scholarly journals Placement of Subcutaneous Ureteral Bypass without Fluoroscopic Guidance in Cats with Ureteral Obstruction

2020 ◽  
Vol 51 (2) ◽  
pp. 29-35
Author(s):  
Rina KIKUCHI ◽  
Katsuyuki FUJII ◽  
Yuto KAMIBAYASHI ◽  
Koudai TSUKAHATA ◽  
Manami SATO ◽  
...  
2016 ◽  
Vol 19 (10) ◽  
pp. 1030-1039 ◽  
Author(s):  
Véronique Livet ◽  
Paul Pillard ◽  
Isabelle Goy-Thollot ◽  
David Maleca ◽  
Quentin Cabon ◽  
...  

Objectives The purpose of this study was to describe the perioperative and postoperative complications as well as short-term and long-term outcomes in cats with ureteral obstructions treated by placement of a subcutaneous ureteral bypass (SUB) device without imaging control. The second objective of this study was to compare cats treated by SUB device with cats treated by traditional surgical intervention. Methods Data were obtained retrospectively from the medical records (2014–2016) of cats that underwent SUB placement (SUB cats) and cats that underwent traditional ureteral surgery (C cats). Results Nineteen SUB devices were placed without fluoroscopic, radiographic or ultrasonographic guidance in 13 cats. Fifteen traditional interventions (ureterotomy and neoureterocystostomy) were performed in 11 cats. Successful placement of the SUB device was achieved in all cats with only one major intraoperative complication (kinking of the kidney catheter) and one minor intraoperative complication (misplacement of the kidney catheter). Eleven SUB cats recovered from the surgical procedure; two SUB cats and three C cats died during the anaesthesia recovery period. Postoperative SUB complications included anaemia (n = 2), urinary tract infection (UTI) (n = 4), non-infectious cystitis (n = 5) and SUB device obstruction (n = 1). Postoperative traditional surgery complications included anaemia (n = 7), UTIs (n = 6), non-infectious cystitis (n = 1), re-obstruction (n = 4) and ureteral stricture (n = 1). Median postoperative duration of hospitalisation (3 days) was significantly shorter for SUB cats than for C cats ( P = 0.013). Ten SUB cats (76.9%) and four C cats (40%) were still alive at a median follow-up of 225 days and 260 days, respectively. Owners were completely (90%) or mostly (10%) satisfied with the SUB device placement. Conclusions and relevance SUB device placement appears to be an effective and safe option for treating ureteral obstruction in cats, and this study has shown that fluoroscopic guidance is not essential in all cases.


Author(s):  
P D Chakravarty ◽  
T Kunanandam ◽  
G Walker

Abstract Background Ingested foreign bodies are a common presentation to paediatric ENT services. Depending on the site, these are usually managed with flexible or rigid oesophagoscopy and retrieval. This paper presents a novel technique for removing a hollow foreign body that could not be removed using conventional means. Method and results After rigid and flexible approaches failed, a guidewire was passed through the foreign body under fluoroscopic guidance and a dilatation balloon passed through the lumen of the object. Inflating the balloon allowed dilatation of the inflamed mucosa above and below the object, facilitating straightforward removal under traction. Conclusion This is a novel and reproducible technique that uses equipment readily available in tertiary referral centres. Employed in this context, the technique enabled removal of an impacted object surrounded by granulation tissue, and would be appropriate for other objects with a lumen.


Sign in / Sign up

Export Citation Format

Share Document