scholarly journals DEVELOPMENT AND VALIDATION OF AN HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF 17-Β ESTRADIOL IN POLYMERIC NANOPARTICLES

Author(s):  
ADRIANA YURIKO KOGA ◽  
BRUNA CARLETTO ◽  
LEANDRO CAVALCANTE LIPINSKI ◽  
TRAUDI KLEIN ◽  
PAULO VITOR FARAGO

Objective: A simple high-performace liquid chromatography method was developed and validated to determine 17-β estradiol in poly (ε-caprolactone) nanocapsules. Methods: The chromatographic conditions were as follows: C18 GL column with a mobile phase of acetonitrile:water (92:8 v/v) at flow rate of 1.5 mL/min with detection at 280 nm. The evaluated parameters were specificity, linearity, limits of detection and quantification, precision, accuracy, and robustness. Results: The method was specific and linear (r=0.9982). The limits of detection and quantification were 5.78 μg.mL-1 and 17.54 μg.mL-1, respectively. Suitable accurancy and robustness were obtained. The stability assay showed that pH variation occured after 120 days of storage, and no changes were observed regarding the size and polydispersion parameters. The applicability of the method was evaluated by determining the encapsulation efficiency of the E2 nanocapsules after 120 days of storage. The results showed values >99%. Conclusion: The results demonstrated the applicability of the developed and validated analytical method.

INDIAN DRUGS ◽  
2017 ◽  
Vol 54 (01) ◽  
pp. 35-40
Author(s):  
A. S. Bagde ◽  
V. V. Khanvilkar ◽  

The present work describes a validated reverse phase high performance liquid chromatography (RPHPLC) method for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate in pharmaceutical dosage from. The drugs were resolved using Hemochrom Intsil C18-5U column (250×4.6) mm in isocratic mode with mobile phase methanol: water (0.08% diethylamine, 0.02% of glacial acetic acid and pH 4.4 adjusted with orthophosphoric acid) in the ratio of 70:30 V/V at a flow rate of 1.0 mL/min. Retention time of dextromethorphan hydrobromide and quinidine sulphate were 4.9±0.2 and 3.6±0.2, respectively, at 292nm. The above mentioned method was validated as per International Conference on Harmonization (ICH) guidelines. Linear responses were obtained in concentration ranges of 5-35 μg/mL for dextromethorphan hydrobromide and 4-16 μg/mL for quinidine sulphate, with correlation coefficient (r2) of 0.999 for both the drugs. A simple, selective, accurate, precise, robust and reliable RP-HPLC method thus developed and validated for simultaneous estimation of dextromethorphan hydrobromide and quinidine sulphate.


Sign in / Sign up

Export Citation Format

Share Document