Performance evaluation of physicochemical processes for biologically pre-treated livestock wastewater

2005 ◽  
Vol 52 (10-11) ◽  
pp. 107-115 ◽  
Author(s):  
S.W. Hong ◽  
Y.S. Choi ◽  
G. Kwon ◽  
K.Y. Park

The use of a combination of biological and physicochemical methods is a promising technique to reduce highly concentrated pollutants in livestock wastewater: firstly, biodegradable organic matters, nitrogen and a part of phosphorus should be removed in a biological treatment process and then residual non-biodegradable organic matters, color and phosphorus be eliminated by physicochemical methods. In this study, therefore, the integrations of chemical coagulation, activated carbon adsorption, Fenton oxidation and ozonation were evaluated to provide an appropriate post-treatment process for biologically pre-treated livestock wastewater. With applying a single method such as coagulation and Fenton oxidation, a yellowish brown color and COD still remained. According to the experimental result, the quality of treated wastewater including color was enough to be discharged after chemical coagulation followed by ozonation or Fenton oxidation process. Among these, ozonation was the most effective technology for decolorization. Neither simple biological nor physicochemical process provides an adequate treatability for the sufficient depletion of organics and decolorization when treating livestock wastewater. Considering only the removal efficiency, the integration of Fenton oxidation and ozonation would be an efficient alternative as a post-treatment.

Author(s):  
Vijay A. Juwar ◽  
Ajit P. Rathod

Abstract The present study deals with the treatment of complex waste (WW) treated for removal of chemical oxygen demand (COD) of the food industry by a sono-Fenton process using a batch reactor. The response surface methodology (RSM) was employed to investigate the five independent variables, such as reaction time, the molar ratio of H2O2/Fe2+, volume ratio of H2O2/WW, pH of waste, and ultrasonic density on COD removal. The experimental data was optimized. The optimization yields the conditions: Reaction time of 24 min, HP:Fe molar ratio of 2.8, HP:WW volume ratio of 1.9 ml/L, pH of 3.6 and an ultrasonic density of 1.8 W/L. The predicted value of COD was 91% and the experimental result was 90%. The composite desirability value (D) of the predicted percent of COD removal at the optimized level of variables was close to one (D = 0.991).


2004 ◽  
Vol 50 (2) ◽  
pp. 47-53 ◽  
Author(s):  
P. Cornel ◽  
B. Weber

Irrigation periods are usually limited to vegetation periods. The quality requirements for treated wastewater for disposal and for reuse are different. The reuse of water for irrigation allows partly the reuse of the wastewater's nutrients (N and P). Outside the irrigation period the water must be treated for disposal, thus nutrient removal is often required in order to avoid detrimental effects on the receiving surface water body. Only wastewater treatment plants with different operation modes for different seasons can realise these requirements. The nitrification is the most sensitive biological process in the aerobic wastewater treatment process. At low water temperatures the nitrifying bacteria need several weeks to re-start full nitrification after periods without NH4-removal. Therefore it is necessary to develop options for waste water treatment plants which allow a fast re-start of the nitrification process. Based on theoretical considerations and computer simulations of the activated sludge treatment process, one possibility for implementing a wastewater treatment plant with different seasonal operation modes is evaluated.


2017 ◽  
Vol 76 (12) ◽  
pp. 3278-3288 ◽  
Author(s):  
Zhenchao Zhang

Abstract In this study, a combined process was developed that included micro-electrolysis, Fenton oxidation and coagulation to treat oilfield fracturing wastewater. Micro-electrolysis and Fenton oxidation were applied to reduce chemical oxygen demand (COD) organic load and to enhance organic components gradability, respectively. Orthogonal experiment were employed to investigate the influence factors of micro-electrolysis and Fenton oxidation on COD removal efficiency. For micro-electrolysis, the optimum conditions were: pH, 3; iron-carbon dosage, 50 mg/L; mass ratio of iron-carbon, 2:3; reaction time, 60 min. For Fenton oxidation, a total reaction time of 90 min, a H2O2 dosage of 12 mg/L, with a H2O2/Fe2+ mole ratio of 30, pH of 3 were selected to achieve optimum oxidation. The optimum conditions in coagulation process: pH, cationic polyacrylamide dosage, mixing speed and time is 4.3, 2 mg/L, 150 rpm and 30 s, respectively. In the continuous treatment process under optimized conditions, the COD of oily wastewater fell 56.95%, 46.23%, 30.67%, respectively, from last stage and the total COD removal efficiency reached 83.94% (from 4,314 to 693 mg/L). In the overall treatment process under optimized conditions, the COD of oily wastewater was reduced from 4,314 to 637 mg/L, and the COD removal efficiency reached 85.23%. The contribution of each stage is 68.45% (micro-electrolysis), 24.07% (Fenton oxidation), 7.48% (coagulation), respectively. Micro-electrolysis is the uppermost influencing process on COD removal. Compared with the COD removal efficiency of three processes on raw wastewater under optimized conditions: the COD removal efficiency of single micro-electrolysis, single Fenton oxidation, single coagulation is 58.34%, 44.88% and 39.72%, respectively. Experiments proved the effect of combined process is marvelous and the overall water quality of the final effluent could meet the class III national wastewater discharge standard of petrochemical industry of China (GB8978-1996).


2001 ◽  
Vol 43 (2) ◽  
pp. 91-99 ◽  
Author(s):  
T. Iwane ◽  
T. Urase ◽  
K. Yamamoto

Escherichia coli and coliform group bacteria resistant to seven antibiotics were investigated in the Tama River, a typical urbanized river in Tokyo, Japan, and at a wastewater treatment plant located on the river. The percentages of antibiotic resistance in the wastewater effluent were, in most cases, higher than the percentages in the river water, which were observed increasing downstream. Since the possible increase in the percentages in the river was associated with treated wastewater discharges, it was concluded that the river, which is contaminated by treated wastewater with many kinds of pollutants, is also contaminated with antibiotic resistant coliform group bacteria and E.coli. The percentages of resistant bacteria in the wastewater treatment plant were mostly observed decreasing during the treatment process. It was also demonstrated that the percentages of resistance in raw sewage are significantly higher than those in the river water and that the wastewater treatment process investigated in this study works against most of resistant bacteria in sewage.


2015 ◽  
Vol 28 (10) ◽  
pp. 1305-1315 ◽  
Author(s):  
Xia Luo ◽  
Yun-Zhong Liu ◽  
Bin Wang

Sign in / Sign up

Export Citation Format

Share Document