A Simple Method for Preparing Silver-Silver Chloride Electrodes for Recording of Skin-Potential

1966 ◽  
Vol 79 (2) ◽  
pp. 309 ◽  
Author(s):  
Reginald E. Quilter ◽  
Walter W. Surwillo
Nanomaterials ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1962
Author(s):  
Lingjun Li ◽  
Guangli Li ◽  
Yuliang Cao ◽  
Yvonne Yanwen Duan

High-definition transcranial direct current stimulation (HD-tDCS) is a promising non-invasive neuromodulation technique, which has been widely used in the clinical intervention and treatment of neurological or psychiatric disorders. Sintered Ag/AgCl electrode has become a preferred candidate for HD-tDCS, but its service life is very short, especially for long-term anodal stimulation. To address this issue, a novel highly durable conductive carbon/silver/silver chloride composite (C/Ag/AgCl) electrode was fabricated by a facile cold rolling method. The important parameters were systematically optimized, including the conductive enhancer, the particle size of Ag powder, the C:Ag:PTFE ratio, the saline concentration, and the active substance loading. The CNT/Ag/AgCl-721 electrode demonstrated excellent specific capacity and cycling performance. Both constant current anodal polarization and simulated tDCS measurement demonstrated that the service life of the CNT/Ag/AgCl-721 electrodes was 15-16 times of that of sintered Ag/AgCl electrodes. The much longer service life can be attributed to the formation of the three-dimensional interpenetrating conductive network with CNT doping, which can maintain a good conductivity and cycling performance even if excessive non-conductive AgCl is accumulated on the surface during long-term anodal stimulation. Considering their low cost, long service life, and good skin tolerance, the proposed CNT/Ag/AgCl electrodes have shown promising application prospects in HD-tDCS, especially for daily life scenarios.


1980 ◽  
Vol 58 (4) ◽  
pp. 323-327 ◽  
Author(s):  
Upendra Nath Dash ◽  
Uttam Kumar Nayak

The ionization constant, K, of trans-crotonic acid, and the first and second ionization constants, K1 and K2, of adipic acid have been determined in water at seven different temperatures ranging from 15 to 45 °C with the help of the cells without liquid junction using silver – silver chloride and quinhydrone electrodes. The variations of pK, pK1, and pK2 with temperature have been expressed by the equations[Formula: see text]and[Formula: see text]From the temperature coefficient of the ionization constants, the standard enthalpy, entropy, Gibbs energy, and heat capacity changes of the corresponding dissociation processes have been calculated. Using the values of ionization constants of adipic acid, the standard potential of the Ag(s)/Ag2Ad(s)/Ad2− electrode, and the related standard thermodynamic quantities for the electrode process[Formula: see text]have been calculated in water at those temperatures.


1964 ◽  
Vol 42 (6) ◽  
pp. 1315-1322 ◽  
Author(s):  
R. Srinivasan ◽  
S. N. Flengas

The electrode potentials of the system Th, ThCl4 (KCl, NaCl) were measured at various concentrations of thorium chloride, and at temperatures between 670 °C and 850 °C, using a silver – silver chloride reference electrode. It was shown by a direct gravimetric method that the reaction,Th(metal) + ThCl4(melt) = 2ThCl2(in melt),postulated by previous investigators, did not take place.The activity coefficients, and the other partial molal properties of the solutions of ThCl4, in the equimolar mixture of potassium and sodium chlorides, were calculated as a function of temperature from the e.m.f. measurements.


Sign in / Sign up

Export Citation Format

Share Document