POWER QUALITY ANALYSIS IN A HERCULES AIRCRAFT POWER DISTRIBUTION SYSTEM

Author(s):  
J. Cartier ◽  
D. Bouchard ◽  
A. Chikhani
2015 ◽  
Vol 781 ◽  
pp. 272-275 ◽  
Author(s):  
Sarayuth Wetchakama ◽  
Uthane Supatti

This paper presents power quality analysis and impact of power solar rooftop on distribution system of the Provincial Electricity Authority (PEA) in Thailand. The case study used in this paper is a 996 kWpeak solar photovoltaic (PV) distribution generator (DG) system which connected to 22 kV at Pluak Daeng 3 substation in Pluak Daeng, Rayong, Thailand. Experiment and simulation are used in power quality analysis. The simulation is conducted through the DIgSILENT PowerFactory program to analyze the behavior of the DG system on the PEA power distribution. Experimental results show that all qualities of power from solar rooftop meet the PEA’s standard criteria while the simulation results show that over 4 MW of solar rooftop generation, the voltage of utility grid system would be affected during cloudy periods. However, if the PV system produces 2-3 MW of power, the distribution system would be benefit.


Author(s):  
A. Sathik Basha ◽  
M. Ramasamy

Increased utilization of nonlinear loads in the power distribution system with profound integration of renewable energy requires improved power quality control. This paper proposes a Reformed Second Order Generalized Integrated (R-SOGI) control scheme for enhancing the output of the Dynamic Voltage Restorer (DVR) for the objective of achieving the desired sinusoidal voltage wave shape at the common point of services and harmonic reduction. The DVR incorporates a Solar Photovoltaic (SPV) system using the Z-source Inverter (ZSI), providing the necessary active power to mitigate the voltage sag/swell and power demand. ZSI offers step-down as well as step-up abilities, it makes the converters to operate in the conditions of shoot-through. Therefore, the application of ZSI-based DVR topology seems very promising. The compensating reference voltage is generated by the R-SOGI algorithm, which offers superior output under conditions for grid voltage irregularities, including voltage sag/swell and unbalanced and distorted utility grid voltages. In comparison to DVR based on the VSI voltage inverter (VSI), the response from ZSI-DVR to a reduction of voltage distortions and harmonics is investigated. An experimental SPV ZSI-DVR prototype is developed in the laboratory to check the effectiveness of the controller and is tested under balanced and unbalanced supply and dynamic load conditions.


Author(s):  
Nilesh B. Mirajkar ◽  
Rajesh R. Dharaskar ◽  
P. Kolhe ◽  
Tousif G. Kazi ◽  
Rakesh R. Jadhav ◽  
...  

2016 ◽  
Vol 818 ◽  
pp. 52-57 ◽  
Author(s):  
Faridullah Kakar ◽  
Abdullah Asuhaimi bin Mohd Zin ◽  
Mohd Hafiz bin Habibuddin

Voltage sag and harmonics are the most frequent power quality problems faced by industrial and commercial customers today. Situation has been aggravated by modern sensitive industrial equipments which introduce system harmonics due to their inherent V-I characteristics. In this paper, proportional integral (PI) control technique based dynamic voltage restorer (DVR) is implemented in power distribution system to suppress voltage sag and harmonics under linear, non-linear and induction motor load conditions. Real-time power distribution system and DVR test models are built in Matlab/Simulink software. Simulation results exhibit excellent PI control approach with effective performance yielding excellent voltage regulation.


2013 ◽  
Vol 14 (1) ◽  
pp. 67-78 ◽  
Author(s):  
Sumit Mazumder ◽  
Arindam Ghosh ◽  
Firuz Zare

Abstract Severe power quality problems can arise when a large number of single-phase distributed energy resources (DERs) are connected to a low-voltage power distribution system. Due to the random location and size of DERs, it may so happen that a particular phase generates excess power than its load demand. In such an event, the excess power will be fed back to the distribution substation and will eventually find its way to the transmission network, causing undesirable voltage–current unbalance. As a solution to this problem, the article proposes the use of a distribution static compensator (DSTATCOM), which regulates voltage at the point of common coupling (PCC), thereby ensuring balanced current flow from and to the distribution substation. Additionally, this device can also support the distribution network in the absence of the utility connection, making the distribution system work as a microgrid. The proposals are validated through extensive digital computer simulation studies using PSCADTM.


The Indian economy has been growing at a fast pace since the beginning of this millennium. Due to constraints in the availability of fuel and environmental concerns, the power generation sector has not kept pace with other industrial sectors. One way of increasing the power availability is by reducing the high losses in the existing power transmission and distribution systems. The current increases in the motor windings when the voltages in the three phases are unbalanced. Compensation for reactive power and unbalance in the power distribution system are key factors in improving the power quality to the end user. A Distributed Static Compensator [DSTATCOM] is a custom power device, which is connected in shunt with the load in the distribution system to compensate the reactive power due unbalanced loads. The performance of the DSTATCOM is based on the control technique used for finding the voltage referred and current components to be considered. Voltage compensation is defined as the error in voltage in the grid and that the value of voltage that has to be induced in the grid. This is analyzed by using DSTATCOM for voltage compensation with series converter controller block. This paper gives the simulation of voltage compensation to rectify the issue of voltage swell/sag in order to improve the power quality in the distribution system.


Author(s):  
Jasti Venkata Ramesh Babu ◽  
Malligunta Kiran Kumar

Power quality is one big issue in power system and a big challenge for power engineers today. Electrical consumers (or otherwise load devices) expect electrical power received power should be of first-class. Bad quality in electrical power directs to fuse blowing, machine overheating, increase in distribution losses, damage to sensitive load devices and many more. DSTATCOM is one of the FACTS controllers designed to improve the quality in electrical power and thus improving the performance of distribution system. This paper presents a multilevel DSTATCOM topology to enhance power quality in power distribution system delivering high-quality power to the customer load devices. Diode-clamped structure is employed for multi-level DSTATCOM structure. ‘PQ’ based control strategy generates reference signal which is further processed through level-shifted multi-carrier PWM strategy for the generation of gate pulses to multi-level DSTATCOM structure. Simulation work of proposed system is developed and the result analysis is presented using MATLAB/SIMULINK software. Performance of multi-level DSTATCOM topology is verified with fixed and variable loads.