Dissolved oxygen controller based on on-line measurements of ammonium combining feed-forward and feedback

2002 ◽  
Vol 45 (4-5) ◽  
pp. 453-460 ◽  
Author(s):  
P. Ingildsen ◽  
U. Jeppsson ◽  
G. Olsson

As the largest single energy-consuming component in most biological wastewater treatment systems, control of aeration is of great interest seen from an energy savings point of view. This paper suggests a simple way of using on-line ammonium measurements to control aeration in a pre-denitrification plant by controlling the dissolved oxygen setpoint. The controller works primarily by feed-forward based on an ammonium sensor located at the head of the aerobic process part. Using online in-situ sensor measurements directly from the process have the important advantage over effluent measurements that there is no or very short time delay for information. The controller has been implemented in a full-scale wastewater treatment plant for a period of 35 days. During the experiment two identical activated sludge lines were used. The controller was implemented in one line, while the other line worked as a reference for comparison. The preliminary results indicate that the described control strategy leads to energy savings for the aeration in the region of 5–15%, while maintaining approximately the same effluent quality as in the reference line. Even higher energy savings can probably be achieved by optimising the controller. An automatic procedure for updating the controller parameters based on dynamic effluent ammonium measurement has been tested.

2009 ◽  
Vol 2009 (13) ◽  
pp. 3722-3729 ◽  
Author(s):  
Thomas Walz ◽  
J.R. Coughenour ◽  
Kevin Williams ◽  
John Jacobs ◽  
Larry Shone ◽  
...  

2009 ◽  
Vol 59 (7) ◽  
pp. 1291-1297
Author(s):  
H. Poutiainen ◽  
S. Laitinen ◽  
P. Juntunen ◽  
H. Heinonen-Tanski

We describe a novel application for a microwave on-line sensor to measure the total solids (TS) load entering a municipal wastewater treatment plant (WWTP) from slaughterhouse sewage and some sanitary wastewaters. Measuring this kind of wastewater stream is very challenging, because it contains a high, but varying organic load with nitrogen, phosphorus and microorganisms. The reliability of the measured signal was studied by comparison with laboratory analyses and a correlation is presented of TS-value with other parameters that are typically followed in a wastewater treatment process. The results suggest that on-line microwave sensoring could be used to monitor total solids in wastewater influent. Our results show that the on-line microwave sensor and laboratory reference analyses give similar results with a good correlation between the two techniques. Furthermore, we demonstrate that the total solids values correlate well with conductivity, total nitrogen and BOD7 values but not with phosphorus, pH and temperature.


Sign in / Sign up

Export Citation Format

Share Document