scholarly journals Percutaneous Retrieval of a Misinserted Pigtail Catheter Straightener during Infra-Renal Abdominal Aortic Stenting: A Case Report

2020 ◽  
Vol 5 (3) ◽  
pp. 145-149
Author(s):  
Yuichiro Izumi ◽  
Shuji Ikeda ◽  
Akira Kitagawa ◽  
Yusuke Imaeda ◽  
Tetsuya Yamada ◽  
...  
Perfusion ◽  
2021 ◽  
pp. 026765912098677
Author(s):  
Chuntian Li ◽  
Xin Mao ◽  
Xu Zhao ◽  
Guiqing Liu ◽  
Gang Xu ◽  
...  

Middle aortic syndrome (MAS) is a rare disease characterized by distal thoracic aorta or abdominal aorta coarctation, and thoraco-abdominal aortic bypass grafting is an effective treatment for this condition. However, significant trauma is associated with the conventional surgical approach. We report a 26-year-old woman with MAS who presented with hypertension and needed thoraco-abdominal bypass grafting. In this operation, we adopted the endoscopic technique to improve the conventional surgical approach (reduce the incision). This case report shows that it is safe and feasible to use an endoscopic technique to reduce the trauma during this kind of operation, and provides a reference for similar treatments.


2021 ◽  
Vol 70 ◽  
pp. 102815
Author(s):  
Sarya Swed ◽  
Salim Tfankji ◽  
Hussein Alkanj ◽  
Tasneem Mohamed ◽  
Nawras Alhalabi ◽  
...  

1996 ◽  
Vol 51 (2) ◽  
pp. 140-143 ◽  
Author(s):  
R.D. Edwards ◽  
P.C. Rowlands ◽  
L.A. Armistead

2014 ◽  
Vol 29 (4) ◽  
pp. 192-196 ◽  
Author(s):  
Ramazan Yildiz ◽  
Muharrem Oztas ◽  
Mehmet Ali Sahin ◽  
Gokhan Yagci

Vascular ◽  
2021 ◽  
pp. 170853812110627
Author(s):  
Julian Smith ◽  
Simon Joseph ◽  
Catherine Thoo

Background The Zenith endovascular graft (Cook Medical, Bloomington, IN, USA) is a well-recognised device used in endovascular repair of abdominal aortic aneurysms (EVAR). After a small number of reported cases of suprarenal stent separation from the main body of the graft, modifications were made to the strength and durability of the suture line attachment of the proximal bare metal component prior to release in 2003. This report describes a further case of suprarenal stent separation and type IA endoleak in a patient who underwent an EVAR using the Zenith device in 2012. Methods We present a case report of a 77-year-old male with incidental finding of type IA endoleak on a background of elective endovascular repair for 50.4-mm infrarenal abdominal aortic aneurysm (AAA), with a Cook Zenith endograft. Computed tomography (CT) demonstrated separation of the suprarenal bare metal stent from the main body of the endograft, with resultant graft migration and increase in native aneurysm sac size. Results The patient underwent semi-urgent surgery with successful placement of a bridging thoracic stent graft between the lowest renal artery and main body of the pre-existing graft. Conclusions This case report describes a rare complication of Zenith devices, additionally emphasising the importance of regular surveillance imaging following EVAR.


2015 ◽  
Vol 30 (9) ◽  
pp. 1361 ◽  
Author(s):  
Jae Yeong Cho ◽  
Kye Hun Kim ◽  
Hyun Ju Yoon ◽  
Hyun Ju Seon ◽  
Youngkeun Ahn ◽  
...  

2018 ◽  
Vol 120 (4) ◽  
pp. 271-273
Author(s):  
Vedran Pazur ◽  
Inga Dakovic Bacalja ◽  
Ivan Cvjetko ◽  
Ana Borovecki