scholarly journals A Stability Indicating UV-HPLC Method for the Determination of Potential Impurities in Nandrolone Phenylpropionate Active pharmaceutical ingredient

2021 ◽  
Vol 59 (3) ◽  
pp. 405-417
Author(s):  
Amber Bharti
2017 ◽  
Vol 145 ◽  
pp. 248-254 ◽  
Author(s):  
Ana Silva Coelho ◽  
Clara Elisa Pontes Chagas ◽  
Rodrigo Maia de Pádua ◽  
Gerson Antônio Pianetti ◽  
Christian Fernandes

2010 ◽  
Vol 93 (3) ◽  
pp. 891-903 ◽  
Author(s):  
Jun Lu ◽  
Yu-Chien Wei ◽  
Robert J Markovich ◽  
Abu M Rustum

Abstract Loratadine is an important active pharmaceutical ingredient used in a wide variety of prescription and over-the-counter products for the treatment and relief of allergy symptoms. A novel stability-indicating gradient ion-pair RP-HPLC method for assay of loratadine and determination of both of its degradation compounds and process impurities has been developed. This method can separate loratadine from its eight structurally related compounds; it can also separate all of the related compounds from each other in less than 20 min. The stability-indicating capability of this method has been demonstrated by analyzing aged stability samples of loratadine. A 15 cm 4.6 mm id YMC-Pack Pro C18 HPLC column was the primary column and a 15 cm 4.6 mm id SunFire C18 column has been identified as an alternate (truly equivalent) column for this method. This gradient method uses mobile phases consisting of acetonitrile and an aqueous solution of 10 mM sodium acetate and 5 mM sodium dodecyl sulfate at pH 5.5. The new HPLC method was validated according to International Conference on Harmonization guidelines and proved to be suitable for routine QC use.


1970 ◽  
Vol 1 (3) ◽  
pp. 50-55 ◽  
Author(s):  
Aparajita Malakar ◽  
Bishwajit Bokshi

A simple, specific, accurate and stability-indicating high performance liquid chromatographic method was developed and validated for the determination of Epinastine Hydrochloride in pharmaceutical dosage form. The chromatographic conditions comprised of a reverse-phase, C18 column (150×4.6 mm), 5μm with a mobile phase consisting of a mixture of aqueous phase (3.8g of sodium pantanesulphonate monohydrate and 4.0g of potassium dihydrogen orthophosphate was dissolved in 1L of water and pH of solution was adjusted to 4.5 with o-phosphoric acid) and organic phase (acetonitrile and methanol was mixed in the ratio of 4:1 v/v) in the ratio of 60:40 v/v at a flow rate of 1.0ml/min. Detection was carried out at 220nm. The retention time of Epinastine Hydrochloride was found to be 3.5 min. The calibration curve was found linear between 2-200μg/ml. The percentage recoveries of Epinastine Hydrochloride were found to be in the range of 99.05-100.50%. The method was validated for accuracy, linearity, precision, detection limit, quantitation limit and robustness. The drug was subjected to acidic hydrolysis, basic hydrolysis, neutral hydrolysis, oxidation, photochemical and thermal degradation. All the peaks of degraded product were resolved from the active pharmaceutical ingredient with significantly different retention time. As the method could effectively separate the drug from its degradation product, it can be employed as a stability indicating one. Key Words: Epinastine hydrochloride; validation; stability indicating method; HPLC; dosage form. DOI: http://dx.doi.org/10.3329/icpj.v1i3.9662 International Current Pharmaceutical Journal 2012, 1(3): 50-55


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
J. Saroja ◽  
Anantha Lakshmi P.V. ◽  
Y. Rammohan ◽  
D. Divya Reddy

Abstract Background We describe a “stability-indicating liquid chromatography” technique for the estimation of dimethicone (DEC) and dicyclomine hydrochloride (DEH) in the established tablet formulations. Individual quantification of DEH and DEC was reported. But simultaneous quantification of DEH and DEC was lacking. DEH and DEC were analysed on an “XTerra C18 column (250 mm × 4.6 mm, 5 μm)” with the mobile phase solvent run isocratically with 0.1M K2HPO4-acetonitrile (55:45, v/v) on a flow speed of 1.0 mL/min. Results The chromatographic run period for the DEC and DEH assay was 6.0 min with retention times of 2.134 and 2.865 min, respectively. The method was validated for accuracy (99.453 to 100.417% and 99.703 to 100.303% recovery values for DEH and DEC, respectively), precision (RSV value 0.135% for DEC and 0.171% for DEH), linearity (5–15 μg/mL for DEH and 20–60 μg/mL for DEC), selectivity (no hinderance from excipients) and specificity (no hinderance from degradants) recovery. Conclusion The developed stability-indicating liquid chromatography process was well applied to established tablet formulations.