with laboratory tests, which detect the Clostridium difficile presence or toxins. Clostridium difficile remains in spore form contaminating the environment and requiring measures to prevent hospital transmission. Tests with more accurate results to identify true carriers of Clostridium difficile allow the clinician to determine a safer treatment. This study evaluated accuracy and cost-effectiveness of the real-time polymerase chain reaction compared with the enzyme-linked immunosorbent assay from the perspective of a Brazilian public cardiology hospital.METHODS:A study diagram was constructed by type of test, linking the data of prevalence in hospital, accuracy and direct costs of tests. The costs were based on a hypothetical population comparing two strategies to identify the incremental expenditure between technologies. The analysis included comparisons for each test versus no test, and with each other. The prices were converted to the American currency taking into account the date of purchase of each product and respective price.RESULTS:For real-time polymerase chain reaction test versus no test, 214 patients would have tested to justify one empirical treatment suspension, at a cost of USD90,926.46. For enzyme-linked immunosorbent assay test, to prevent one unnecessary treatment, 375 patients would have to be tested at a cost of USD6,603.75. In the comparative analysis, only a single false-positive patient would have the treatment suspended after performing 375 real-time polymerase chain reaction tests at USD424.89 each one (USD159,333.75 in total). An incremental cost of USD152,730.00 may be necessary to benefit a single patient by discontinuing empirical treatment.CONCLUSIONS:The Real-time polymerase chain reaction test has restrictions as a test of choice for the diagnosis of Clostridium difficile infection, in services with low disease prevalence. It undergoes a significant change in its positive predictive value and does not offer a great impact in the clinical diagnosis.


2021 ◽  
Vol 59 (237) ◽  
Author(s):  
Narayani Maharjan ◽  
Niresh Thapa ◽  
Bibek Pun Magar ◽  
Muna Maharjan ◽  
Jiancheng Tu

Introduction: The emergence of severe acute respiratory syndrome coronavirus-2 pandemic is critically challenging the whole world. The real-time reverse transcriptase-polymerase chain reaction is the most widely used confirmatory test for COVID-19 detection. This study aimed to find out the prevalence of COVID-19 infection detected by gold standard reverse transcriptase-polymerase chain reaction test in a tertiary care center of Nepal. Methods: A descriptive cross-sectional study was conducted in Karnali Academy of Health Sciences from May to August 2020 after taking ethical approval from the Institutional Review Committee of Karnali Academy of Health Sciences, Jumla. Convenient sampling was used. A total of 361 participants enrolled in this study who have done real-time reverse transcriptase-polymerase chain reaction for screening of COVID-19 infection. Also, a designated questionnaire was obtained from persons with a travel history and close contact. Statistical Package for the Social Sciences software was used for the statistical analysis. Point estimate at 95% Confidence Interval was calculated along with frequency and proportion for binary data. Results: The prevalence of COVID-19 was 167 (46.3%) (95% Confidence Interval= 41.16-51.44) by real-time reverse transcriptase-polymerase chain reaction test. Out of 361 samples, 339 (93.9%) were male and 22 (6%) were female. The highest frequency of the participants belongs to the age groups of 20-40 years. Conclusions: The findings showed a high prevalence of COVID-19 detected by reverse transcriptase-polymerase chain reaction test. Further studies are necessary to improve the precision of prevalence estimations.


Sign in / Sign up

Export Citation Format

Share Document