Adhesive Bond Strengths to Enamel and Dentin Using Recommended and Extended Treatment Times

2010 ◽  
Vol 35 (1) ◽  
pp. 112-119 ◽  
Author(s):  
N. S. Kimmes ◽  
W. W. Barkmeier ◽  
R. L. Erickson ◽  
M. A. Latta

Clinical Relevance Self-etch adhesive systems are promoted as being more efficient for bonding procedures by using fewer treatment steps to condition tooth surfaces for bonding resin-based materials. Concern has been expressed regarding the ability of the newer self-etch adhesives to yield strong, durable bonds when compared to more traditional etch-and-rinse systems. Extending the treatment time of etch-and-rinse and self-etch adhesives does not appear to result in relevant increases in the bond strength of resin composites to enamel or dentin.

10.2341/07-63 ◽  
2008 ◽  
Vol 33 (2) ◽  
pp. 155-162 ◽  
Author(s):  
A-K. Lührs ◽  
S. Guhr ◽  
R. Schilke ◽  
L. Borchers ◽  
W. Geurtsen ◽  
...  

Clinical Relevance When using self-etch adhesives to bond composite materials to enamel, there is concern about the ability to achieve bond strengths comparable to approved etch-and-rinse systems. An additional phosphoric acid etching can improve the shear bond strength of self-etch adhesives to enamel.


2010 ◽  
Vol 35 (1) ◽  
pp. 84-93 ◽  
Author(s):  
M. E. Mcleod ◽  
R. B. T. Price ◽  
C. M. Felix

Clinical Relevance Despite recent improvements in self-etch bonding systems, a two-step etch and rinse system gave consistently higher shear bond strengths to both ground enamel and dentin and would be the best system to use clinically.


2011 ◽  
Vol 36 (1) ◽  
pp. 86-91 ◽  
Author(s):  
M. Schiltz-Taing ◽  
Y. Wang ◽  
B. Suh ◽  
D. Brown ◽  
L. Chen

Clinical Relevance The effectiveness of self-etch adhesive systems is dependent on both the physical properties of the adhesive and the integrity of the adhesive-dentin interface. Most importantly, the integrity of the adhesive-dentin interface is affected by the tubule orientation of the intaglio dentin structure. The initial bond strength and potential durability of the self-etch adhesive interfaces to dentin are significantly affected by both the adhesive pH and occlusally-oriented tubule direction. The clinical relevance to the dentist is that the results reported for bond strengths by both manufacturers and independent researchers should be interpreted and compared based on the orientation of the dentin used for the measurements, particularly for those adhesives that are very acidic (pH lower than 2).


2011 ◽  
Vol 36 (2) ◽  
pp. 213-221 ◽  
Author(s):  
S Kasraei ◽  
M Azarsina ◽  
S Majidi

Clinical Relevance The use of resin-modified glass ionomers as cavity liners in the closed-sandwich technique reduced microleakage in Class II composite restorations.


10.2341/05-55 ◽  
2006 ◽  
Vol 31 (4) ◽  
pp. 450-455 ◽  
Author(s):  
A. M. Guéders ◽  
J. F. Charpentier ◽  
A. I. Albert ◽  
S. O. Geerts

Clinical Relevance This study indicates that etch and rinse adhesive systems are less prone to microleakage than self-etch systems.


2017 ◽  
Vol 18 (1) ◽  
pp. 34-38
Author(s):  
Mojtaba Abdollahi ◽  
Masoumeh Ebrahimi ◽  
Alireza Sarraf Shirazi ◽  
Faraneh Abdolhoseinpour

ABSTRACT Introduction One of the possible mechanisms for the gradual destruction of bond strength in dentin-resin interface, could be due to the demineralized unstable collagen matrix. Use of protease inhibitors, such as tannic acid (TA) could prevent destruction of collagen fibers. The aim of this study was to compare the TA effect on bond strength of etch and rinse and self-etch adhesive systems in the dentin of primary teeth. Materials and methods This in vitro study was done on 40 extracted primary molar teeth. The teeth were sectioned in the mesiodistal direction, and enamel of buccal and lingual surfaces was removed. Samples were randomly divided into four groups: Single bond (SB) + TA, SB, Clearfil SE Bond (CSB) + TA, and CSB. Then, Z250 and Clearfil AP-X composites were cured on the surfaces of SB and CSB groups respectively. After that, all samples were divided into aging and non-aging groups. For 3 months, samples were placed under 1,000 thermal cycles in aging group. Subsequently, the shear bond strengths of all groups were measured by the International testing machine, and failure mode was evaluated by an optical stereomicroscope. Data were analyzed with paired t-test and independent t-test. Results Tannic acid induced a significant reduction in the immediate bond strength of adhesive SB. Meanwhile, TA had no significant effect on shear bond strength of the CSB system. Conclusion Based on our findings, use of TA is not recommended with SB and CSB adhesives on primary teeth. Clinical significance Tannic acid may not be considered in resin restorations of primary teeth. How to cite this article Ebrahimi M, Sarraf Shirazi A, Abdolhoseinpour F, Abdollahi M. Effect of Tannic Acid on Bond Strength of Etch and Rinse and Self-etch Adhesive Systems in Dentin of Primary Teeth. J Contemp Dent Pract 2017;18(1):34-38.


Marine Drugs ◽  
2020 ◽  
Vol 18 (5) ◽  
pp. 263 ◽  
Author(s):  
Eugenia Baena ◽  
Sandra R Cunha ◽  
Tatjana Maravić ◽  
Allegra Comba ◽  
Federica Paganelli ◽  
...  

The aim of the present study was to evaluate the effect of 0.1% chitosan (Ch) solution as an additional primer on the mechanical durability and enzymatic activity on dentine using an etch-and-rinse (E&R) adhesive and a universal self-etch (SE) adhesive. Microtensile bond strength and interfacial nanoleakage expression of the bonded interfaces for all adhesives (with or without pretreatment with 0.1% Ch solution for 1 min and air-dried for 5 s) were analyzed immediately and after 10,000 thermocycles. Zymograms of protein extracts from human dentine powder incubated with Optibond FL and Scotchbond Universal on untreated or Ch-treated dentine were obtained to examine dentine matrix metalloproteinase (MMP) activities. The use of 0.1% Ch solution as an additional primer in conjunction with the E&R or SE adhesive did not appear to have influenced the immediate bond strength (T0) or bond strength after thermocycling (T1). Zymography showed a reduction in MMP activities only for mineralized and demineralized dentine powder after the application of Ch. Application of 0.1% Ch solution does not increase the longevity of resin–dentine bonds. Nonetheless, the procedure appears to be proficient in reducing dentine MMP activities within groups without adhesive treatments. Further studies are required to comprehend the cross-linking of Ch with dentine collagen.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


10.2341/05-20 ◽  
2006 ◽  
Vol 31 (2) ◽  
pp. 240-247 ◽  
Author(s):  
F. H. O. Mitsui ◽  
A. R. Peris ◽  
A. N. Cavalcanti ◽  
G. M. Marchi ◽  
L. A. F. Pimenta

Clinical Relevance Bond strength is affected by the combination of thermal and mechanical load cycling. However, results vary greatly with the number of mechanical cycles and adhesive system type (total or self-etching).


Sign in / Sign up

Export Citation Format

Share Document